  1. Replies
    2
    Views
    1,145

    I really do need to find a wiring diagram on this...

    I really do need to find a wiring diagram on this unit. Customer just bought an old building and it has one of these on the roof. Condenser fan is cycling on for just a few seconds then off for...
  2. Replies
    4
    Views
    2,400

    Does anyone know of a source for evaporator coils...

    Does anyone know of a source for evaporator coils that fit in a Lennox CB18 Series Air Handler (installed in 5/1985). This system uses an inverted A coil design and has a TXV metering system. The...
  3. Replies
    26
    Views
    3,713

    Thanks for the input.

    Thanks for the input.
  4. Replies
    60
    Views
    6,184

    You can't take short cuts

    Like everyone else is telling you, the System should be properly evacuated to eliminate any and all condensables in the system. I would have added or replaced the liquid line driers on both systems...
  5. Replies
    26
    Views
    3,713

    I would appreciate some input on the best choice...

    I would appreciate some input on the best choice (most useful) type of Halon gas leak detector. Pump style, bernomatic flame, heated pentode type, or ultrasonic detector? Also, any experience on...
  6. Replies
    0
    Views
    1,717

    Can anyone suggest a source for a wiring diagram...

    Can anyone suggest a source for a wiring diagram for a Bryant model Number 655ANX042000AAAG. The diagram posted on the inside of the fan box has evidently had mold growing on it long enough to...
  7. Replies
    5
    Views
    1,337

    Yes we do need that much cooling

    Thanks for the help guys. Yes, this is a VERY large house located in South Georgia (about 50 miles North of the Fla line). There is also another 3.5 ton package unit cooling another part of this...
  8. Replies
    5
    Views
    1,337

    Hey Guys, I need to replace an old Lennox gas...

    Hey Guys,

    I need to replace an old Lennox gas furnace (LP gas fired). This is a split system and has a 7.5 ton condensing unit outside. The compressor is the only device at this residence that...
  9. Replies
    10
    Views
    1,179

    Thanks Guys

    Thanks for all the input. If I was doing this for someone else other than myself, I would, without hesitation just replace the whole unit. I was basically given this old unit and am planning on...
  10. Replies
    10
    Views
    1,179

    I am not sure what killed the last compressor, I...

    I am not sure what killed the last compressor, I do know that for the last two years that compressor was sounding funny as it was running. I would guess maybe bad bearings, but it did progress to a...
  11. Make sure you gas valves are all the way open....

    Make sure you gas valves are all the way open. Make sure there is no restriction in the gas line to the unit. You should really test the gas pressures with a manometer to make sure you have the...
  12. Replies
    10
    Views
    1,179

    I have a bryant Model 655ANX042000AAAG Serial...

    I have a bryant Model 655ANX042000AAAG
    Serial 1396G10284.

    Overall the unit is in great shape no leaks, but has just experienced a compressor burn out. Currently installed is a Copeland 42K recip...