  1. cap tube

    cap tube
  2. Replies
    31
    Views
    1,430

    the H-10 I have is a rechargeable battery its...

    the H-10 I have is a rechargeable battery its been super effective . I'm two years into the service trade and the h-10pm was supplied in the truck all the guys i work with have them. after a few...
  3. if that unit is sitting on the ground ( which it...

    if that unit is sitting on the ground ( which it looks to be) it doesn't really matter, there is no chance of it overflowing the pan and leaking into the structure
  4. Replies
    22
    Views
    2,132

    yeeehaw! cha ching cha ching$$. thats the sound...

    yeeehaw! cha ching cha ching$$. thats the sound of their wallet :yes:
  5. Replies
    12
    Views
    546

    I don't know. I was confused and thats why i...

    I don't know. I was confused and thats why i posted this thread. maybe i messed up somewhere not sure...
  6. Replies
    12
    Views
    546

    its a package unit so its weighed in charge. my...

    its a package unit so its weighed in charge. my first thought was it was a little low on gas but why would my SST be higher than what it should be? and compared to the other unit on the roof...
  7. Replies
    12
    Views
    546

    thats a good idea i didn't think of that.

    thats a good idea i didn't think of that.
  8. Replies
    12
    Views
    546

    SST was 55f which i also thought was high....

    SST was 55f which i also thought was high. superheat was 30 degrees so if valve was wide open then that wouldn't have been the case. and yes it was hot inside building.
  9. Replies
    12
    Views
    546

    txv troubleshooting

    Need some pointers on.the subject. Went to.a call.last week unit has high.superheat 30 and 9 degrees sub cool. Sst was 55 and head pressure was around 350 with a 90 degree ambient. R410a. I condemed...
  10. my thoughts exactly

    my thoughts exactly
  11. one p trap just wasn't good enough, i guess...

    my coworker installed this last week and i got a call today (sunday) because water was leaking into the ceiling and onto the floor. he claimed he didn't remember what store it was but he knew he made...
  12. hoshizaki and i believe manitowoc offer factory...

    hoshizaki and i believe manitowoc offer factory training schools that are like a week long in some facility where you work on machines and learn all diagnostics and such. not cheap though
  13. Replies
    6
    Views
    243

    thanks !

    thanks !
  14. Replies
    6
    Views
    243

    yes I've installed numerous mini splits. Im a...

    yes I've installed numerous mini splits. Im a tech notice the "professional member" tag under my name...? never been the one who does a site visit and calculation thats why i was asking how to go...
  15. Replies
    6
    Views
    243

    sizing a mini split

    How do i go about sizing a mini split for a house? my fiancees parents are thinking about putting one in their house and they asked me if i wanted to make some extra money installing it for them. i...
  16. Replies
    51
    Views
    2,560

    I have had Digicool ak900's for like 8 months or...

    I have had Digicool ak900's for like 8 months or so and have no complaints. like mentioned above durable, water resistant. I bought mine from tru tech tools and their costumer service is really good
  17. fluke

    fluke
  18. Replies
    23
    Views
    1,084

    i was waiting for someone to bring this up....

    i was waiting for someone to bring this up. although i have not heard details of the problem. who knows..? my boss would've had me there asap at least trying to resolve the issue lol unless it was...
  19. Replies
    17
    Views
    816

    :yes:

    :yes:
  20. Replies
    39
    Views
    1,721

    Ice, how do find these performance charts for...

    Ice, how do find these performance charts for compressors? I've searched for them and can't find them.
  21. Replies
    39
    Views
    1,721

    id have to agree with icemeister that seems like...

    id have to agree with icemeister that seems like the most logical and scientific way to troubleshoot a weak comp.
  22. Replies
    17
    Views
    816

    I change oil every time. i used to not be so...

    I change oil every time. i used to not be so dilligent. i work on refrigeration and a/c doing service. I have noticed my pump is more effective with the clean oil.
  23. Replies
    11
    Views
    654

    where are you selling them? you going to a...

    where are you selling them? you going to a festival or something?
  24. Replies
    3
    Views
    207

    thats not entirely true... you can use cap tube...

    thats not entirely true...
    you can use cap tube sizing charts and determine the length you need of a certain diameter cap tube you have depending on compressor horsepower, evap temp, how many feeds,...
  25. Replies
    10
    Views
    1,019

    most maybe.... but emerson does not...

    most maybe.... but emerson does not...