Search:

Type: Posts; User: coldking

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    39
    Views
    7,056

    Doesn't Hoshi press them in? I've always sent the...

    Doesn't Hoshi press them in? I've always sent the used one back and they sent me one that was already pressed in.
  2. Replies
    11
    Views
    1,034

    Put ice in the bin to help cool the ice section.

    Put ice in the bin to help cool the ice section.
  3. Replies
    24
    Views
    4,724

    Works fine in Firefox for me. Make sure your...

    Works fine in Firefox for me. Make sure your router isn't set to block things
  4. Wouldn't this make your company liable for any...

    Wouldn't this make your company liable for any damage or injury? That equipment had to be certified for safety before it could be marketed. Altering the way the equipment performs would most likely...
  5. Replies
    14
    Views
    1,710

    Sporlan CAPT-032 works well haven't had the...

    Sporlan CAPT-032 works well haven't had the repeat restrictions that seem to happen with those copper spun driers.
  6. Replies
    6
    Views
    855

    I have worked on several of them. They aren't too...

    I have worked on several of them. They aren't too bad as long as you have the troubleshooting info. They have the filter for the condenser that no one ever cleans. I think the fin space on the...
  7. Thread: metal filters

    by coldking
    Replies
    14
    Views
    1,612

    I have seen them in many manufactured homes, they...

    I have seen them in many manufactured homes, they basically lay on each side of the A coil. They don't work very well either. I have installed a filter grill above the air handler and sealed off the...
  8. Replies
    4
    Views
    1,977

    Be sure all lines are clear. We have seen places...

    Be sure all lines are clear. We have seen places not filter until the vat has a lot of breading in them, this causes the lines to plug up. I had a new fryer delivered with the lines connected wrong...
  9. Replies
    26
    Views
    2,294

    how often does it happen? Need more info

    how often does it happen? Need more info
  10. Replies
    43
    Views
    2,635

    I think you got it. You and I think alot alike, I...

    I think you got it. You and I think alot alike, I started asking them questions when they did wrong to teach them to think before they do or say things and what the consequences are for those...
  11. Thread: work vans

    by coldking
    Replies
    21
    Views
    1,634

    Everything has its place, customer pays for me to...

    Everything has its place, customer pays for me to use they pay for it to be returned to its proper place. I have an master inventory sheet and keep a list of parts used each day and return them next...
  12. Replies
    7
    Views
    928

    This is the best advice we can give you from here

    This is the best advice we can give you from here
  13. Thread: sliver king

    by coldking
    Replies
    7
    Views
    1,175

    http://www.silverking.com/

    http://www.silverking.com/
  14. Replies
    20
    Views
    4,581

    There is a second level over top of these for the...

    There is a second level over top of these for the next floor
  15. Replies
    20
    Views
    4,581

    Can you install another unit here?

    [attach]2564[/attach
  16. Replies
    30
    Views
    5,594

    Around here the power company would be on the...

    Around here the power company would be on the phone to the inspector.
  17. Replies
    6
    Views
    1,003

    Are you set on doing market refrigeration or open...

    Are you set on doing market refrigeration or open to working on smaller commercial refrigeration?
  18. Replies
    16
    Views
    2,422

    I doubt that flex duct is insulated. Flex duct...

    I doubt that flex duct is insulated. Flex duct straight from air handler isn't a sign of good duct design. I would definitely have the duct work addressed no matter what system you choose.
  19. Replies
    20
    Views
    7,975

    Talk with Joe or Julie with Captive Air they have...

    Talk with Joe or Julie with Captive Air they have never done me wrong
  20. Replies
    12
    Views
    1,196

    I have aways seen 00 for 110V

    I have aways seen 00 for 110V
  21. Replies
    9
    Views
    1,025

    We bought a roll of the white membrane roofing...

    We bought a roll of the white membrane roofing from a roofing supplier 10' x 100' for what the cooler manufactures wanted for 10' x 30'
  22. Thread: Bev air crap?

    by coldking
    Replies
    6
    Views
    789

    worked on a beverage air 3 door freezer last year...

    worked on a beverage air 3 door freezer last year brand new off the truck plugged unit in left unit operate empty for 2 days customer calls says unit still not below 38
    Temperature control looked...
  23. Replies
    6
    Views
    964

    Heatpump will work fine. Here on the Outer Banks...

    Heatpump will work fine. Here on the Outer Banks NC there is many houses with little or no insulation and they work fine. Make sure your contractor does a heat loss/gain calculation.
  24. Replies
    28
    Views
    2,528

    The only thing I would like to see from Hoshi is...

    The only thing I would like to see from Hoshi is an easier way to clean the evaporator. The water quality here on the OBX isn't very good not to mention the owners that don't do regular maintenance....
  25. Replies
    28
    Views
    2,528

    I have had nothing but great support from Hoshi....

    I have had nothing but great support from Hoshi. Hoshi water pumps are quite pricey but they are great machines.I like their warranty too.
    Best part about them is I haven't seen many retrofits for...
  26. Thread: Ben & Jerry's

    by coldking
    Replies
    35
    Views
    2,584

    try this link...

    try this link http://www.benjerry.com/our_company/sounds_cool/
  27. Replies
    18
    Views
    4,004

    nitrogen is cheap compared to repairing unit...

    nitrogen is cheap compared to repairing unit under warranty
  28. Replies
    19
    Views
    2,946

    I bought the Klien 18" from Lowes.

    I bought the Klien 18" from Lowes.
  29. Replies
    6
    Views
    2,999

    I wish I had stock in that mastic company. I was...

    I wish I had stock in that mastic company. I was at a job the other day that had about 80' of 16" galvanized duct on an exposed roof coated with lots of mastic. I'll try to get pictures next chance I...
  30. Thread: Thermo-Flow

    by coldking
    Replies
    4
    Views
    1,356

    It is a model 600. Leaking around the recover/...

    It is a model 600. Leaking around the recover/ self evac valve and the discharge valve.
    Refco is mailing me the replacement gaskets as of Friday.

    Thanks for your help
  31. Thread: Thermo-Flow

    by coldking
    Replies
    4
    Views
    1,356

    unit is leaking around the knobs. I don't have...

    unit is leaking around the knobs. I don't have the machine with me right now will look when I get to the shop
  32. Thread: Thermo-Flow

    by coldking
    Replies
    4
    Views
    1,356

    Anyone Know where to get parts for Thermo-Flow...

    Anyone Know where to get parts for Thermo-Flow refrigerant recovery machines?
  33. Replies
    16
    Views
    1,349

    originally posted by Len hell man six...

    originally posted by Len

    hell man six years,that baby doesn't owe you anything,ive got some coolers out there that do not last 2 years.if the condenser doesn't get cleaned on a regular basis,then...
  34. Replies
    17
    Views
    1,440

    I give it nine days, I saw this on a similar...

    I give it nine days, I saw this on a similar McCall box
  35. Thread: Return Grill

    by coldking
    Replies
    8
    Views
    2,941

    http://img485.imageshack.us/img485/7331/dscf0488jb...

    http://img485.imageshack.us/img485/7331/dscf0488jb5.jpg
  36. Replies
    3
    Views
    2,486

    Original installer actually wrapped the duct...

    Original installer actually wrapped the duct board with fiberglass matting
  37. Replies
    3
    Views
    2,486

    Old oil Burner...

    Old oil Burner
    http://img207.imageshack.us/img207/8718/dscf0478qq4.jpg
    State of the art supply plenum
    http://img451.imageshack.us/img451/3198/dscf0479wz2.jpg
    The matching supply contraption...
  38. Replies
    12
    Views
    1,772

    I agree scrap the cap tube and use a txv.

    I agree scrap the cap tube and use a txv.
  39. Thread: MNF sucks

    by coldking
    Replies
    12
    Views
    848

    The games have been bad,but Theisman, Kornhole,...

    The games have been bad,but Theisman, Kornhole, and Tirico are horrible in the booth. Theisman can't decide which side of anything he wants to be on, its always the winning side in the end. He thinks...
  40. Replies
    8
    Views
    1,527

    Captive Air

    Captive Air
  41. Replies
    9
    Views
    1,751

    Case parts has one listed for Traulsen, here is...

    Case parts has one listed for Traulsen, here is the link:
    http://www.caseparts.com/block.asp?PBID=768
  42. Replies
    19
    Views
    1,586

    I would love to go back to R-12 on the boxes...

    I would love to go back to R-12 on the boxes around here but its just too pricey for my customers.

    I agree Icemeister is correct
  43. Replies
    10
    Views
    1,843

    Condenser too close to gas meter for around here....

    Condenser too close to gas meter for around here.
    I also agree with Bald and Mayguy about the lineset and plywood. Nothing worse than having to balance on a 2 x 4 to service a unit
  44. Replies
    19
    Views
    4,957

    I like to insulate the condensate line when in an...

    I like to insulate the condensate line when in an attic
  45. Replies
    4
    Views
    836

    What about Southern Stainless boxes?

    What about Southern Stainless boxes?
  46. Thread: True door ice

    by coldking
    Replies
    13
    Views
    1,243

    Went to one of these last week, customer couldn't...

    Went to one of these last week, customer couldn't understand the excess ice in his unit. I was there all of 30 seconnds and knew what the problem was. Customer put box in 8 x 10 room with no exhaust...
  47. Replies
    30
    Views
    10,527

    I had a Ruud that looked like that after 9 months...

    I had a Ruud that looked like that after 9 months on the ocean front
  48. Replies
    22
    Views
    1,155

    I would buy LCD, plasma sets have no warranty. A...

    I would buy LCD, plasma sets have no warranty. A friend bought a plasma at christmas by mid January it stopped working when he contacted the store he bought it from they told him to contact the...
  49. Replies
    10
    Views
    1,018

    THe S models are easier to clean

    THe S models are easier to clean
  50. Replies
    15
    Views
    1,399

    I had one that was having the same problem,...

    I had one that was having the same problem, didn't work when delivered to the customer. It head controls that looked like the controls on turbo air. I talked to tech support they said they couldn't...