  1. Replies
    0
    Views
    380

    Straightening Aire-Sweep brush?

    I just bought a used abatement package B. Everything is great except the brushes. They are smash together and they look like sh**. I was wonder is there any way to straighten them? And it doesnt come...
  2. Replies
    3
    Views
    933

    Thanks for the number. I called that number...

    Thanks for the number. I called that number yesterday they said that they can send the form to my house but I told them I can go there to pick it up. I went to DLLR in Baltimore to pick it up and...
  3. Replies
    3
    Views
    933

    Maryland hvac form Help

    I am is an install tech and have had Maryland hvac apprentice for 7 years. I am trying to get my Maryland Journeyman license but I have no luck of finding the MD journeyman form. Please help me to...
  4. Replies
    12
    Views
    2,095

    first minutes fan runs at 50%. min 1 to 8 runs at...

    first minutes fan runs at 50%. min 1 to 8 runs at 80% then after that its runs at 100% full speed
  5. Replies
    6
    Views
    1,135

    Went to Roberts Oxygen and bought the adapter for...

    Went to Roberts Oxygen and bought the adapter for it
  6. Replies
    6
    Views
    2,708

    it is a variable speeds air handler. If yes then...

    it is a variable speeds air handler. If yes then I would recommended that you should keep fan on during the summer and keep the fan Auto during the winter.
  7. Replies
    6
    Views
    1,135

    I have both B tank and MC tank, but the acetylene...

    I have both B tank and MC tank, but the acetylene regulator doesn't fit either of them. The acetylene regulator inlet looks like the nitrogen regulator that have. I need the adapter for the acetylene...
  8. Replies
    6
    Views
    1,135

    Adaptor for Oxy Acetylene

    I have a MC tank & 20 cubic in. oxygen. I just bought a Oxy Acetylene kit online and try test it today. Little does I know that the adapter for the acetylene doesn't fit. The acetylen regulator has...
  9. Replies
    11
    Views
    1,155

    Yeah there are two that I know of and I'm...

    Yeah there are two that I know of and I'm installing mostly Trane. You either have to run additional wires of low voltage from Heat Pump to Furnace to thermostat(NO NEED FOR THE DUAL FUEL KIT) OR...
  10. Your furnace is a 90+ furnace, that model does...

    Your furnace is a 90+ furnace, that model does not have a window for you to see. Everything is close up, all you going to see is the red LED light.
  11. Dont get the communication XL16 because there is...

    Dont get the communication XL16 because there is too many problem that is why TRANE stop make them!!!! With the communication XL16 you would use T-Con900
  12. what is your furnace model?

    what is your furnace model?
  13. Replies
    8
    Views
    910

    replaced with a 36E55 221 and working perfectly

    replaced with a 36E55 221 and working perfectly
  14. Replies
    8
    Views
    910

    I am is an installer, I normally install Trane. I...

    I am is an installer, I normally install Trane. I not familiar with this White Rodgers gas valve that is why I ask for help. Gas valve is a 36E54-250. If I am not an installer how do I know about...
  15. Replies
    8
    Views
    910

    I change the orifices already back to #45 it were...

    I change the orifices already back to #45 it were #56
  16. Replies
    8
    Views
    910

    York Gas valve spring located

    Installing a York furnace that my friend gave me model P1XUB12V05501D. It is a 2 stages variable speed. It was previous converted to propane and now I am converting it back to gas. I have the spring...
  17. Replies
    6
    Views
    1,020

    water sitting in the panel. It depend on where you

    water sitting in the panel. It depend on where you
  18. Replies
    6
    Views
    1,020

    Under the house? its might freeze up

    Under the house? its might freeze up
  19. Replies
    8
    Views
    808

    How do u start up the system and charge them to...

    How do u start up the system and charge them to factory spec in A/C mode? That's why my company give away a summer check up if the we install A/C in the winter.
  20. Replies
    1
    Views
    808

    Fireplace insert

    I am is an HVAC installer, I have experience about fireplace insert. I am interested in buying a wood stove insert and want to know what would be a good insert that allows me to adjust the burning...
  21. Replies
    33
    Views
    11,105

    About 3 years ago, me and my partner worked at...

    About 3 years ago, me and my partner worked at this high end condo in :censored: , MD. We were to install temperature sensor to tell switch on furnace in every condo. Those condo had a lot of busted...
  22. Replies
    3
    Views
    766

    I've just talked to people in HVAC class and...

    I've just talked to people in HVAC class and found out that my fireplace is just for look. They told me that I need a wood stove insert, did a little research and found out that is what I need to...
  23. Replies
    3
    Views
    766

    addition to it I want to know if is should keep...

    addition to it I want to know if is should keep the glass door open or close
  24. Replies
    3
    Views
    766

    Starting fireplace

    Starting up my fireplace for the first time and it seem not put out any radiation heat at all. What did I do wrong and what are the advise and how to adjust the damper on it.
  25. Replies
    45
    Views
    4,493

    15 SEER + bigger evaporator coil boost it up to...

    15 SEER + bigger evaporator coil boost it up to 16 SEER


    If I am wrong may may I ask what brand do u service or install?
  26. Replies
    45
    Views
    4,493

    The main reason that you would want a bigger coil...

    The main reason that you would want a bigger coil evaporator coil is to boost the seer rating up to 16 seer in AIR CONDITIONING mode only. That is how you quality for tax credit. In A/C mode bigger...
  27. Thread: Duct works

    by natra911
    Replies
    4
    Views
    536

    I have been in this trade for six years

    I have been in this trade for six years
  28. Thread: Duct works

    by natra911
    Replies
    4
    Views
    536

    Duct works

    Ever since I started in this trade I've always learn how to make the transition by hand. Recently I switch company and they like to order transition, I have no idea how to order duct works. Is there...
  29. Replies
    1
    Views
    603

    new TRANE A/C 4TTX5049

    Intalled a TRANE furnace a/c coil before new year. Started up furnace system works fine. Outside temp was 35, I always check my work so I pushed in the a/c contactor compressor ran but the fan didnt....
  30. Replies
    2
    Views
    443

    Honeywell Pro-8000 Adapt Intelligent

    I have been installing TRANE for about 4 years with Honeywell Pro-8000. I never pay attention to the Adapt Intelligent. I know what it functions, I havent had any complain until recent that it runs...