  1. Replies
    7
    Views
    728

    ok thats what I need. Thank you. Ken

    ok thats what I need. Thank you.
    Ken
  2. Replies
    7
    Views
    728

    Ya thats what I figured but what do I do to...

    Ya thats what I figured but what do I do to prevent it? I thought the relay in the mech room would prevent this.
  3. Replies
    7
    Views
    728

    could you please explain that to me?

    could you please explain that to me?
  4. Replies
    7
    Views
    728

    please move to tech/tech

    please move to tech/tech
  5. Replies
    7
    Views
    728

    Primary bath fan bringing on a/c???

    Good evening. I went to a job today where the primary bath fan was wired to a switch in the hall way. That went to a relay in the mechanical room which then went to the R&G terminals on the furnace...
  6. Thread: rheem 13pjl

    by kenadiens
    Replies
    12
    Views
    1,906

    We won't even quote the cubes any more. If it's...

    We won't even quote the cubes any more. If it's gonna be Rheem it's gonna be a Prestige.
  7. Replies
    0
    Views
    483

    zonex distributor in Canada??

    Any one know of a zonex distr. in B.C,Canada.
    Thanks,
    Ken
  8. Replies
    10
    Views
    1,149

    out to lunch...

    I was thinking hi eff. and am totally wrong but can't figure how to edit my post. As soon as I posted I knew I screwed up. Sorry.
  9. Replies
    10
    Views
    1,149

    I believe the max termination seperation is 18"....

    I believe the max termination seperation is 18". Going off memory I don't have the installs infront of me.
  10. Thread: vacuum oil

    by kenadiens
    Replies
    25
    Views
    1,655

    Do you guys use copper lines or just your hoses?...

    Do you guys use copper lines or just your hoses? The specs call for copper but that doesn't seem practical to me. Sorry don't mean to Hi jack.
  11. Replies
    7
    Views
    1,205

    Got back to it this morning and check the...

    Got back to it this morning and check the settings. The ecto for cooling stages was on default. I changed to #1 and and all was good. Second compressor fired up and and SA went down to 47 RA was 70....
  12. Replies
    7
    Views
    1,205

    energy management system. Got it!!:) Thermostat...

    energy management system. Got it!!:)
    Thermostat controlled.
  13. Replies
    27
    Views
    3,908

    could it be that Y1 is your econo and your comp...

    could it be that Y1 is your econo and your comp isn't getting the call on Y2?
  14. Replies
    7
    Views
    1,205

    At the risk of sounding like an idiot. What is an...

    At the risk of sounding like an idiot. What is an EMS?
  15. Replies
    7
    Views
    1,205

    high pressure, power off, low pressure. I think I...

    high pressure, power off, low pressure. I think I might be on to something though. If the factory default was left in place. The Y1 would be the economizer, Y2 the #1 compressor and nothing for the...
  16. Replies
    7
    Views
    1,205

    lennox lgc 120...

    Second stage compressor won't come on unless reset button is pushed. Only error codes were 14, 82, 23, 24. Second stage comp. only comes on a couple times for about 3 minutes or so, then not again...
  17. Replies
    13
    Views
    1,080

    3 ton system. cfm came to 1250.

    3 ton system. cfm came to 1250.
  18. Replies
    13
    Views
    1,080

    No. My first thought was non condensables but not...

    No. My first thought was non condensables but not having my recovery tank or a new filter I figured I'de double check the other options and Air flow was number 2 on my list. It was smack on and I...
  19. Replies
    13
    Views
    1,080

    now there would be a surprise.

    now there would be a surprise.
  20. Replies
    13
    Views
    1,080

    Ya it is charged for 15 feet. The line with 90's...

    Ya it is charged for 15 feet. The line with 90's added was 17 feet.
  21. Replies
    13
    Views
    1,080

    It was a split system and Rheem will definately...

    It was a split system and Rheem will definately be getting a bill. I haven't seen it yet on a package unit.
  22. Replies
    13
    Views
    1,080

    Rheem/Weatherking factory over charged.

    Anyone have this happen to them. New install and the head pressure was bouncing around and ended up 475 vapour pres. was 115. These readings are in heat mode. 50 F OT. 65 RAT. subcooling was through...
  23. Replies
    10
    Views
    1,109

    Thank you rundawg for your help. Very much...

    Thank you rundawg for your help. Very much appreciated.
  24. Replies
    10
    Views
    1,109

    The heating requirement was 71000 btu.

    The heating requirement was 71000 btu.
  25. Replies
    10
    Views
    1,109

    Do you know if the cfm will go down to the 800...

    Do you know if the cfm will go down to the 800 range?
  26. Replies
    10
    Views
    1,109

    It's a 58sxc 080-gg series

    It's a 58sxc 080-gg series
  27. Replies
    10
    Views
    1,109

    this is an existing furnace which the home owner...

    this is an existing furnace which the home owner would like a H/P installed. There is no existing coil installed. After doing the heat loss/ heat gain a 2 ton is required for cooling. I'm hoping the...
  28. Replies
    10
    Views
    1,109

    carrier 58sxc080

    Having trouble finding the install instuctions for this unit. Can any one tell me what the rated cfm for the different speeds are.
    Thanks,
    Ken
  29. Replies
    30
    Views
    3,097

    I was with ya HVAC Wiz until the "Mic" part. What...

    I was with ya HVAC Wiz until the "Mic" part. What are ya thinking?
  30. Thread: rheem 13pjl

    by kenadiens
    Replies
    12
    Views
    1,906

    alright thanks for the tip.

    alright thanks for the tip.
  31. Thread: rheem 13pjl

    by kenadiens
    Replies
    12
    Views
    1,906

    Thanks guys. Do you have any tricks to repairing...

    Thanks guys. Do you have any tricks to repairing the leak in such a small line? The first repair cause an obstruction. Low pressure would drop off to 0 and kick out. And yes I did run Nitro.
  32. Thread: rheem 13pjl

    by kenadiens
    Replies
    12
    Views
    1,906

    rheem 13pjl

    I've had two of these in the past 6 months spring a leak where the equalizer tube meets it's female adapter entering the 3/4 line. The only comon factor is that they both had high head pressure...
  33. Replies
    2
    Views
    744

    attic furnaces...

    After reading the post by anmldr I got to wondering if having a high eff. furnace in the attic was a good idea. Wouldn't the condesate freezing be an issue?
    Ken
  34. Replies
    113
    Views
    7,652

    I would refer to my employer. I expect my...

    I would refer to my employer. I expect my employer to do their best to keep me working so I in turn do my best to get them work.
  35. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    My first trip to this job the RA temp was taken...

    My first trip to this job the RA temp was taken at the unit, if I recall correctly it wasn't too far off. I believe it was 67 or 68 F.
  36. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    Room temp was used. There is a 4 " fresh air...

    Room temp was used. There is a 4 " fresh air supply that is close to the unit(10 ') but like I said room temp was used. I do appreciate your insites on this.
  37. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    I'll maybe adjust the air flow tabs for a lower...

    I'll maybe adjust the air flow tabs for a lower speed to see what kind of affect it has on everything. Couldn't hurt I guess.
  38. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    12 degree TD, with 35 degree subcooling ? I know...

    12 degree TD, with 35 degree subcooling ?
    I know Markl it's making me nuts! I'm leaning towards a restriction. Should I hold off on dealoing with it until a/c season to get better readings then open...
  39. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    It's heating ok but only because the Aux kicks in...

    It's heating ok but only because the Aux kicks in to raise the SA to 130 F. Before they kick in it's only 82 F. Indoor temp is 70 ish.
  40. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    It shouldn't be It's a variable speed with the...

    It shouldn't be It's a variable speed with the tabs set for 1180 cfm. I haven't tried taking charge out yet.
  41. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    Any other thoughts???

    Any other thoughts???
  42. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    liquid line temp was 71 F.

    liquid line temp was 71 F.
  43. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    when I refer to 140 ish temp I'm referring to the...

    when I refer to 140 ish temp I'm referring to the temp of the suction line just after the service port at the h/p. The install manual says for 33 degrees OAT the I should be seeing 79/305 with 134 F...
  44. Thread: Nordyne h/p

    by kenadiens
    Replies
    30
    Views
    1,553

    Nordyne h/p

    Hello every one. I'm looking at a Nordyne ht4bd 036k h/p R410a. Suction pressure is 78, head pressure is 352. Suction line temp is 101 F outside air is 35 F and inside air is 70 F. I'm concerned...