  1. Replies
    16
    Views
    2,318

    Looks like Wye Delta starter with dash pots for...

    Looks like Wye Delta starter with dash pots for overloads,looks amazing
  2. Replies
    7
    Views
    433

    https://customer.honeywell.com/resources/techlit/T...

    https://customer.honeywell.com/resources/techlit/TechLitDocuments/60-0000s/60-2082.pdf

    Here is the webpage ..
  3. Replies
    4
    Views
    433

    You do not say anything about gas pressure, or...

    You do not say anything about gas pressure, or regulators? That is about all the info you are going to get on an open Forum.
  4. Replies
    20
    Views
    2,312

    Het Ammar you forgot the A on the end of...

    Het Ammar you forgot the A on the end of Canada. :grin2: Just a bit of Canadian humor from the west coast!!!!
  5. Thread: Hvac ductwork

    by DPinst
    Replies
    3
    Views
    440

    Thank you very much for the information ,greatly...

    Thank you very much for the information ,greatly appreciated.
  6. Thread: Hvac ductwork

    by DPinst
    Replies
    3
    Views
    440

    Hvac ductwork

    Is there a website or even a book that will provide guidelines for commercial HVAC ductwork installation? An example where is the best place to install balancing dampers, max length of flex...
  7. Replies
    16
    Views
    1,047

    Had a similar issue in a food processing plant it...

    Had a similar issue in a food processing plant it turned out the socks were dirty. To visually inspect them they looked fine but lack of airflow pointed to restriction. Had the socks cleaned and...
  8. Replies
    15
    Views
    1,135

    You need to get the Lennox OEM as other people...

    You need to get the Lennox OEM as other people have stated .You will find that lennox name plates are missleading. The motor you require for that unit is actually a 1 hp universal motor if you match...
  9. Google, cps products "The run capacitor for the...

    Google, cps products "The run capacitor for the compressor" great article
  10. Replies
    3
    Views
    322

    How dirty is the condenser coil, also check the...

    How dirty is the condenser coil, also check the airflow across the condenser ,is the air short cycling ,is it getting enough air, you may have to cut a bigger grill for the condenser to get enough...
  11. Replies
    13
    Views
    569

    Assuming that you are rated at 208 volts , I...

    Assuming that you are rated at 208 volts , I would look at trying to improve your voltage. You only have 86% starting torque available .
  12. So they will run the compressor at full capacity...

    So they will run the compressor at full capacity and slow the air flow down. They are anticipating an increase in Evap TD which will cause the amount of Latent heat removed ie moisture to increase...
  13. Replies
    17
    Views
    1,375

    I have always asked the customer: 1-How much is...

    I have always asked the customer:
    1-How much is one of your towers worth?What will it cost if it crashes because of overheating?
    2- How much money will you lose if your servers go down because you...
  14. Thread: Alberta work

    by DPinst
    Replies
    1
    Views
    478

    Look on UA 488 website for work in Alberta . they...

    Look on UA 488 website for work in Alberta . they have postings for both Fort Mac and Calgary,Edmonton
  15. Replies
    5
    Views
    561

    I think they may be saying that the problem is...

    I think they may be saying that the problem is with the communication cable itself ,not the type of cable.
  16. Replies
    5
    Views
    2,497

    Thank you for the reply, I am still looking for...

    Thank you for the reply, I am still looking for the slides.
  17. Thread: pneumatics

    by DPinst
    Replies
    12
    Views
    701

    In regards to heat pumps ,do they fail to heat or...

    In regards to heat pumps ,do they fail to heat or cool?
    In The great white north some of our water source heat pumps do fail to heat (Climate master ) While others fail to cool.
    Our air to air...
  18. Replies
    7
    Views
    911

    CJPwalker may be onto something. Are they using...

    CJPwalker may be onto something. Are they using flexible connectors for the gas? If so you will probably have to hard pipe the gas line. 15 years ago had a new install, that this was an issue with...
  19. Replies
    5
    Views
    790

    Check this site for information about this...

    Check this site for information about this problem. I seem to remember it had to do with positioning the motor and how the airflow was blowing the pilot flame off the flame rod.
  20. Replies
    15
    Views
    1,419

    Just make sure that the pre purge and the lock...

    Just make sure that the pre purge and the lock out timing is the same. Also make sure to match the # of times it can try for ignition. Replaced a lot of Johson with Honeywell S86 .
  21. Thread: Kablooey!!

    by DPinst
    Replies
    23
    Views
    5,016

    Hope you still have your ebrows there Karl. How...

    Hope you still have your ebrows there Karl. How are things these days at the big E
  22. Replies
    5
    Views
    2,497

    Carrier Fundamentals of refrigeration

    I have inherited an old set of Books from Carrier "Fundamentals of Refrigeration" it appears to be a home study course that came with slides ,(yes slides for you youngsters google it,it was our power...
  23. Replies
    47
    Views
    5,527

    Centrifugal switch on the ventor motor ,roll out...

    Centrifugal switch on the ventor motor ,roll out switch ,or high limit could be the reason for no power to the module. As to not lighting sometimes the spark generated by the module is incorrect and...
  24. Replies
    1
    Views
    923

    The fan control is not run throught the...

    The fan control is not run throught the Honeywell w 973 panel. It is a seperate 24 volt circuit.

    If it has a switching subbase the contacts will be # 9-10 on the subbase it will be connected to C...
  25. Usually small evaporators use fractional...

    Usually small evaporators use fractional horsepower psc motors. When you reduce the HP by changing the taps you are not reducing the input voltage.
    Get out your ohm meter and ohm out a PSC motor...
  26. Replies
    6
    Views
    1,015

    As mrhavacmechanic stated look into the ICM...

    As mrhavacmechanic stated look into the ICM control , make sure it is set for the type of bearings you have in the motor.
    All that will happen ,is a sleeve bearing will go to full speed for a brief...
  27. Replies
    5
    Views
    1,636

    Simulator

    THe simulator is the best option for servicing the w-973 panel.
  28. Replies
    13
    Views
    2,749

    http://www.handsdownsoftware.com/Downloads.htm ...

    http://www.handsdownsoftware.com/Downloads.htm


    By taking the entering conditions and the leaving conditions ,using the psychrometric chart you should be able to graph the ADP ,which is just your...
  29. Replies
    52
    Views
    4,848

    Try running 2nd stage as first stage and see what...

    Try running 2nd stage as first stage and see what your readings are . It may point you towards an an airflow issue.
  30. Replies
    0
    Views
    687

    Emerson Motor pro training

    They used to have this on their website ,but now I am unable to find it ,If I google it it takes me to US motors and they say it will be up and running soon.
    Is it still available ? I find it very...
  31. Replies
    15
    Views
    2,040

    Corner Ground

    Corner ground !!!
    That is the first explanation of this voltage reading that make some sense.
    Have had some older buildings that you read your meter and have to take a second look because you do...
  32. Replies
    21
    Views
    1,745

    What kind of system is it on? Is there dampers...

    What kind of system is it on? Is there dampers that open or close causing a reduction in static pressure ?
  33. Replies
    11
    Views
    1,646

    http://www.journalofcommerce.com/article/id33548...

    http://www.journalofcommerce.com/article/id33548

    This article may be of interest to ,instead of using the well water you may be able to extract the heat from the sewage pond. Trane has developed...
  34. Replies
    5
    Views
    742

    That is the reason why DRIP legs are installed to...

    That is the reason why DRIP legs are installed to trap any dirt or oil in the piping. As Rieck-Tech2 said somebody got carried away with the cutting oil when he was threading pipe.
  35. Replies
    9
    Views
    4,695

    In some older parts of the city used to see the...

    In some older parts of the city used to see the same issue with water in gas lines. This was due to the line pressure being below below 7" w.c. and piping buried below ground to meet code. If you...
  36. Thread: Ice Rink Piping

    by DPinst
    Replies
    2
    Views
    661

    Ice Rink Piping

    There was a link for piping for ice rinks posted a while ago. I have lost the link and was wondering if anybody remembers what it was. Any help would be appreciated.
  37. Replies
    14
    Views
    1,376

    In Canada the rules regarding purging with HCFC...

    In Canada the rules regarding purging with HCFC are very clear you can not. As what was also pointed out the cost of r-22 and if you are brazing you should be purging with nitrogen. You should have...
  38. Replies
    21
    Views
    3,616

    1,1-Difluoroethane is an organofluorine compound...

    1,1-Difluoroethane is an organofluorine compound with the chemical formula C2H4F2. This colorless gas is used as a refrigerant, where it is often listed as R-152a or HFC-152a. As an alternative to...
  39. Replies
    21
    Views
    3,616

    152-A main component is Ethane and I would be...

    152-A main component is Ethane and I would be more concerned with an contacting an open flame than ODP(which is zero). Google it and read the warnings
  40. Replies
    11
    Views
    3,251

    These valves are non adjustable,be carefull...

    These valves are non adjustable,be carefull because if you remove the cap you will lose your charge. Unfortunately they do not warn you anywhere in the units
  41. Replies
    22
    Views
    2,595

    Do not rule out the reversing valve just because...

    Do not rule out the reversing valve just because of age of unit.
    When unit was running did you measure the temperatures of the suction line entering and exiting the reversing valve? If you have a...
  42. Replies
    17
    Views
    3,330

    Have seen a condensor that the water froze...

    Have seen a condensor that the water froze inside.The end result was that the water froze expanded and the condensor required replacing as it had zero water flow.
  43. Replies
    58
    Views
    7,221

    Have you been able to varify airflow across the...

    Have you been able to varify airflow across the burner?
    You may have a air pressure switch that is not set correctly and causing you problems.
  44. Replies
    3
    Views
    864

    With DSI controls there is a lock -out if flame...

    With DSI controls there is a lock -out if flame is not sensed after a very short time( 2.5 seconds ) period. I can not be changed as it is a safety control.
    Think about what would happen if the gas...
  45. Replies
    24
    Views
    1,568

    Canadian gas code requires combustion air for the...

    Canadian gas code requires combustion air for the appliance.That is the purpose of the duct.There should a grill in the supply air that supplies air into the room that the furnace is in. There is...
  46. Thread: GPS in trucks

    by DPinst
    Replies
    31
    Views
    1,949

    GPS in trucks

    OK here we go. Contractors in Vancouver are beginning to install GPS in their vehicles. The reaction is mixed.
    What are some of ther experiences in the rest of the HVAC world ?
  47. Replies
    1
    Views
    1,612

    What is used to prove the combustion blower motor...

    What is used to prove the combustion blower motor is running .It is either an air proving switch or a centrifugal switch on the comb blower motor. That could be a cause of your problem. The motor...
  48. http://www.apscontrols.ca/basic%20controls%202.pdf...

    http://www.apscontrols.ca/basic%20controls%202.pdf.
    Try this link
  49. Replies
    2
    Views
    1,108

    Is the original unit Direct spark ignition?

    Is the original unit Direct spark ignition?
  50. Replies
    17
    Views
    2,662

    It is scary that a fault such as a roll out...

    It is scary that a fault such as a roll out switch can be reset with out a visual inspection.As was stated before these heat exchangers are famous for rotting out.
    You did not say whether the...