    I originally looked into the Arzel system and...

    I originally looked into the Arzel system and only found 1 local contractor that installed them. When I recently went to their website it looks like they dropped Arzel for Emme. The Emme sounded...
  3. Replies
    5
    Views
    1,131

    Opinions on Emme zoning system...

    Can anyone comment on how good or bad an Emme zoning system is? It sounds really cool and would work well with my modulating furnace and 2 stage ac unit. Is arzel better or worse?
  4. Replies
    1
    Views
    422

    Pump / hose kit to flush water heater?

    Can anyone recommend a pump / hose kit so I can flush my AO Smith Vertex 100 water heater? I do not have a floor drain in my basement. Thanks.

    Tom
  5. Leaving it where it is now, especially with an...

    Leaving it where it is now, especially with an addition planned, will not work because a new supply trunk would have to go up nearly 2 stories then about 30 feet across the attic - the airflow would...
  6. My current system is installed in my partial...

    My current system is installed in my partial basement. Unfortunately the remainder of the house is on a slab which is why my current situation limits the ability to run ductwork. If the equipment...
  7. I went through this energy program about 2 years...

    I went through this energy program about 2 years ago and had top notch equipment installed (Lennox G71V modulating furnace and XC21 2 stage ac along with an AO Smith Vertex 100 water heater). My...
  8. Thanks for the info. Has anyone tried the...

    Thanks for the info. Has anyone tried the Spacepak Aircell with ECM motor specifically?
  9. Anyone experience the Spacepak HV Aircell unit? Is it finally an efficient HV system?

    Still looking into HV systems but refuse to give up good efficiency. Now I see spacepak makes an Aircell model with an ECM motor. Any experiences or opinions? Is it efficient or still not?
  10. I was looking into buying a Winco tri fuel 5000...

    I was looking into buying a Winco tri fuel 5000 continuous watt portable generator run on natural gas. My other option us a 20kw Kohler whole house generator, but the cost is very high. Was hoping...
  11. What size portable generator for my Lennox G71V Furnace?

    I am going to purchase a portable generator for a few items in my home in the event of power failure. How much power will it take to run my Lennox G71V 110,000 Btu Gas Furance with ECM motor. I...
  12. By self contained... I mean a hydronic baseboard...

    By self contained... I mean a hydronic baseboard heater that does not require a separate boiler and plumbing run to each heater.

    I know standard electric baseboard heaters are not efficient and...
  13. Self-contained hydronic baseboard heat vs forced hot air

    What is the real cost difference to operate self contained hydronic baseboard heaters vs a 95% efficient gas furnace?

    Also what are the real performance differences?
  14. I looked into spray foaming the attic to make it...

    I looked into spray foaming the attic to make it conditioned space. The town inspectors and architect did not love the idea because 1) the cost around 10k and 2) if you ever re-roof or re-side all...
  15. The challenges I face... My house is a split...

    The challenges I face... My house is a split level and only has a partial basement. In addition many of the floor ceiling joists change direction making duct runs near impossible (unless i move the...
  16. Is there any way to have an efficient high velocity system?

    Is there a spacepak or unico system that can provide high energy efficiency? Everything i read seems to say that i will only get about 11 seer with high velocity which sucks. I see spacepak now...
  17. Replies
    46
    Views
    4,971

    Attic ventilation

    My neighbor is having a 2 zone hvac system installed with 1 zone having the equipment and ductwork in the attic. I have been wanting to move my system to the attic but haven't because of all the...
  18. Picking a foam installer will be the tricky part....

    Picking a foam installer will be the tricky part. Some contractors work is so wavy. You see 2 inches in one spot and 6 in another.

    As for ductwork I refuse to have flex installed. I will insist...
  19. I have a Lennox G71V modulating furnace and an...

    I have a Lennox G71V modulating furnace and an XC21 2 stage ac unit. I think this furnace should be able to work and being that it is modulating it will run in 10% increments from 40%. So even if...
  20. Has anyone spray foamed an attic with an hvac system?

    I live in NJ and am considering closed cell spray foam for my attic. Closed cell foam would be installed on the underside of the roof and on the attic walls. The soffits would also be sealed. I...
  21. Replies
    10
    Views
    2,205

    Just to clarify my original post. I was looking...

    Just to clarify my original post. I was looking at some ductless mini split systems that come with seven zones. The smallest zone of the seven would be 6,000. I thought that 6,000 would be too big...
  22. Replies
    10
    Views
    2,205

    Ductless mini split question

    Other members suggested that I look into ductless mini splits since my idea of having a conventional ducted system installed in the attic is a bad idea.

    So if I have 7 total rooms - 4 bedrooms, 2...
  23. I see your point now. So while it is not as good...

    I see your point now. So while it is not as good as the dropped ceiling soffit, it would still have to be better than just regular r8 ductwork in the attic?

    The attic ductwork layout would serve...
  24. I feel like mini split is just not the same as a...

    I feel like mini split is just not the same as a conventional system. Maybe I need to do more research.

    So if it is not considered as part of conditioned space, it would still have to be better...
  25. Soffit / bulkhead on attic side for ductwork...

    Considering a house addition and want to have the 2nd floor be its own zone with separate furnace and ac. I have room to have the furnace installed in a second floor closet and want to have the...
  26. Replies
    15
    Views
    8,313

    There is plumbing in the basement, but it is...

    There is plumbing in the basement, but it is quite a distance from the furnace and condensate pump. My brother just bought the house and the furnaces are very old, despite being high efficiency. We...
  27. Replies
    15
    Views
    8,313

    Condensation line keeps freezing

    My brother just bought a home where the condensation hose for the furnace goes to the outside of the house via a clear hose. After we found a puddle of water by the furnace and could hear the...
  28. That makes me so happy to hear. Thanks!

    That makes me so happy to hear. Thanks!
  29. Can a Lennox G71 upflow be converted to horizontal?

    Considering a smallish house addition and need to know if my current upflow Lennox G71 furnace could ever be utilized as a horizontal unit and moved to the attic??? It would allow for a much better...
  30. I guess I just have to decide if I am willing to...

    I guess I just have to decide if I am willing to rip open ceilings and soffits to try to get the situation corrected. I would love to be able to rent the tool that measures cfm from each register. ...
  31. Well I am glad to hear that the small initial...

    Well I am glad to hear that the small initial take off from the plenum shouldn't affect the supply trunk as it enlarges.

    This leaves me with one last question.

    If a supply branch starts off...
  32. I always question the airflow from this...

    I always question the airflow from this particular trunk which is why I ask. Presently, this trunk feeds (2) 4" ducts, (4) 5" ducts, and (5) 6" ducts. Generally, 4" ducts should supply 30cfm, 5"...
  33. Ductwork question - starts small then gets bigger

    I understand that generally ductwork sizes get reduced as they get longer to maintain airflow. But in my home I have either a 10x10 or 10x12 supply trunk off the plenum and then enlarges into a...
  34. We went through a program that involved a state...

    We went through a program that involved a state energy audit and professional air sealing. The house leakage was cut in half. The 2 rooms do heat better when the doors are left open, but it is not...
  35. Well I tried my best to get the contractor to...

    Well I tried my best to get the contractor to enlarge the ductwork appropriately. The biggest issue was the 10x14 trunk which is limited in size because it has to fit between the ceiling joists -...
  36. My home is a split level about 2200 square feet. ...

    My home is a split level about 2200 square feet. I have a partial basement and a crawlspace off of it. I had a blower door test done which showed air leakage of around 2200 - I was originally at...
  37. The whole thing doesn't make much sense. As for...

    The whole thing doesn't make much sense. As for the system I cannot separate the ductwork between floors because it is a split level house. Zoning is an option, but it comes with a hefty price -...
  38. Well, the only other consideration is that the...

    Well, the only other consideration is that the redesigned ductwork still has too much static pressure.

    I did however, just read an article that stated that the ecm motors only provide that high...
  39. I called Lennox and spoke to a technical rep, who...

    I called Lennox and spoke to a technical rep, who asked me first about my utility bills. Since August of last year, my gas bills have been cut in half but my electric usage has doubled. The tech...
  40. Anything we overlooked to improve heating with Lennox G71?

    Once last post on this... I have a Lennox G71 110,000 btu furnace, XC21 4 ton ac unit, and Honeywell Visionpro IAQ thermostat. House was originally built with just heat so duct work was always...
  41. Hot Water Recirculators to Solve Freezing Pipes?

    I have 2 sets of copper water pipes that have frozen 2 or 3 times over the last 5 years in my house. Fortunately they haven't ever burst. 1 set was in a half bathroom that is on a concrete slab. I...
  42. Replies
    7
    Views
    788

    The situation has improved... Verified that my...

    The situation has improved...

    Verified that my HW VisionPro IAQ was set to 2 stage heat and that my Lennox G71 was set to modulating. I was able to increase my low speed heat by 15% and decrease...
  43. Replies
    7
    Views
    788

    My mistake... 1 indoor sensor. The contractor...

    My mistake... 1 indoor sensor. The contractor installed 2 but we had to disconnect 1 so it would work.
  44. Replies
    7
    Views
    788

    The contractor unfortunately skipped out on a lot...

    The contractor unfortunately skipped out on a lot of people leaving us high and dry. Fortunately I was confident that the actual install guys did a fairly good job.

    I went with a HW VisionPro IAQ...
  45. Replies
    7
    Views
    788

    Lennox G71 question...

    Contractor installed a new Lennox G71 furnace, XC21 AC unit, and corrected some of the undersized ductwork that was original to the home. The AC ability was dramatically improved, however we...
  46. Replies
    8
    Views
    1,139

    I just disabled the outdoor sensor which disables...

    I just disabled the outdoor sensor which disables the frost protection. I set the humidity level to 45% and the furnace blower is set to turn on and run the humidifier even if the temp is met.
    ...
  47. Replies
    8
    Views
    1,139

    We had a lot of air sealing installed. Our...

    We had a lot of air sealing installed. Our original energy audit showed a 4300 rating of leakage and now we are down to 2200. The humidifier had no problem maintaining 45-50% RH when the temps were...
  48. Replies
    8
    Views
    1,139

    Humidity level not reaching set point?

    I have a Lennox G71 furnace, Aprilaire 400 humidifier, and Honeywell VisionPro IAQ thermostat. I have 2 remote indoor sensors and 1 outdoor sensor. We set the humidity level on the thermostat to...
  49. Replies
    24
    Views
    3,313

    So here is the outcome... 2 sensors were...

    So here is the outcome... 2 sensors were installed, however only 1 is hooked up and now everything works fine. The contractor called Honeywell's contractor customer service and they said only 1,4,9...
  50. Replies
    24
    Views
    3,313

    The company sends a different guy out everytime...

    The company sends a different guy out everytime and they all tell me they have never installed this thermostat or sensors...

    Fortunately, I called Honeywell and told them that I was not happy with...
Results 1 to 50 of 154
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event