Search:

Type: Posts; User: farmer j

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    28
    Views
    4,097

    do thing should try to adjust expansion valve or...

    do thing should try to adjust expansion valve or replace
  2. Replies
    28
    Views
    4,097

    hello guys thanks for the real replys.rechecked...

    hello guys thanks for the real replys.rechecked compressor today,oil sight glass was full,pumped down,removed 7oz oil,level at 3/4 sight glass now.pressure38 psi 231psi,70 degrees outside temp,inside...
  3. Replies
    28
    Views
    4,097

    hello guys thanks for replys.background the...

    hello guys thanks for replys.background the company that i now own for 2 years has been working at this store for 20 years.compressor was origanal 502,compressor was changed years ago converted to...
  4. Replies
    28
    Views
    4,097

    copeland compressor not pumping freon

    copeland compressor m#3ra1-031a-tac-800 replaced old one 7-19-10 low side not pulling down,leaking valve plate? 11-1-10 compressor not pumping freon running 4.9 amps,oil foaming in sight glass,unit...
  5. Thread: 2 door cooler

    by farmer j
    Replies
    16
    Views
    1,657

    thanks 76 and guys with real answers.ordered cap...

    thanks 76 and guys with real answers.ordered cap tube from manufactor.replaced cap tube,drier,pulled vacuum,removed high side hose,charged 15oz freon 134a through low side.yes freon thats what we...
  6. Thread: 2 door cooler

    by farmer j
    Replies
    16
    Views
    1,657

    thanks guys with REAL answers.ordered cap tube...

    thanks guys with REAL answers.ordered cap tube from master built,i think somebody just put a cap tube on it,found out through manufactor that cooler used at cvs pharmacy,box was bought after katrina...
  7. Thread: 2 door cooler

    by farmer j
    Replies
    16
    Views
    1,657

    2 door cooler

    two door cooler
    14oz 134a
    check cooler on sat,running 1 psi-115psi.somebody had replaced cap tube,pressure with nitrogen to 300psi,no leaks found,blow through cap tube no restricion,recharge 16oz...
  8. Replies
    14
    Views
    761

    who dat who dat

    who dat who dat
  9. Replies
    4
    Views
    624

    new ice-o-matic

    ice-o-matic m#gem650a .installed new machine on top of fountain machine.makes ice good.ice is clumping together and not coming out.went back and adjusted water float to make ice dryer.worked better...
  10. Replies
    26
    Views
    1,292

    kentwood louisiana

    kentwood louisiana
  11. Thread: jordon cooler

    by farmer j
    Replies
    1
    Views
    775

    does anyone know where to find parts for a jordon...

    does anyone know where to find parts for a jordon cooler-sandwich prep box condenser fan out,plastic fan blade broke
  12. Thread: ruud heater

    by farmer j
    Replies
    4
    Views
    715

    I HAVE WENT TO AC SCHOOL,HAVE BEEN WORKING...

    I HAVE WENT TO AC SCHOOL,HAVE BEEN WORKING AC&REFRG 10 YEARS IN LOUISIANA NEVER SEEN A CONDENSING FURNACE BEFORE
  13. Thread: ruud heater

    by farmer j
    Replies
    4
    Views
    715

    ruud heater M#ugta-12erajs S#eh5d707f439703611...

    ruud heater M#ugta-12erajs S#eh5d707f439703611 found burners rusted out,burnt wires,burnt rollout switchs---replaced burners,switchs heater light up correct except top two chambers flame rolled...
Results 1 to 13 of 53
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event