    trouble with older heil furnace

    having trouble with older 1992 heil furnace with honeywell spark to pilot.furnace comes on for a min,then shuts off before thermostat reaches temp,blower still runing for a min,then burners fire up...
  2. Thread: goodman gsc

    by dan927
    Replies
    1
    Views
    621

    goodman gsc

    what do you guys think of the goodman gsc r22 condenser?worth buying or pay a little more for the gsx 410a?
  3. Thread: 410a preasures

    by dan927
    Replies
    2
    Views
    537

    410a preasures

    what are typical low and high side preasures on a 80 degree day on a 14 seer 410a unit with a txv?
  4. Replies
    8
    Views
    3,851

    Refrigerant lineset copper fittings

    Is there realy any difference between plumbing and refrigerant copper elbows,couplings etc?I know that plumbing tube is sized by its inside diameter and acr tube by its outside diameter and a 3/4...
  5. Replies
    6
    Views
    1,423

    best refrigerant recovery unit

    need a new recovery unit.looking at yellow jacket recoverxlt or promax h93-074.
  6. Replies
    7
    Views
    1,057

    Refrigerant leak detector

    Whats a good electronic refrigerant leak detector thats not to expensive?
  7. Replies
    9
    Views
    1,194

    A coil cleaning tips

    Had a call today where the limit was shuting down furnace because of clogged A coil.Coil was very hard to get at for cleaning.Sitting right on top of furnace.any one have coil cleang tricks they...
  8. Replies
    4
    Views
    1,123

    only a 2 flat apartment building,gas pipe was...

    only a 2 flat apartment building,gas pipe was there,just wondering if its worth the time efort to change it two 3/4.supply pipe from meter is 1 inch.only the two supply takoffs for stove and furnace...
  9. Replies
    4
    Views
    1,123

    under sized gas pipe

    Furnace in second floor apartment has 1/2 gas supply pipe.Stove in kitchen also has 1/2 gas supply.Furnace is only 45000 btu.Can the 1/2 gas pipe going up 12 feet from basement supply enough gas to...
  10. Thread: fan inducer

    by dan927
    Replies
    2
    Views
    652

    fan inducer

    What do you techs do when you have a bad inducer on a nite call and you dont have one on your truck and supply house is closed?
  11. Replies
    7
    Views
    2,376

    goodman gks 92% furnace

    What do you people think of the goodman gks 92% furnace.pros and cons.