Search:

Type: Posts; User: qtip

Page 1 of 13 1 2 3 4

Search: Search took 0.10 seconds.

  1. Replies
    10
    Views
    260

    $0.10....got a few in the garage if you want...

    $0.10....got a few in the garage if you want them, willing to negotiate.
  2. Replies
    9
    Views
    350

    Previous tenant take the PC with Summit on it?

    Previous tenant take the PC with Summit on it?
  3. Discharge air? Maybe?

    Discharge air? Maybe?
  4. No Flipping way! Why take a pay cut and lose...

    No Flipping way! Why take a pay cut and lose benefits.
  5. Replies
    66
    Views
    2,016

    WOW I didn't know a VAV air system is like rocket...

    WOW I didn't know a VAV air system is like rocket science. Boiler on if heating is needed, boiler off if no heat is needed. Use what ever variable you need to decide to heat but the bottom line is...
  6. Thread: Trane WCIs

    by qtip
    Replies
    8
    Views
    693

    Don't forget to "Open Network" with TU.

    Don't forget to "Open Network" with TU.
  7. Replies
    8
    Views
    677

    Location? There is always the Tridium route.

    Location?
    There is always the Tridium route.
  8. Replies
    8
    Views
    677

    BTMB converts the legacy communication protocols...

    BTMB converts the legacy communication protocols to Bacnet/IP. SC is the replacement for BCU and is web based.
  9. Replies
    8
    Views
    677

    Need BTMB and SC per 120 devices.

    Need BTMB and SC per 120 devices.
  10. Same ole song and dance! 1) Need to replace...

    Same ole song and dance!

    1) Need to replace the UCM boards on the two VAV boxes that are not communicating.Yup
    2) No need for the SC software, he can either upgrade the version 11 software to...
  11. Man I haven't seen a set of those gauges in 15+...

    Man I haven't seen a set of those gauges in 15+ years. Brings back memories though not all good.
  12. Wait a minute I never said I was sharp on...

    Wait a minute I never said I was sharp on either!:cheers:
    Just been in the trade a loooonnnnggg time.
  13. 12 psig range / 200 deg range = .06 psig per...

    12 psig range / 200 deg range = .06 psig per degree of change

    .06 X 100deg = 6 + 3 pig starting point = 9 psig which is the middle of the temperature range.
  14. Replies
    8
    Views
    621

    Manual in truck but its too damn cold to go get...

    Manual in truck but its too damn cold to go get it. From memory its terminal 3-4 for external interlock. look at wiring diagram
  15. Replies
    12
    Views
    1,466

    Hmmmm old copy paste from an old engineering spec?

    Hmmmm old copy paste from an old engineering spec?
  16. Replies
    3
    Views
    439

    Bacnet/MSTP over IP to the device level, SC is a...

    Bacnet/MSTP over IP to the device level, SC is a router. You will not get VAS, Chiller Plant Control or Area Control information with out fat fingering it into SC. Not the same as a BCU.
  17. Replies
    44
    Views
    4,372

    programfiles\tracersummit\pdfs

    programfiles\tracersummit\pdfs
  18. Replies
    44
    Views
    4,372

    Sounds like you are moving in the right direction.

    Sounds like you are moving in the right direction.
  19. Replies
    44
    Views
    4,372

    So what is the status of this project?

    So what is the status of this project?
  20. Replies
    44
    Views
    4,372

    No you need to get Tracer Summit operational. I...

    No you need to get Tracer Summit operational. I doubt that you need rover as most of your devices are application specific. With the right phone calls by the right person your software can be...
  21. Replies
    44
    Views
    4,372

    Have you had Trane out at all? Really sounds...

    Have you had Trane out at all?
    Really sounds like a days labor to provide options. Might be worth the investment it you are really talking about swapping out all the controls because you cannot see...
  22. Replies
    44
    Views
    4,372

    :Faint: You need Summit

    :Faint: You need Summit
  23. Replies
    44
    Views
    4,372

    VAVs are Traic short to ground, one terminal is...

    VAVs are Traic short to ground, one terminal is 24v supply and the other two short to ground to operate the actuator, you will notice 24v on all three wires. You can remove one of the drive open or...
  24. Replies
    32
    Views
    5,597

    Does have a sweet power recepticale to plug your...

    Does have a sweet power recepticale to plug your laptop into though.
  25. Replies
    6
    Views
    782

    Particulate monitor is very vauge. What is the...

    Particulate monitor is very vauge. What is the particulate?
    Clean rooms I have done in the past required this to be done by a lab to find the exact type of particulate or contaminate to the process.
  26. Replies
    5
    Views
    730

    I have been dabbling for 18 years or so and can't...

    I have been dabbling for 18 years or so and can't complain. I will agree about bieng behind but Trane is cathing up fast. Not being Java based is a big advantage.

    If the price is right jump all...
  27. Thread: Trane BCU Access

    by qtip
    Replies
    3
    Views
    518

    Need Summit

    Need Summit
  28. Replies
    5
    Views
    578

    Gotta love AX...every time a Java update comes...

    Gotta love AX...every time a Java update comes out it won't work.
  29. Replies
    6
    Views
    848

    SCC or DAC?

    SCC or DAC?
  30. Replies
    1
    Views
    620

    Think about the file structure....you'll get it.

    Think about the file structure....you'll get it.
  31. Replies
    29
    Views
    2,345

    Punk! :eek2:

    Punk! :eek2:
  32. Replies
    29
    Views
    2,345

    Did that years ago....Way too old for that, the...

    Did that years ago....Way too old for that, the back cannot handle it.
  33. Replies
    29
    Views
    2,345

    I use this http://www.instand.com/CR3/cr3.shtml...

    I use this http://www.instand.com/CR3/cr3.shtml
    weigths 26oz and fits in my laptop bag.
  34. Replies
    11
    Views
    1,028

    The Nest cost more than the window shaker!

    The Nest cost more than the window shaker!
  35. Replies
    8
    Views
    767

    You have not result or argument for L2. Just...

    You have not result or argument for L2.
    Just turn 14 on and OAD Calc goes to 0 if no SFanStat or not Occupied
  36. Replies
    8
    Views
    767

    Turn line 14 ON

    Turn line 14 ON
  37. Replies
    11
    Views
    663

    I had a TAB company like that at one time also,...

    I had a TAB company like that at one time also, you must break them of that habit. When bidding a job you have no idea which TAB is going to show up so you can not cover your hours with the $$$$ in...
  38. Replies
    11
    Views
    663

    That should really be the balancer problem not...

    That should really be the balancer problem not yours, that is what they get paid for.
  39. Replies
    11
    Views
    663

    Ask your local Trane office for a copy of TU. If...

    Ask your local Trane office for a copy of TU. If it is not licensed just AWB works. Sorry I am not in your area I have it on my jump drive for balancers.
  40. Replies
    11
    Views
    663

    TU is free for balancing.

    TU is free for balancing.
  41. Replies
    32
    Views
    2,267

    Turn the temperature UP! 72 is freaking cold in...

    Turn the temperature UP! 72 is freaking cold in my opinion.
    Could be senile though :cheers: or move north where we still use heat and have snow on the ground.
  42. I think I am going to steal your "Beer Tokens"...

    I think I am going to steal your "Beer Tokens" verbiage! :cheers:
  43. Replies
    4
    Views
    482

    You can pay me if you want! PO number please...

    You can pay me if you want! PO number please :whistle:
  44. Replies
    4
    Views
    482

    SC acts as a Bacnet/IP router. Anything in the...

    SC acts as a Bacnet/IP router. Anything in the unit controller will be available via Bacnet/IP but you must remember anything the SC is controlling will take priority. If you are just polling data no...
  45. Just the school of hard knocks

    Just the school of hard knocks
  46. Replies
    26
    Views
    2,190

    Hey you ever been in Da U.P.? It's still like...

    Hey you ever been in Da U.P.? It's still like that!
  47. Replies
    17
    Views
    1,325

    I know what that FM means! :cheers:

    I know what that FM means! :cheers:
  48. Replies
    9
    Views
    954

    none

    none
  49. Replies
    4
    Views
    656

    Looks like S4 it is. :whistle:

    Looks like S4 it is. :whistle:
  50. Replies
    14
    Views
    1,970

    IFeelYourPainBeenDoingThatForYearsAndItShowsUpInMo...

    IFeelYourPainBeenDoingThatForYearsAndItShowsUpInMostOfMyEmailsAlso
Results 1 to 50 of 616
Page 1 of 13 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards