  1. Thread: R-410a split

    by heykiss
    Replies
    8
    Views
    669

    It was 83 deg. out during start up. Ran in june...

    It was 83 deg. out during start up. Ran in june when it was low 90's. Tripping w/ 77 deg. o.a. Maybe the cond. coil was dirtier than I thought.
  2. Thread: R-410a split

    by heykiss
    Replies
    8
    Views
    669

    R-410a split

    I consider myself a knowledgable mechanic, but I don't understand this one... I installed a 13 seer (Goodman indoor & outdoor coils) 2 ton split w/ t.x.v. 2 summers ago. The system ran w/outdoor amb....
  3. Replies
    16
    Views
    1,585

    The suction pressure is at its lowest at the...

    The suction pressure is at its lowest at the compressor inlet due to press. drop thru piping, which will cause first signs of frost when suction temp. gets less than 32 deg.
  4. Replies
    9
    Views
    2,995

    Most of the time, you get what you pay for.

    Most of the time, you get what you pay for.
  5. Replies
    19
    Views
    2,831

    Why would anyone want to pay a $1 a day in elec....

    Why would anyone want to pay a $1 a day in elec. to run a fan + taco 007 when you can run just the 007 for 10 cents a day ?
  6. Replies
    5
    Views
    2,422

    Oops, sorry K.

    Oops, sorry K.
  7. Replies
    5
    Views
    2,422

    The samsung units are wired different than the...

    The samsung units are wired different than the Mitsu. or sanyo. I believe you run (5) 14 guage conductors between the indoor & outdoor units, w/ 240 power(2 hots & ground from breaker). No neutral.
  8. Replies
    47
    Views
    5,138

    First of all, that is not a heat pump and the...

    First of all, that is not a heat pump and the accumulator was added to the system for flood back problems (look at weld drip). Most obvious, if you could spin back the accum. to its original...
  9. Replies
    46
    Views
    3,156

    4 Janitrol, 5 Bryant?

    4 Janitrol, 5 Bryant?
  10. Replies
    24
    Views
    5,547

    Those Cutler-Hammer contactors are garbage. I...

    Those Cutler-Hammer contactors are garbage. I guess it belongs on that unit.
  11. Replies
    28
    Views
    4,826

    Looks like it used to be a school, fire escape...

    Looks like it used to be a school, fire escape was code for kids in area, but now it's a condo building and they can do this. Still shouldn't be allowed. Could have saved a life.
  12. Replies
    12
    Views
    987

    We had to replace a coil that wasn't cleaned...

    We had to replace a coil that wasn't cleaned right, one year, and the pollen with coil cleaner solution hardened in the middle. The coil design on carriers plain suck. Plus, if you face the coil away...
  13. The compressor oil is probably 75% refrig. mix,...

    The compressor oil is probably 75% refrig. mix, causing low sub-cooling.
  14. Replies
    29
    Views
    2,300

    What's your head pressure? Is there a t.x.valve?...

    What's your head pressure? Is there a t.x.valve? Sounds overcharged to me.
  15. Replies
    17
    Views
    3,336

    Come on, get the copper changed out!

    Come on, get the copper changed out!
  16. Replies
    5
    Views
    855

    I would just go with a scroll compressor that can...

    I would just go with a scroll compressor that can start with high differential pressures if starting from scratch. I also can see why motor windings may break down with years of high torque starts,...
  17. Thread: Vacuum Time

    by heykiss
    Replies
    8
    Views
    1,126

    I agree Jay, but I don't bother removing shreader...

    I agree Jay, but I don't bother removing shreader cores on anything under 2 tons. As long as I have access to high & low sides. It's usually down to 150 microns when I get back from break.
  18. Replies
    26
    Views
    2,593

    Even if you had the right g.p.m. thru the coil,...

    Even if you had the right g.p.m. thru the coil, there's no way your going to get 15 tons of cooling with the supply & return backwards (no counter flow). I bet your air side t.d. is less than 10 deg....
  19. Replies
    21
    Views
    1,065

    My co. has a safety info. sheet with every...

    My co. has a safety info. sheet with every paycheck, and a safety meeting 6 times a year. I was bored at first. Now I think of my children whenever I want to save time and create a potential hazard....
  20. Replies
    20
    Views
    2,719

    The unit sometimes freezes? Start there.

    The unit sometimes freezes? Start there.
  21. Replies
    12
    Views
    658

    Then I would guess the tech. was not reading the...

    Then I would guess the tech. was not reading the suction line temp. accurately. Maybe using an infrared instead of a thermocouple. I'd say it's good to go.
  22. Replies
    24
    Views
    1,259

    Do you have a time delay thermostst?

    Do you have a time delay thermostst?
  23. Replies
    12
    Views
    658

    I'd like to know how you can have 22 deg....

    I'd like to know how you can have 22 deg. subcooling, 23 deg. t.d., and 27 deg. superheat. If you have low air flow, the superheat would be around 12 deg. If the airflow is o.k, then you're...
  24. Replies
    15
    Views
    1,350

    You will be o.k. if there's a t.x.valve. If cap...

    You will be o.k. if there's a t.x.valve. If cap tube, the 13 seer factory charge and extra subcooling will cause too low of a superheat. You'll have to recover some refrig. to get 14 deg. s.h. at...
  25. Thread: crane?

    by heykiss
    Replies
    26
    Views
    1,304

    Been there, the last few feet are the toughest,...

    Been there, the last few feet are the toughest, just when you're out of gas.Struggling to get it over the edge of the roof will make you wish you called the crane guy.