Search:

Type: Posts; User: jappell

Page 1 of 5 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    10
    Views
    751

    they are shat indeed let us know

    they are shat indeed
    let us know
  2. Replies
    10
    Views
    751

    Mani water inlets are now yellow and impossible...

    Mani water inlets are now yellow and impossible to just do the four screw change. Theres after market valves that line right up for the four screw method! We use the genuine service parts number 56675
  3. Replies
    3
    Views
    350

    Your probably seeing a CPR, crankcase pressure...

    Your probably seeing a CPR, crankcase pressure regulator. Is it right before the freezer compressor? Used to keep liquid refrigerant from washing the oil out of the pump, You set them by amps on...
  4. Replies
    12
    Views
    1,366

    We have a bar that had an S model Mani that would...

    We have a bar that had an S model Mani that would get very nasty and the regular maintainence was always a nasty chore, and the owner was always there to see (and get disgusted) She got a new indigo...
  5. Replies
    24
    Views
    2,329

    yeah and sell them to my customers......... the...

    yeah and sell them to my customers......... the ones with the beat up True tssu that needs a compressor and cap tube.
    We try to talk them out of it and go new, 3 year warranty. They take our advice...
  6. Replies
    22
    Views
    2,205

    there can't be a fan cycle and headmaster, or am...

    there can't be a fan cycle and headmaster, or am I missing somthing
  7. Replies
    135
    Views
    7,525

    On 115 volt power cord the smooth side is hot,...

    On 115 volt power cord the smooth side is hot, ribbed is neutral.
  8. Replies
    135
    Views
    7,525

    cr14, we all still want to encourage you, but...

    cr14, we all still want to encourage you, but 2sac has some valid points, and what about calling traulsen?
    10 pages of going around in the same circle is not the way to get a service call done. best...
  9. :cheers: I think so, the ones I saw also closed...

    :cheers:
    I think so, the ones I saw also closed the LLSV
  10. I've seen it ...........twice maybe in the...

    I've seen it ...........twice maybe in the hundreds of coolers I've seen, always thought it was pretty cool!
  11. You should have never left.........it was down?

    You should have never left.........it was down?
  12. Replies
    7
    Views
    935

    So united finally got Us the pump yesterday, nice...

    So united finally got Us the pump yesterday, nice install. Started up fine, at this point only an eight of a tank left.
    Tank got filled today and it was cycled off at 300 psi. It is controlled by...
  13. Replies
    7
    Views
    935

    Waiting still, 460 volt will be in tomorrow. it...

    Waiting still, 460 volt will be in tomorrow.
    it does seem to run off tank pressure, 2 cap tubes running to control box from tank. Their hooked up to a stat that de-energizes the LLSV. Will let You...
  14. Replies
    7
    Views
    935

    Thanks, right now that tank is sitting in the...

    Thanks, right now that tank is sitting in the florida sun just oozing co2 thru the pressure relieves. So they need to be <50F to stop dumping.........good to know!
  15. Replies
    7
    Views
    935

    CO2 storage tank refrigeration

    I have never worked on one and got a call only to find the compressor has open windings.
    Tommorrow the new one goes in and I'd like
    to know what I'm not seeing inside the 6 ton tank.ie the eval...
  16. Thread: traulsen

    by jappell
    Replies
    4
    Views
    734

    Low charge, find and fix the leak, replace drier...

    Low charge, find and fix the leak, replace drier and evacuate, charge to name plate and Your done.
  17. Replies
    40
    Views
    4,945

    Yeah, for a -10 freezer, different story.

    Yeah, for a -10 freezer, different story.
  18. Replies
    40
    Views
    4,945

    They ARE different.........

    They ARE different.........
  19. Replies
    40
    Views
    4,945

    Jon Baily has an accent! Good stuff!

    Jon Baily has an accent!
    Good stuff!
  20. Replies
    21
    Views
    1,739

    :grin2:

    :grin2:
  21. Replies
    5
    Views
    628

    our gov at work

    http://www.bloomberg.com/news/2013-09-04/safeway-agrees-to-stop-leaks-of-refrigerant-chemical.html?cmpid=yhoo

    good or bad?
  22. any new install or un opened system i always use...

    any new install or un opened system i always use a n2 purge, on old junk sometimes not. Always a micron gauge, it's the only way to tell if it holds, a side note, why do my microns lower after...
  23. Replies
    10
    Views
    1,706

    if your low on charge the head master will be...

    if your low on charge the head master will be dumping hot gas into the liquid line.......is it real hot to the touch? add a bit of refrigerant and see if it cools down. If so, as previously...
  24. Replies
    21
    Views
    3,934

    Thanks for resrurrecting, '05 was a good year,...

    Thanks for resrurrecting, '05 was a good year, learned alot after we installed a used 5 door freezer with a new copeland sled. 3 days later customer calls about frost on product boxes.........3 to...
  25. Our shop just changes the cap tube, too many...

    Our shop just changes the cap tube, too many heart breaks of starting a new pump just to find it plugged, when We replace a failed compressor. Happy Mothers day!
  26. Replies
    11
    Views
    1,388

    Experience, and this site really helps guide You...

    Experience, and this site really helps guide You in the right direction, keep up the learning!



    sent from my dumb ass verizon upgrade.
  27. Replies
    32
    Views
    3,363

    Hoshi seems to have proved itself Why mess with...

    Hoshi seems to have proved itself
    Why mess with success
  28. Replies
    14
    Views
    1,601

    Two last week alone. ........ Manitowack!

    Two last week alone. ........ Manitowack!
  29. Replies
    20
    Views
    2,427

    Hey jpena, lighten up and laugh, the smell is no...

    Hey jpena, lighten up and laugh, the smell is no big deal.I'm with ice miester, them old days of one oil is one sweet memory.
  30. Replies
    6
    Views
    1,397

    Ditto on bad valves in comp.

    Ditto on bad valves in comp.
  31. Replies
    14
    Views
    1,923

    icemeister.....

    I'm gonna stop by and buy You lunch someday................You are awesome!
    Arcadia is about as far east as I work but a day trip is overdue, I'm buying!
  32. Thread: walkin cooler

    by jappell
    Replies
    18
    Views
    1,898

    Maybe......

    A broke bobtail above the harness over the pot in the service chamber?
  33. Replies
    12
    Views
    4,596

    They have a new twist................M2...

    They have a new twist................M2 controller, the one I saw had no info on the panel door, as far as codes, etc.......I got a small book but have no way of posting. I was thinking that number...
  34. Replies
    12
    Views
    4,596

    I just today installed the smoke detectors on...

    I just today installed the smoke detectors on that M2. I've always liked Lennox, this seems good. Started up 3 weeks ago, purring like a kitten!
    I call 1-800-367-6285, Good luck.
  35. Replies
    13
    Views
    1,274

    It's just his little/big collectable, waiting for...

    It's just his little/big collectable, waiting for him to get back to me. We always use the 032capt driers, just need to use a better refrigerant!
  36. Replies
    13
    Views
    1,274

    I think the 134 is the probelem, shoot. 404 cap...

    I think the 134 is the probelem, shoot. 404 cap tubes don't seem to plug as bad, nor 22 systems with newer poe compressors. It's a steel condenser with fins big enough to drive a harley...
  37. Replies
    13
    Views
    1,274

    Multiple cap tube failures

    Old R 12 vending machine, 2006 new pump with POE oil and 134, now the second cap tube is plugged. I say lets just put a reciever and TXV..... boss reminds me customer already paid for cap...
  38. Replies
    4
    Views
    635

    Whats wrong.....

    with the download?
  39. Replies
    14
    Views
    1,437

    We just hope

    The ice was cleared before You added charge! BTW.....did You check the TXV screen?
  40. Replies
    7
    Views
    2,691

    Your welcome

    $170.00 us Please :rules:
  41. Replies
    7
    Views
    2,691

    definatly

    Call a refrigeration company, any and all restaurants needs a good one!
  42. Thread: High side leak

    by jappell
    Replies
    13
    Views
    1,771

    [QUOTE=COBO19;4134622]Jettmac I would...

    [QUOTE=COBO19;4134622]Jettmac

    I would normally evacuate the system when I repair a leak,either high side or low, like I said in my first post I know that is the proper and protocol way of...
  43. Thread: hoshi

    by jappell
    Replies
    8
    Views
    1,042

    I had one that took three trips to find the water...

    I had one that took three trips to find the water pump was the culpret. It would run, then NOT!!
  44. Thread: Respect

    by jappell
    Replies
    14
    Views
    1,456

    OH shoot me with a grilled...

    OH shoot me with a grilled cuban................plenty of salt in the meat, as long as the veggies are cold! Seriously, though, it is the iceing on the cake when we truly are apreciated.
  45. Replies
    6
    Views
    3,944

    No way

    You trouble shot an ice machine in the clean mode. Then ordered a board? Ok, so can we have an update?
  46. Replies
    5
    Views
    880

    Me too. It just made sense, 'cause that is a...

    Me too. It just made sense, 'cause that is a mighty high suction, 32psi is over 0 degree.
  47. Replies
    5
    Views
    880

    Yeah but I seen one pump down to 8 or so befor...

    Yeah but I seen one pump down to 8 or so befor the evap fans came on. Then level out at 13 or so. This one would not take the 15 oz due to that LLSV, so.... thats how I know the charge is short, I...
  48. Replies
    5
    Views
    880

    Wrong cap-tube?

    True, brand new TUC-48F 4 drawer freezer. Won't drop below 17. Added low side suction tap......32 psi back presure. Called True and Ron agreed bad pump. Installed new pump, nitro purge, new drier,...
  49. Replies
    8
    Views
    1,089

    The first one I did threw me off because the evap...

    The first one I did threw me off because the evap has a lip in the back so you have to push it up then pull it out. The screws are on the side behind those foam plugs. No worries with the silicon....
  50. Replies
    3
    Views
    896

    Stop Resettimg

    and call a liscend contracter!!!
Results 1 to 50 of 205