Search:

Type: Posts; User: davem

Page 1 of 10 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    4
    Views
    401

    Make sure an SD card is installed in the FG20 -...

    Make sure an SD card is installed in the FG20 - without it, you won't be able to install the firmware onto the FG20.
  2. Replies
    13
    Views
    1,860

    That manual is great - thanks for posting that!...

    That manual is great - thanks for posting that! I'd always wondered where to set a JCI VAV controller for various box sizes - I've had a Titus sheet with the "cfm @ 1"w.c." figures for awhile, that...
  3. I agree with Dansky (if I grasp what he's...

    I agree with Dansky (if I grasp what he's saying): this is all on the Lutron guy. For instance, on a job I was just on, the Lutron guy setup with the panels on each floor with the IP address I...
  4. Replies
    8
    Views
    334

    The PNC post-dates my AAM experience by several...

    The PNC post-dates my AAM experience by several years - although I see you work straight for AAM, and I haven't been an SI for almost 10 years, any chance I could send you the point.bob file for...
  5. Replies
    8
    Views
    334

    Thanks for that - while mildly sentimental to...

    Thanks for that - while mildly sentimental to look at, it turned out that the disk didn't have such a utility - which keeps me in the hunt for how to drag out the points list from a Sage into a...
  6. Replies
    8
    Views
    334

    Groovy - thanks! For some reason I found a...

    Groovy - thanks! For some reason I found a SageMax 1.8 IP setup disk on my laptop, but not the Utility disk...funny the old crud we keep around...(and then need the instant we throw it away...)
  7. Replies
    8
    Views
    334

    A little AAM conversion help, please!

    I've got a customer who is going to remove a SAGE from an end-user's facility, and replace it with a JACE. Having done several of these over the years, I know exactly what he needs to do to make a...
  8. Replies
    3
    Views
    276

    I think incontrol is looking for the information...

    I think incontrol is looking for the information to be available on the logic wiresheet, not necessarily a px page - that was a very handy feature of r2 wiresheets...
    What you need to do is...
  9. Replies
    14
    Views
    1,016

    That might be where you are slightly off-course -...

    That might be where you are slightly off-course - you won't be using the Program Service for this replace function:
    Make sure you're in Niagara Network>your JACE>Points>your new folder...that's...
  10. Replies
    14
    Views
    1,016

    Incontrol, you must be missing a step, because...

    Incontrol, you must be missing a step, because this process works perfectly...

    Make sure when you open the rtu4 folder, you then select all its points, then Edit. When the Edit dialog opens up,...
  11. Replies
    5
    Views
    334

    Mmelillo beat me to it - yes, I recommend option...

    Mmelillo beat me to it - yes, I recommend option 3, as it makes the temperature widgets a little more controllable (if you were to animate the Visible slot, as in option 1, and the binding condition...
  12. Replies
    5
    Views
    334

    Now that I've re-read the post, I see that I...

    Now that I've re-read the post, I see that I answered your first version of the question ("...based on the status of the controller...), but changing the image based on the reliability of the zone...
  13. Replies
    5
    Views
    334

    The Bound Label Binding's "ord" will be the...

    The Bound Label Binding's "ord" will be the pointer to the controller object (e.g. "station:|slot:/Drivers/BacnetNetwork/FPB_11_04"). Then, right-click "image", and select "Animate". Because of the...
  14. Replies
    3
    Views
    309

    While a similar calibration offset is found...

    While a similar calibration offset is found within Spyders, the OP needs not to calibrate his sensors, but configure the Spyder for a completely different sensor type.

    Since a Spyder doesn't...
  15. Replies
    29
    Views
    1,487

    Kinda pricey, but I've borrowed a Magbench a few...

    Kinda pricey, but I've borrowed a Magbench a few times (enough to get the boss to buy one for me) - there's always some metal to stick it to, whether in an electrical room or on a rooftop. ...
  16. Replies
    7
    Views
    425

    Do you have your heart set on the "Delta"-style...

    Do you have your heart set on the "Delta"-style enclosure? Kele sells a couple different styles of empty room sensor enclosures - you might find that their WMB-4 is a little more modern looking, and...
  17. Thread: TStat

    by davem
    Replies
    4
    Views
    274

    Honeywell T7350M has the outputs you need - well,...

    Honeywell T7350M has the outputs you need - well, except for that 2-15 volts...the stat delivers 4-20mA, which you'd need to convert to the voltage you need...
  18. Replies
    25
    Views
    2,637

    And there's the problem - for as nice as the...

    And there's the problem - for as nice as the Johnson stuff is, it absolutely doesn't play well on the same MS/TP trunk as other manufacturers. Figure out how to put the JCI stuff on their own trunk,...
  19. Hey, that's faster and easier!

    Hey, that's faster and easier!
  20. Use the Program Service to locate all...

    Use the Program Service to locate all history/NumericIntervalHistoryExt, and edit the property "enabled" slot to true.
  21. Replies
    8
    Views
    619

    And Y2K didn't garf the calendar!!

    And Y2K didn't garf the calendar!!
  22. Replies
    2
    Views
    283

    Yep - you'll have no problem seeing the CSC's,...

    Yep - you'll have no problem seeing the CSC's, and getting great gobs of points off of them - their validity depends on the CSC's configuration, of course, but you'll have no problem with the driver...
  23. Okay, but you better remove that email address...

    Okay, but you better remove that email address post haste, or the mods are gonna remove it for you...
  24. Replies
    7
    Views
    307

    Yeah, that's the feeling I'm getting - thanks for...

    Yeah, that's the feeling I'm getting - thanks for the input.
  25. Replies
    7
    Views
    307

    Well yeah, that kinda sorta does the N2 side, but...

    Well yeah, that kinda sorta does the N2 side, but what about the various GPL process setpoints, etc. that aren't N2 points? Or am I missing something? While keeping the NCM's in play for now is a...
  26. Replies
    7
    Views
    307

    NCMs into AX possible?

    It's been a few years since this topic saw any activity on this forum, so instead of resurrecting an old thread, I thought I'd renew the question:

    Has anyone developed an N1 driver solution...
  27. Replies
    7
    Views
    415

    I doubt that Obix is the solution theoldman is...

    I doubt that Obix is the solution theoldman is looking for, since that would leave the r2 JACE in place, which isn't a good long-term solution...plus, selling a Tridum-to-Tridium integration would...
  28. I tried to attach the handy spreadsheet I use to...

    I tried to attach the handy spreadsheet I use to calculate the linear scale and offset for inputs and outputs, but can't attach an xlsx, xls, or csv...so I'll just give you the answers:

    For...
  29. Replies
    6
    Views
    314

    Did you remember to change the dipswitches on the...

    Did you remember to change the dipswitches on the comm board as well? If memory serves (the document is somewhere on my other laptop...), dipswitch 1 is up, 2 and 3 are down. Be aware that the...
  30. Thread: AAM bus

    by davem
    Replies
    13
    Views
    551

    I completely agree with everything stated - the...

    I completely agree with everything stated - the idea of using 4/C cable certainly isn't a technically-supported one, and the fact that it has "worked" on a few occasions is in no way an endorsement...
  31. Thread: AAM bus

    by davem
    Replies
    13
    Views
    551

    I'm almost afraid to chime in here, given how...

    I'm almost afraid to chime in here, given how quickly the discussion turned to contractor skill...but I know exactly what happened here, as you described something I've run across a thousand times...
  32. Well, how cool is that? I was being more than a...

    Well, how cool is that? I was being more than a little facetious, being well aware of what a ridiculous task it would be to disconnect all the controllers, just to find the length of the...
  33. Yeah, I really think Marc has it right - the...

    Yeah, I really think Marc has it right - the length of the cabling be determined by an ohm-meter only if the network is completely powered-down (and provided the entire daisy-chain is comprised of...
  34. Replies
    4
    Views
    518

    There's a couple things that might trip you up,...

    There's a couple things that might trip you up, if you wanted to go down the path of removing the BCU's to replace them with JACE's...

    1) The Intellipaks might be Comm3, but if they contain the...
  35. Replies
    2
    Views
    232

    Have you tried this? I've used it successfully on...

    Have you tried this? I've used it successfully on several occasions, on everything from a failed upgrade to a fresh-out-of-the-box DOA JACE.
  36. Replies
    3
    Views
    330

    It looks like I couldn't change the text like I...

    It looks like I couldn't change the text like I thought on a new MultiValue Network Input...but I was able to specifically do what the original post asked: when building a hybrid activity, the Select...
  37. Replies
    3
    Views
    330

    I believe that if you select States(x) for your...

    I believe that if you select States(x) for your Enum set, and expose them to BACnet (which is a strange requirement, but crucial for customization), you will then be able to input custom state text...
  38. Replies
    10
    Views
    853

    Once the BACnet Server license feature has been...

    Once the BACnet Server license feature has been purchased (and the license file updated), you go into the BACnet driver's Local Device, and build its Export Table by discovering any points elsewhere...
  39. Replies
    19
    Views
    2,796

    Well, that was a strange one...finally found the...

    Well, that was a strange one...finally found the solution (although this thread is over a year old, so I'm really just talking to myself here...):
    Comm4 addresses have to start at 37, so even...
  40. Replies
    19
    Views
    2,796

    Is the vintage of the comm card really the issue...

    Is the vintage of the comm card really the issue why an Intellipak might not talk Comm4? I've got about 25 Intellipaks, all the same vintage from the 90's sometime, that don't want to communicate on...
  41. Replies
    11
    Views
    1,099

    Trane uses 10K Type 2.

    Trane uses 10K Type 2.
  42. As an integrator that doesn't perform the...

    As an integrator that doesn't perform the physical installations, but subcontracts those out to electrical contractors, we have found a couple well-qualified electrical contractors that specialize in...
  43. Thread: EasyIO LCD jar

    by davem
    Replies
    2
    Views
    517

    Wow, somebody gets up early there...I've got it...

    Wow, somebody gets up early there...I've got it now. Ridiculously easy to set up, now that I see the documentation...
  44. Thread: EasyIO LCD jar

    by davem
    Replies
    2
    Views
    517

    EasyIO LCD jar

    We've sold an EasyIO LCD display to one of our contractors, but can't seem to find the easyIOLCD jar file that supports its communication with a Niagara station - does anyone have that jar file to...
  45. Replies
    2
    Views
    259

    I monitor research freezers all the time with low...

    I monitor research freezers all the time with low temperature transmitters from ACI:
    http://workaci.com/sites/default/files/high%20and%20low.pdf. I prefer to use their remote probe (RP) option.
    ...
  46. Replies
    2
    Views
    471

    I've done both - the LONworks interface was quite...

    I've done both - the LONworks interface was quite easy to use, and the BACnet one just a little more complicated, but not bad either; there are a couple gotchas (like enabling the Ethernet port on...
  47. Replies
    5
    Views
    575

    I've gone through a lot of effort on...

    I've gone through a lot of effort on Tridium-over-AAM jobs to ensure that the customer knows to click the checkbox I provide for the outputs, to put them into manual, before issuing an override...I...
  48. Replies
    5
    Views
    575

    Arcane little Auto-Matrix alarm

    I know there's some good AAM techs still out there...hopefully somebody has some documentation that I don't...

    I have a GX1 running an internal SPL program, which is periodically aborting with an...
  49. Replies
    10
    Views
    1,354

    Absolutely correct - once the point is exported...

    Absolutely correct - once the point is exported from the BACnet Export Table, you can modify the points defined as writable from other devices or software. Just be sure to write to points at the...
  50. Replies
    2
    Views
    898

    We've used a line of PLC's called Cimon - they...

    We've used a line of PLC's called Cimon - they are built by KDT out of Korea http://www.kdtsys.com/eng/. They have a full redundancy system (power supplies and CPU) that we've successfully deployed...
Results 1 to 50 of 484
Page 1 of 10 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event