Search:

Type: Posts; User: castillo7411

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    551

    wow a bit far, but the areas that we deal with is...

    wow a bit far, but the areas that we deal with is some cook, lake and mchenry countys
  2. Replies
    2
    Views
    551

    Illinois technician job posting

    Any one know of a good site to post openings?
  3. Replies
    18
    Views
    2,221

    Last time I saw a truck like that I was in the...

    Last time I saw a truck like that I was in the junkyard emptying out one of our vans that had flipped in a snow storm.
  4. Replies
    12
    Views
    2,328

    I wonder how much it weighs? That would be real...

    I wonder how much it weighs? That would be real good for commercial applcations, somehow drive the vehicle up the wall, park it on the roof next to the unit, pull a Mcgyver, strip the car/van for...
  5. Thread: N

    by castillo7411
    Replies
    13
    Views
    1,929

    We have been installing those coils now for...

    We have been installing those coils now for awhile without any installation errors. HOWEVER about a month and a half ago we put in a condensor and coil, installer said it was all good. Customer...
  6. Oh but it does "replace every three months" I...

    Oh but it does "replace every three months"
    I love it when the customers complain, but the filter says every three months, what do you mean my problem is just a dirty filter. So I just tell them to...
  7. Replies
    16
    Views
    5,892

    referrob, Exactly, the furnace I was servicing...

    referrob, Exactly, the furnace I was servicing was doing something very similar, when the blower would run on low stage, the motor was reving up for less than a second it was noticed by the homeowner...
  8. Replies
    5
    Views
    544

    My boss, the owner of the company, had me install...

    My boss, the owner of the company, had me install one for him in his house, Its run thru the Carriers infinity system, but he says it has been the best he has ever used.
  9. Replies
    16
    Views
    5,892

    When you say the fan speeds up then down again...

    When you say the fan speeds up then down again are you refering to the blower motor or the inducer motor?
  10. Replies
    15
    Views
    2,311

    Some of the more common cracks in the Janitrol...

    Some of the more common cracks in the Janitrol units are in the ones that have the double shafted motor, I don't know model number but they are 150k btu and are about 10 years old. Seems to me like...
  11. From what I can tell this is a Base model Carrier...

    From what I can tell this is a Base model Carrier a/c and because of that I can only imagine that the furnace is the same. I can't say this is the worst install, however I have been going out on...
  12. Replies
    20
    Views
    1,413

    68 in dead of summer

    There are two customers who keep their t-stat set to 68 in the summer cause they like it cold whn we did the install we went to a five ton from a four ton added more return and supplies i cant...
  13. Replies
    3
    Views
    644

    Fan Schedule

    I think that there is a fan program that may be active where if it was programmed it would come on or the fan may just be set for continues high speed look on the upper right and see what it says.
  14. Replies
    9
    Views
    1,020

    Sorry, I think the 4" with the 1" fiber type is a...

    Sorry, I think the 4" with the 1" fiber type is a very good Idea, and I was simply pointing out what NOT to do to get the 5" or 4" width.:o Sorry about the confusion!
  15. Replies
    9
    Views
    1,020

    That is very good thinking McGyver, I had a...

    That is very good thinking McGyver, I had a customer once who called for a no heat and guess what i found.......he just replaced his filter(s), High limit stuck, he had a 16x25x4 cabinet but said he...
  16. Replies
    5
    Views
    4,040

    Depending on the original length of the lineset...

    Depending on the original length of the lineset some or all may be able to be pushed back into the condensor. And yes as stated if it is being moved then more will be needed.
  17. Tweaking

    Please Please Please make sure that if you are entering those screens and you happen to change anything you write down how it was before. I have gone on so many calls where the UI has been set and...
  18. Replies
    15
    Views
    8,464

    Ugh the "leak"

    1st tech out, press. test nothing.
    2nd tech out press. test nothing told him to add dye
    Finally I go out, for sure 400 psi would show leak, nothing, wip out the light YES attempted to show customer...
  19. Replies
    57
    Views
    13,563

    Leaking coil

    I work for a Carrier dealer in my area and have not had any issues with coil leaks since around 2000. It seems that this year I am running into 2 year old coils that have leaking TXV's on both r22...
  20. Replies
    2
    Views
    545

    Anything can be done, and as stated it could be...

    Anything can be done, and as stated it could be placed above the return box, also keep in mind that there are other types of aircleaners from different MFG. Depending on what brand of system is going...
  21. Seems to me like the contractor is going to put...

    Seems to me like the contractor is going to put in what ever he wants without the homeowners input, I think that the homeowner should be demanding in that event that he get some kind of extended...
  22. Replies
    12
    Views
    971

    Yeah and then i could take, it fix it, and if my...

    Yeah and then i could take, it fix it, and if my a/c goes out in my work truck make a hole in the side, hook it up to an inverter, and use it in my truck:D
  23. Replies
    12
    Views
    971

    How much to look at my window unit?

    I was working in the office today for a bit and a lady called up and asked me how much it would cost for us to come out and look at her window unit, I should of said just toss it and buy another, but...
  24. Replies
    16
    Views
    3,371

    I love it when people put roses around the units...

    I love it when people put roses around the units so that you cant get to them without stepping on them or scrathing yourself. Or when they leave nice loose dirt aroun em and the coil beggins to pack...
  25. Replies
    33
    Views
    1,799

    Ooops

    Wow, I was waiting for him to drop the bulb to see what they would do:)
  26. Replies
    9
    Views
    2,638

    And I second that:D

    And I second that:D
  27. Replies
    34
    Views
    3,262

    I use both the hoses with the ball valves on them...

    I use both the hoses with the ball valves on them and the adapter 90( I can't remember the brand)I love the ball valve type, even though just a pinch spits back out, but only use those on R410a,...
  28. Replies
    14
    Views
    9,080

    If the coil in the air handler is still available...

    If the coil in the air handler is still available keep in mind that you will be installing an R-22 coil. Have the compressor and the other electronics carefully inspected because it would be...
  29. Replies
    9
    Views
    660

    I've had those gauges since last year sometime, I...

    I've had those gauges since last year sometime, I dunno how you treat them but mine are still in very good condition I treat em like a baby when I bring em out. I mainly use them for R410a, oh by...
  30. Replies
    5
    Views
    692

    Super Seal

    Anyone have any comments good or bad on the SUPER SEAL leak sealant? Supposedly it repairs leaks when they are very minor and cannot be found!
    My employer is thinking of beggining use of it but I...
  31. Replies
    6
    Views
    1,463

    signing up for the pro forum i will try and as...

    signing up for the pro forum i will try and as for my spelling bought a new computer and declined the extended warranty and whaddaya know friggin computer keys sometimes fail!
  32. Replies
    17
    Views
    1,575

    Good point, We have a new guy who just began...

    Good point, We have a new guy who just began getting comfortable charging 410a units and he called me up asking questions and based on what he was telling me i told him he was still undercharged and...
  33. Replies
    17
    Views
    1,575

    calculators

    Carrier and most other dealers have these slide calculators available either for free or for a small fee I have found as i am sure most of the experienced techs have come to find that superheat based...
  34. Replies
    6
    Views
    1,463

    Low suction nd discharge pressures

    Any ideas will be great! I was doing a start up of an a/c due to having replaced the furnace but my pressures just were not right i had what were low pressures on both high and low side i dont have...
  35. Replies
    32
    Views
    2,886

    :mad:Man sounds kinda like a call I went to after...

    :mad:Man sounds kinda like a call I went to after a hot week a customer wanted to have a clean and check done just to make sure it is all ok, everything good but wants to make sure, get out there do...
  36. Replies
    7
    Views
    1,935

    the companies that i have worked for have been...

    the companies that i have worked for have been using that system now for awhile. I use them more or less as a guide, if job is standard i go with it, harder i go up, if very easy i go down. With...
  37. Replies
    4
    Views
    588

    The condensor is a comfort model 13 seer 2.5 ton...

    The condensor is a comfort model 13 seer 2.5 ton unit oh and r-22 model. see about changing it for a puron model if possible they are only a few bucks more!
  38. Thread: Wal-Mart

    by castillo7411
    Replies
    112
    Views
    7,421

    Just a thought, what if walmart went into the...

    Just a thought, what if walmart went into the HVAC trade/business?:eek:
Results 1 to 38 of 38
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event