Search:

Type: Posts; User: MatrixTransform

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    9
    Views
    268

    Pie isn't available in the chart pallette but is...

    Pie isn't available in the chart pallette but is Definately in the jar file. I have made it work before but can't remember how exactly. I do recall it needs a single row of data though.

    More...
  2. Replies
    2
    Views
    209

    Yeah, they're kinda hokey. I use a program object...

    Yeah, they're kinda hokey. I use a program object every time in preference.

    If you gimme a idea of what you want to achieve I can help you out
  3. Replies
    44
    Views
    2,322

    LOL...come 'ere boy...*whistles*...rover c'mon....

    LOL...come 'ere boy...*whistles*...rover c'mon. Good doggy. Rover?...Rover!..ROVER! dammit.

    ...ask Trane where yr dog is
  4. Replies
    44
    Views
    2,322

    Hmmm, I worked for Trane for a short and painful...

    Hmmm, I worked for Trane for a short and painful time.

    no real need for the gasolene ... try connecting with a laptop that isnt 'Trane-ified"... Im sure it will try to ring head office and then...
  5. Replies
    22
    Views
    1,576

    I reckon Moneywell should be happy to have their...

    I reckon Moneywell should be happy to have their brand so proudly displayed on a showcase job like this... At least most of the LEDs are on.
  6. lonmaker rocks!

    lonmaker rocks!
  7. these are LON controllers and as such, the...

    these are LON controllers and as such, the transceiver, network interface and, physical medium are pretty much manufacturer independent.

    I would suggest that your issues are due to network and...
  8. Replies
    13
    Views
    999

    My opinion upsets you ...and ...and...and ...you...

    My opinion upsets you ...and ...and...and ...you think Im 'starting' something?

    Lemme get this straight ... you ask the question about licensing in the first place (but apparently you already do...
  9. Replies
    13
    Views
    999

    ...so you believe you have been operating...

    ...so you believe you have been operating unlicensed?

    I would have thought it prudent and less risky to sort out issues like that before investing in the business of controls.

    Just saying.
  10. Replies
    7
    Views
    579

    If the DX9100 is a version ????, then what you'll...

    If the DX9100 is a version ????, then what you'll need to do is unplug it from the ???? and use a ???? to format the ram around address ????.

    If that doesn't work telephone support on ???-???-????...
  11. Replies
    13
    Views
    999

    What, at making the joke? or telling the truth? ...

    What, at making the joke? or telling the truth?

    ... this is like courting a vampire.

    Good luck in the controls world my friend.
  12. Replies
    13
    Views
    999

    I have a great idea ... Why dont you just ask...

    I have a great idea ...

    Why dont you just ask the question of all other mech guys in yr area that already think they can do do controls?

    ...I'm sure they'd know

    ...or think they know

    a...
  13. for time setting, there would probably be a way...

    for time setting, there would probably be a way via programming.

    the supervisor can be a master and the Jace can be a slave ...and vice versa.

    dunno about both ways!
  14. those who have it are under a gag-order. ...

    those who have it are under a gag-order.

    ...you may have to wait for JCI
  15. Replies
    7
    Views
    434

    the people who want a copy, please private...

    the people who want a copy, please private message me ... I need to know where you are in the world before sending.

    Sorry but this is IP that brings us a competitive advantage...I dont like...
  16. Replies
    7
    Views
    472

    private message me ... we have solution for you

    private message me ... we have solution for you
  17. Replies
    7
    Views
    434

    checked yr mail?

    checked yr mail?
  18. Replies
    7
    Views
    434

    ...as in building ComponentGrids? ...or adding...

    ...as in building ComponentGrids?

    ...or adding a Table with a table binding from bajaUI to a Px page?

    both above are ok for BQL queries that dont change

    Problem with both the above methods...
  19. Well, thats a no brainer ...FT10 of course!

    Well, thats a no brainer ...FT10 of course!
  20. Replies
    6
    Views
    592

    Um, it ain't hype. Tritium talks to pretty much...

    Um, it ain't hype. Tritium talks to pretty much everything. 5 protocols running concurrently in the same controller...no prob. The framework is extensible and open.
  21. ...normal behaviour for FEC isnt it?

    ...normal behaviour for FEC isnt it?
  22. Replies
    32
    Views
    1,610

    ...not true Im afraid....in LON there really isnt...

    ...not true Im afraid....in LON there really isnt a 'managing' device

    devices can exist in multiple domains.
    can be polled or bound.

    there is no reason whatsoever you cannot have multiple...
  23. Replies
    32
    Views
    1,610

    if theyre commissioned with AUth then I believe...

    if theyre commissioned with AUth then I believe the only way to get around it is to get the key from the original commissioning tool .

    but yeah make sure your key in AX is all null (FF)...
    ...
  24. Replies
    32
    Views
    1,610

    100 ohm may not be the correct value. Depends on...

    100 ohm may not be the correct value. Depends on lots of things. I would go armed with resistors from 50 to 150. Also the Lon spec asks for a bipolar cap in series with the resistor...can't remember...
  25. Replies
    32
    Views
    1,610

    yeah, check the binding type and make sure they...

    yeah, check the binding type and make sure they aren't ack bindings.

    You may want to check the DSN of all devices. I have noticed JCI devices can often be spread over different subnet addresses.
    ...
  26. Replies
    32
    Views
    1,610

    I have usually found that jci are very good at...

    I have usually found that jci are very good at making resilient master devices that cope with scrappy install and poor set up and config. Put a real Lon device (or bacnet) on a network to replace the...
  27. ...?

    ...?
  28. Replies
    11
    Views
    630

    any voltage input to a DDC controller should...

    any voltage input to a DDC controller should probably be in the >20k range which would not put much load on a circuit.

    ...careful, though most wont care, some controllers dont like their voltage...
  29. Replies
    8
    Views
    2,269

    could be lots of reasons. 1: maybe youre...

    could be lots of reasons.

    1: maybe youre trying to send to a mail server not controlled by the ISP yr connected via.(pretty much all ISP will NOT relay mail)
    2: authenticated v not
    3: ports...
  30. Replies
    33
    Views
    6,123

    google ... for example ... condenser water and...

    google ... for example ... condenser water and wetbulb

    and variations of this can bring up some interesting papers.

    Lots of information in some papers regarding optimal, and calculations for...
  31. Replies
    33
    Views
    6,123

    Sue me

    Sue me
  32. Replies
    33
    Views
    6,123

    what a load of old bollocks. the patent would...

    what a load of old bollocks.

    the patent would be on the method, the code, the algorithm...not using PD or CH power as a metric.

    The rest are general principles.

    if anybody is stupid enough...
  33. guessing Spy settings? Maybe somebody turned...

    guessing Spy settings?

    Maybe somebody turned on the trace for the Fox service
  34. Replies
    28
    Views
    1,641

    ...mate, you need help with reading ...not math!...

    ...mate, you need help with reading ...not math!


    No


    No
  35. Replies
    28
    Views
    1,641

    Two drums and cymbal fall off a cliff .... ...

    Two drums and cymbal fall off a cliff ....

    ...

    ...

    ...

    boom, boom...
  36. Replies
    28
    Views
    1,641

    You lot are very funny typical fridgies ......

    You lot are very funny
    typical fridgies ... youre outta ya depth and want something from a sparky for free.
    I should tell ya's get stuffed ... we are COIN OPERATED here you know!

    Voltage Drop...
  37. Replies
    17
    Views
    1,304

    Omg...its not a case of which is better. My ex...

    Omg...its not a case of which is better.

    My ex father in law was a jet pilot. I once expressed my concerns to him at flying around the Aussie desert in a single engine low wing junkbox with a...
  38. Wrong property...not the 'summary' field that...

    Wrong property...not the 'summary' field that needs changing...its the 'text' field
  39. Replies
    4
    Views
    442

    Sounds like another fridgy generating new...

    Sounds like another fridgy generating new business from chiller rebuilds.
  40. Replies
    12
    Views
    740

    Maybe sometimes the screen/drain is the antenna...

    Maybe sometimes the screen/drain is the antenna for reasons unknown...install practices unseen etc. We have pretty good success in many mstp and Lon networks taking shield to ground but via an RC...
  41. Replies
    1
    Views
    268

    It must be on the jace. Plat connect. File...

    It must be on the jace.
    Plat connect.
    File transfer
  42. Replies
    6
    Views
    444

    Flow x Cp x td...more or less

    Flow x Cp x td...more or less
  43. Replies
    19
    Views
    941

    Omg...I've been paraphrased!

    Omg...I've been paraphrased!
  44. Replies
    16
    Views
    1,078

    ...and yr problem isnt calibration....more likely...

    ...and yr problem isnt calibration....more likely the tech that programmed it doesnt know how to make a vav work properly.

    I make a very good business out of 'fixing' other people's VAV control...
  45. Replies
    16
    Views
    1,078

    Omg...it's a DDC controller with a thermistor...

    Omg...it's a DDC controller with a thermistor attached...this isn't Rocket Surgery. There will be some relative error and repeatability errors but they will be small. Cannot see why you couldn't be...
  46. Replies
    14
    Views
    631

    Dwyer? United electric?

    Dwyer?
    United electric?
  47. Replies
    5
    Views
    376

    1. Are LON networks truly "Interoperable"? In...

    1. Are LON networks truly "Interoperable"? In other words if a Honeywell LON controller fails can it be replaced with say a Metasys LN Series controller without any real problems?

    --yes. though...
  48. very do-able can build it in a programObject as...

    very do-able
    can build it in a programObject as well. bit of a cpu blocking hog though...Id do it with threads

    open history(s) with bql(s).
    make cursor(s)
    step through and write to a file, or...
  49. Replies
    3
    Views
    635

    ...a program called XPSI for the ASD devices ...

    ...a program called XPSI for the ASD devices

    and NUDL for the GCM
  50. Replies
    2
    Views
    231

    Kaos meet Kontrol

    Kaos meet Kontrol
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image