  1. Replies
    13
    Views
    1,138

    What is the measure that you take test the unit...

    What is the measure that you take test the unit again to get it to come back on? As in, once you test the unit and it shuts down after two minutes, what do you do to test the unit again? Remove 240v...
  2. Replies
    9
    Views
    1,776

    I've came across a few bad HX in Armstrong...

    I've came across a few bad HX in Armstrong units... by volume I would say 50% are cracked... i can think of one of which looked just like a major manufacturing error. Junk IMO.
  3. Replies
    33
    Views
    4,855

    Ugh... haunting memories of installing and then...

    Ugh... haunting memories of installing and then removing suction driers in TRANE resi units. Especially the newer ~16 SEER R410a units. Who can do a handstand while brazing? Good times.
  4. Replies
    38
    Views
    4,244

    Yup assuming has left me scratching my head a...

    Yup assuming has left me scratching my head a time or two... and it always sucks explaining something like that to a homeowner, when your guy was there to assure operation and safety... and now they...
  5. Replies
    38
    Views
    4,244

    Funny how things end up working out.... but...

    Funny how things end up working out.... but didn't you bypass/jump the limits first? Way to figure it out though.

    So what about your guy that performed the PM????? He didn't see the dime sized...
  6. Replies
    38
    Views
    4,244

    I'm still saying bad valve... Or maybe a...

    I'm still saying bad valve...

    Or maybe a grounding issue.

    Also just remembered - disconnect the power supply and check for voltage between neutral and ground. Shouldnt have more than 0.5vac if...
  7. Replies
    38
    Views
    4,244

    What piece of equipment are you working on? ...

    What piece of equipment are you working on?

    Did you try to jumper the pressure switch? Do you continue to have 24v signal to the valve?

    I had similar occurrence with an older Rheem 80%. Valve...
  8. Damn... I'm surprised at the companies here that...

    Damn... I'm surprised at the companies here that "don't run warranty calls after hours."

    That is insane.

    There are indeed many things that can wait until regular business hours. But, usually if...
  9. Sorry for delay in update. So I went back out...

    Sorry for delay in update.

    So I went back out to troubleshoot the furnace again after speaking with the Bryant TSA. When I explained everything to him, he first was convinced something was in the...
  10. Replies
    557
    Views
    94,479

    Anytime I hear the engineer bit I usually respond...

    Anytime I hear the engineer bit I usually respond with something borderline smartass. Of course it depends on their attitude and what they say... and I used to bite my tongue. But. One can only take...
  11. Replies
    557
    Views
    94,479

    You can disable the Adaptive Intelligence...

    You can disable the Adaptive Intelligence Recovery feature on Honeywell programmable thermostats.

    Just sayin'.
  12. The Lennox 90%+ I mentioned above had a similar...

    The Lennox 90%+ I mentioned above had a similar problem, except it would NOT ignite via the HSI. Could only get it to light manually with open flame. Swirling combustion air...

    Except this Bryant...
  13. This style of unit, as well as the Carrier...

    This style of unit, as well as the Carrier counterpart all have that single burner assembly I believe? The burner assembly slides into the burner compartment, one end of the manifold slides into a...
  14. Yes I believe it does. Interesting to note... ...

    Yes I believe it does. Interesting to note...

    Also to mention, this house was a foreclosure and this is the first winter with the h/o living there. For all we know this was a previous ongoing...
  15. Thanks for all the replies fellas. And like I...

    Thanks for all the replies fellas.

    And like I said... after the first series of the unit not firing properly I dismantled the manifold, removed and blew through the orifices and manifold multiple...
  16. When I first got there, before I knew what was...

    When I first got there, before I knew what was causing the lockout, and cycled the unit numerous times with normal operation the burners were igniting smoothly and normally. But after witnessing the...
  17. Sounds like some of guys ought to be packing...

    Sounds like some of guys ought to be packing around a bucket of Crisco.

    Haha ;)

    No but really, I'm young and in pretty good shape, 5'11" and 180.... and I've felt that bit of panic before when...
  18. The unit is horizontal in an attic. But damn...

    The unit is horizontal in an attic. But damn thats interesting... like it gives the burners a strange coating or something? I did give them a good wire brushing just for good measure even though...
  19. Done. Could easily fit a dime between them....

    Done. Could easily fit a dime between them....
  20. Bryant 80% furnace, only one burner firing intermittently.

    Working on a Bryant 80%, model #: 310AAV03607AAJA manufactured in '02.

    Had a client call in, saying every other day or so the unit locks out and must reset power to control. Unit is running when I...
  21. So you went ahead and installed the system...

    So you went ahead and installed the system regardless... Well that's where you made a mistake. When he was telling you "I'm paying you to install it blah blah blah" you shouldve said you're doing the...
  22. Replies
    6
    Views
    776

    Repairing aluminum coil?

    Have a R410a Trane HP that has developed a moderately slow leak due to the OD TXV rubbing up against one of the aluminum tubes of the spine-fin OD coil. I've seen a few aluminum coil failures over...
  23. Replies
    15
    Views
    3,231

    I wonder if they properly recovered the...

    I wonder if they properly recovered the refrigerant to be in compliance with The Clean Air Act...
  24. Replies
    11
    Views
    2,118

    Coil was flipped yesterday... Now its going into...

    Coil was flipped yesterday... Now its going into high head in heat mode. Headed back out tomorrow to troubleshoot. Client believes it has never ran properly in heat mode. What a mess. A god awful...
  25. Replies
    11
    Views
    2,118

    Can you spot the problem?

    Yup those damn 2 piecer's make things confusing!!!!

    And the real shame here is that our company is responsible for this... One of our guys installed the ah/coil about a year and a half ago, with...