    With the incoming air at 63 Deg F and say 3 kW of...

    With the incoming air at 63 Deg F and say 3 kW of strip heat (not sure how much you actually have, I'm approaching the question theoretically) the rise only goes to less than 80 deg on 600 CFM. That...
  2. Replies
    2
    Views
    670

    That open floor plan would work well with...

    That open floor plan would work well with displacement ventilation. Uses less power, requires a lower delta T, is quiet, low velocity, very good for IAQ, works well in high roof buildings with open...
  3. Replies
    9
    Views
    489

    What you are describing is an ESCO, Energy...

    What you are describing is an ESCO, Energy Service Co, large corporate and institutional clients are well suited to ESCOs. For instance, when an ESCO finances solar panels at a sports arena. ...
  4. Is the system new or old? Has it done this in...

    Is the system new or old? Has it done this in the past or is it a new development?

    Has there been recent changes to the usage in the building either in the rooms served by the units or...
  5. Replies
    23
    Views
    1,510

    Have you considered VRF system for the entire...

    Have you considered VRF system for the entire building? No need for additional zoning equipment. Controller options can be pretty extensive including commercial protocols or standalone controllers....
  6. Ah. I was thinking the same thing. Many...

    Ah. I was thinking the same thing. Many disconnects are not even fused, but bypassing them is dangerous and potentially deadly.

    Find the guy and whap his head good.
  7. If you do not have energy recovery units and use...

    If you do not have energy recovery units and use a large amount of outdoor air due to occupancy and it is not used for makeup for processes or other forms of exhaust and is merely relieved, then CO2...
  8. If you don't mind a degree or two higher temp,...

    If you don't mind a degree or two higher temp, you can save more by just raising the cooling temp a couple of degrees and keeping it constant. (Not above 80, DX equipment doesn't like return temps...
  9. Thanks for your well reasoned response. ...

    Thanks for your well reasoned response.

    Believe it or not, I do have experience in the Houston area. I worked for a multinational corp with offices in Houston and engineered a project there a few...
  10. Correct.

    Correct.
  11. The OP sought...

    The OP sought Advice-for-a-High-Performance-New-Construction-in-Houston.

    In response to that we could have said add a roof venting system designed to induce draft and pull outside air through a...
  12. A 36,000 output btuh Unico chiller pulls 19 Amps...

    A 36,000 output btuh Unico chiller pulls 19 Amps at 208/230v/1 plus 560 watts for the pump. A 14 SEER condenser pulls about 23 amps at 208/230v/1. So far I'm not seeing the big deal?
  13. We had a lot of system volume contributing as...

    We had a lot of system volume contributing as well. We used oversized 2" headers all through the 1st floor and had quite a length of run outs (light institutional project). I think it was about a 30...
  14. If I remember correctly, the equipment costs are...

    If I remember correctly, the equipment costs are similar for equally sized VRF and mini chiller, but the mini chiller sales guy claimed lower installation costs, especially if PEX piping is used.
    ...
  15. You might notice that I keep mentioning equipment...

    You might notice that I keep mentioning equipment diversity as a potential for cost savings with the mini chiller setup. I had a high mass building with 18" thick uninsulated walls that I designed a...
  16. Fresh air should go through the AHU or a...

    Fresh air should go through the AHU or a dehumidifier first to condition it before it hits the space. A slight positive pressure helps keep infiltration rates down. Infiltration is outside air that...
  17. Good post here. I've used MultiAqua in...

    Good post here. I've used MultiAqua in commercial setting. The smallest heat pump they had when I used it was 5 tons, but they have smaller air cooled chillers (cooling only). Buffer tank is a...
  18. Glad to hear you are considering the solar. Lots...

    Glad to hear you are considering the solar. Lots of advantages in new construction to keep the cost more reasonable. 30k for 6 kW isn't too bad.

    I think you may lose too much efficiency using...
  19. You can do better. Probably lowest first cost...

    You can do better. Probably lowest first cost option though.



    In tight, well insulated construction this is worth considering. Have you considered Photovoltaic Solar panels to offset utility...
  20. To answer the OP question. Yes you can likely...

    To answer the OP question. Yes you can likely get a less restrictive register/grille. One with 0 or 22 deg def and the same blade count or one with larger blade spacing and lower blade count or any...
  21. Replies
    30
    Views
    1,834

    Since the unit is so close, that could be machine...

    Since the unit is so close, that could be machine noise from the unit. Reducing the unit to better match the load could improve that. Making a larger opening might not, so holding off on that is...
  22. Replies
    30
    Views
    1,834

    How's the noise level when the system is running?...

    How's the noise level when the system is running? Do you hear air noise (hiss) from the register? Everyone saying that it should be noisy at correct CFM for 4 tons are right. It would run about 35...
  23. Replies
    30
    Views
    1,834

    The man said it worked for 33 years. He didn't...

    The man said it worked for 33 years. He didn't say it was efficient or quiet. A 10 x 30 duct can handle 1600 cfm at .062 inch per 100 ft of ESP. So if it's going 10 feet or 3x that, 30 ft, for...
  24. Replies
    30
    Views
    1,834

    Is there a forced power vent on the water heater...

    Is there a forced power vent on the water heater and the furnace? Power venting increases the capacity allowed through the vent. Also the vent material makes a difference. Since it was used in...
  25. Replies
    7
    Views
    1,151

    Yup, big a$$ trap. In a blow through coil it...

    Yup, big a$$ trap. In a blow through coil it should work.