Search:

Type: Posts; User: manny238

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    241

    On YouTube there is plenty information. ...

    On YouTube there is plenty information.


    Sent from my iPhone using Tapatalk
  2. Replies
    16
    Views
    3,806

    60+ year old Trane Centravac

    Work horse. Good looking machine.


    Sent from my iPhone using Tapatalk
  3. Not much man just trying to keep busy. Haha I...

    Not much man just trying to keep busy.

    Haha I hear that. The general must be losing some hair on this job.

    Is that the job where they overcharged every unit with oil?

    Glad to see your...
  4. What a bummer for new equipment. You should ask...

    What a bummer for new equipment. You should ask for there start up logs for a good laugh.


    Sent from my iPhone using Tapatalk
  5. Replies
    25
    Views
    1,699

    Not so bad when u can park next to the unit. ...

    Not so bad when u can park next to the unit.


    Sent from my iPhone using Tapatalk
  6. Replies
    5
    Views
    673

    Check to ensure the compressor u actually have is...

    Check to ensure the compressor u actually have is configured into the UCP control panel.


    Sent from my iPhone using Tapatalk
  7. Replies
    84
    Views
    4,604

    Prolly a recip compressor your installing. I...

    Prolly a recip compressor your installing. I believe it's just another port to your suction side of the compressor. You can either braze it shut or braze a fitting on so u can gauge up there.
  8. Replies
    84
    Views
    4,604

    Why is your boss going back with a 5 ton...

    Why is your boss going back with a 5 ton compressor?
  9. Replies
    84
    Views
    4,604

    X2

    X2
  10. It's nothing audible It's just a red light and...

    It's nothing audible It's just a red light and alarm notice on the unit controller. Doesn't shut down the unit just gives u a warning/alarm that the filters may need service.

    As far as what...
  11. It has a pressure differential switch that looks...

    It has a pressure differential switch that looks at pressure across the filters.
  12. I've had the pins get real corroded on the...

    I've had the pins get real corroded on the control boards and cause all sorts of problems. Just something you might wanna look into. They usually get real discolored as well.
  13. Replies
    84
    Views
    4,604

    Trane compressor not coming on

    Have u tried megging the
    Compressor?
  14. I used to love using bungie cords but in arizona...

    I used to love using bungie cords but in arizona they only last a couple of weeks in the summer.
  15. Thread: Just wow

    by manny238
    Replies
    13
    Views
    2,440

    At least it held for a while. Lol. Just crazy!

    At least it held for a while. Lol. Just crazy!
  16. Replies
    9
    Views
    630

    Yeah I try to make it a habit to replace the...

    Yeah I try to make it a habit to replace the check valves and driers if I have any suspicion of a restriction.......Especially on those Carrier package heat pumps with the header metering device.
  17. Replies
    9
    Views
    630

    I'm pretty sure those check valves have screens...

    I'm pretty sure those check valves have screens in them.
  18. Replies
    27
    Views
    6,343

    thats just wrong.

    thats just wrong.
  19. Replies
    4
    Views
    1,755

    Looks like a DSC service call.

    Looks like a DSC service call.
  20. wow. stuff like this just doesnt suprise me...

    wow. stuff like this just doesnt suprise me anymore
  21. Replies
    4
    Views
    1,314

    Reminds me of those dreadful apartment complex...

    Reminds me of those dreadful apartment complex mechanical rooms
  22. Replies
    4
    Views
    911

    1964 Trane Chiller

    Thought some of you guys might appreciate this picture. 1964 Trane chiller still putting in some work. Been updated from old pneumatic controls to new Trane panel. Performing a leak search and...
  23. Replies
    6
    Views
    1,315

    Seems like maybe the IFM wasnt programmed/wired...

    Seems like maybe the IFM wasnt programmed/wired correctly at start up.
  24. I contacted sporlan and they gave me a part...

    I contacted sporlan and they gave me a part number. Then I went to parts house (American Refrigeration Supplies) and ordered it. I received it pretty quick.

    Ill look around to see if I have...
  25. i always ordered mine directly from sporlan...

    i always ordered mine directly from sporlan
    http://i31.photobucket.com/albums/c381/allshow98/image.jpg
    http://i31.photobucket.com/albums/c381/allshow98/image_4.jpg
  26. Replies
    18
    Views
    3,872

    what a pain in the a55 it is to replace those...

    what a pain in the a55 it is to replace those coils but i was able to fix the leak just for temp cooling till i recieved the warranty coils. its funny...every single coil had a refrigerant leak....
  27. Replies
    16
    Views
    1,350

    And maybe a airflow issue. That 52 degree suction...

    And maybe a airflow issue. That 52 degree suction line temp sounds sketchy with high sub cooling.
  28. Replies
    16
    Views
    1,350

    Is your compressor over amping? Sounds like you...

    Is your compressor over amping? Sounds like you have a restriction with a overcharge.
  29. Replies
    10
    Views
    1,717

    Carrier micro channel coils are keeping me pretty...

    Carrier micro channel coils are keeping me pretty busy these days.
  30. Nah man sorry.

    Nah man sorry.
  31. Thread: NO AC CALL

    by manny238
    Replies
    23
    Views
    3,832

    Lol. Wow that's messed up

    Lol. Wow that's messed up
  32. This clown hear even has a video teaching...

    This clown hear even has a video teaching customers how to replace condenser motors.
    http://phoenix.craigslist.org/evl/fod/3745268807.html
  33. There's some hack here in Phoenix that pulls...

    There's some hack here in Phoenix that pulls that crap. Of course he's gonna save the customer money if he has no overhead. Damn hacks !
  34. Replies
    10
    Views
    2,090

    thanks for posting these cool pictures. most of...

    thanks for posting these cool pictures. most of been a nice job
  35. Replies
    8
    Views
    2,144

    Nope the ball bearing would not move...... also...

    Nope the ball bearing would not move...... also ran numerous test on the IGV it would not respond at all.
  36. Replies
    8
    Views
    2,144

    The IGV was stuck at 20% it would not open or...

    The IGV was stuck at 20% it would not open or close.

    I just realized I posted in the wall of shame Can someone move it to the commercial forum.
  37. Replies
    8
    Views
    2,144

    Smardt Chiller Repair - Turbocor

    This was my first repair on a turbocor compressor. The IGV on compressor #1 stop responding.......couple months later compressor #2 IGV stop responding and got stuck in a fixed position just like #1...
  38. Replies
    7
    Views
    1,626

    Damn what a mess. Are you even able to remove the...

    Damn what a mess. Are you even able to remove the blower door panel? Looks pretty tight
  39. Replies
    19
    Views
    3,190

    wow. at first sight i thought that was one of...

    wow. at first sight i thought that was one of those copper flexable pipes you would use on water heater lines. good thing you weren't around when that thing went off
  40. Thread: WSHP issue

    by manny238
    Replies
    15
    Views
    1,910

    Yeah I agree with grkmano. If u have a control...

    Yeah I agree with grkmano. If u have a control valve for your condenser water it might be closing on you. Also need to check your circuit setter if u have one to make sure it's not restricting your...
  41. Thread: WSHP issue

    by manny238
    Replies
    15
    Views
    1,910

    cool or heat mode? you have any pressure readings?

    cool or heat mode? you have any pressure readings?
  42. Replies
    0
    Views
    669

    Carrier Electronic Flow Sensor

    Does anybody know if there is a service bulletin for these sensors. Carrier told me they have been having trouble with these sensors. Noticed they changed the design a little. If there is a bulletin...
  43. Replies
    4
    Views
    1,377

    You should be able to force the EXV open If you...

    You should be able to force the EXV open If you know how to put the system into test mode.
  44. Replies
    14
    Views
    1,899

    damn i cant believe someone would do such a...

    damn i cant believe someone would do such a thing. idiots
  45. Thread: more winners

    by manny238
    Replies
    10
    Views
    2,336

    wow. what a mess

    wow. what a mess
  46. Replies
    13
    Views
    2,701

    How did your units get overcharged or...

    How did your units get overcharged or undercharged? I just finished installing 3 citymulti units they made me measure my liquid line by length and size so they can provide me with the amount of...
  47. Your best bet would be to contact Carrier tech...

    Your best bet would be to contact Carrier tech support or read the installation manual. Like heatingman said a LL valve would be a good idea
  48. Replies
    71
    Views
    13,089

    Wow. thanks for sharing the pics. I would love to...

    Wow. thanks for sharing the pics. I would love to do a tear down like that. nice job!
  49. Replies
    11
    Views
    3,042

    lol wow... i dont see anything wrong here. next!

    lol wow... i dont see anything wrong here. next!
  50. Thread: The goods

    by manny238
    Replies
    7
    Views
    1,531

    No not at all there is plenty of splits around...

    No not at all there is plenty of splits around here. Sometimes I wish there were more rooftop units. When i used to do residential i always hated crawling in attics in the middle of the summer to do...
Results 1 to 50 of 407
Page 1 of 9 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event