    lennox hp21 heat pump

    Thanks everybody. I guess I know what I get to do this week regarding the indoor txv. I was a little thrown by refrigerant being able to flow through the equalizer on the outside txv, turn the whole...
  2. Replies
    10
    Views
    2,689

    lennox hp21 heat pump

    The freezing was at the txv equalizer tube in the outdoor unit, it goes down to the suction line a few inches from the compressor inlet.
  3. Replies
    10
    Views
    2,689

    lennox hp21 heat pump

    The subcooling was around 18-20 degrees when it was working right, but that didn't happen for long.

    As the pressure progressively dropped to 0, the suction line would actually get warmer (from...
  4. Replies
    10
    Views
    2,689

    Worked on a Lennox two speed heat pump HP21....

    Worked on a Lennox two speed heat pump HP21. customer complained that it would run for an hour or two and then quit cooling. Gave a general once over, running at 70psi low side, under 200 high side,...