Search:

Type: Posts; User: temp tech

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Thread: Tools

    by temp tech
    Replies
    36
    Views
    6,361

    All the above, I go nowhere without my leatherman...

    All the above, I go nowhere without my leatherman just sent a broken one to leathermn and they sent me a brand new model with sheath!!!
  2. Replies
    6
    Views
    1,003

    Well went on job and removed R22 pulled vac and...

    Well went on job and removed R22 pulled vac and charged system with MO99 and lo and behold it charged up and I had 30deg SH at condensor (no service port @ coil) all is well and pulling down. I dont...
  3. Replies
    1
    Views
    486

    cobining new and old acc. mod?

    I had an acc here as, markj or temp tech (my business name) just been to long to remember. Maby one of you mods could help out?
  4. Replies
    6
    Views
    1,003

    clean, no hm,as stated 50 deg

    clean, no hm,as stated 50 deg
  5. Replies
    6
    Views
    1,003

    8x8 walk in problem!

    I Have a 8x8 walk in with a bohn ADT0700F coil unit 1 hp parker valve condensor is a F3AH-A100-CAV-00 (R22) arived on job and the system was low of
    charge repaired leak at inlet of TXV and found...
  6. Replies
    19
    Views
    2,579

    charge @ completion unless it like a compressor...

    charge @ completion unless it like a compressor then I give a price for replacement of comp or larg repair and collect that,if they decline i collect my service charge. I have had to except a few...
  7. Replies
    43
    Views
    6,126

    Is the lo side flu between 25-30, if so likely...

    Is the lo side flu between 25-30, if so likely moisture in the system. Maby a low side leak and pulled some in on pump down (404 should set above a vac though), just a guess though. more info is...
  8. Replies
    2
    Views
    550

    Yea think it was markj maby but no biggie been 3...

    Yea think it was markj maby but no biggie been 3 or so years.
  9. Replies
    2
    Views
    550

    new or kind of to board

    Use to be on but couldnt remember the info. I back and im finding the info helpful already! Thanks. hopfully I can be of use.lol:cheers:

    Little info on me. I have 32 yr exp self imp for 20 of...
  10. Replies
    10
    Views
    3,048

    I want to find a good used 4-8ft break and...

    I want to find a good used 4-8ft break and pittsburgh and maby a notcher. where is a good place or does anyone have some used stuff?? Im in LA.

    [Edited by temp tech on 08-12-2005 at 12:49 PM]
  11. Replies
    15
    Views
    1,396

    America is diverse, these people that point out...

    America is diverse, these people that point out one race, religon or any other is very narrow minded.
  12. Replies
    194
    Views
    20,312

    A duct man that has no idea how to install a...

    A duct man that has no idea how to install a ducting system
    correctly.lol Having a 16" trunk line with 15-6" drops.
  13. Replies
    1
    Views
    993

    I need the # for the Co. that sales parts for the...

    I need the # for the Co. that sales parts for the old
    Whirlpool commercial Ice machines Modle # CECS2A. I use to have it but lost it and you cant serch it with having to look through all the...
  14. Replies
    6
    Views
    902

    If there NEW systems and are in need of service...

    If there NEW systems and are in need of service already, you may be better off doing the work your self.LOL
    All you need is some gauges and a few years of schooling
    in refrigeration.
  15. Replies
    10
    Views
    964

    I see the 80ft of lq line as a big problem but...

    I see the 80ft of lq line as a big problem but cant see it
    making the head ski like that.I would have ran 3/8 or 5/8 min. Sounds ODed and that could also be the deal with to
    small of a recver....
  16. Thread: evap temp

    by temp tech
    Replies
    55
    Views
    4,617

    Re: Ya know something?

    not to take sides but in the guys 3ed and last Q he is correct. But CD's post where very constructive and all the degrading/namecalling post are usless.
  17. Replies
    9
    Views
    917

    Richard, It is and Thanks! I have decided to go...

    Richard, It is and Thanks! I have decided to go with the
    crain got a quoat of $6K (close to my guess) and the Crain Co. looks to be verry good (less worrys on my part).All this for a bid.LOL

    ...
  18. Replies
    9
    Views
    917

    It's just one 25t gas pack and is doable with a...

    It's just one 25t gas pack and is doable with a crain and
    i was guessing at 5K and I'm kind of leaning twords the
    crain now but also like the sound of the ease of the chopper. I was thinking that...
  19. Replies
    9
    Views
    917

    I have a unit Im bidding on and its fairly tricky...

    I have a unit Im bidding on and its fairly tricky to get to with a crain and was wanting a few of yalls thoughts
    and exp. with using a chopper over a crain.
  20. Replies
    3
    Views
    717

    Thanks, I had guessed at 30.

    Thanks, I had guessed at 30.
  21. Replies
    3
    Views
    717

    I have a OLD carrier Model # M48DD028 seirl and...

    I have a OLD carrier Model # M48DD028 seirl and need to know the tonnage? it's 6000k BTU and Comp #1 3ph 230v 55rla
    #2 39.5 RLA.

    Thanks!
  22. Replies
    77
    Views
    46,637

    I didnt notice at first but your name is a little...

    I didnt notice at first but your name is a little different than mine, but very close. I was like, I dont remember wrighting any of this.LOL
  23. Replies
    14
    Views
    1,872

    With 30' you could refloor over the old one! What...

    With 30' you could refloor over the old one! What temp range are you trying to get the box down to?

    [Edited by temp tech on 06-04-2004 at 09:41 PM]
  24. Replies
    9
    Views
    1,490

    20 is good unless there isnt a defrost term ( a...

    20 is good unless there isnt a defrost term ( a line connected to X on the timer) I wouldnt go any lower than
    10 though.
  25. Replies
    82
    Views
    6,996

    Hey cockroach, don't bug me! LOL!!

    Hey cockroach, don't bug me!


    LOL!!
  26. Replies
    18
    Views
    1,638

    This sight is the best learnin aid ive found in a...

    This sight is the best learnin aid ive found in a long time.
    It makes me read and dig more for answers and furnishes
    good trade knowlage.

    Dave, Thoughs guys work here in my town, Ive seen them.
  27. Replies
    18
    Views
    1,638

    I've got one, somewhere. It was highly recomended...

    I've got one, somewhere. It was highly recomended to me also
    (years ago) I flipped through it once and that was it.
  28. Replies
    82
    Views
    6,996

    When I start using total NOD refrigerants im...

    When I start using total NOD refrigerants im going to charge
    a lot more more for it!!
  29. Replies
    82
    Views
    6,996

    9, Or pee in it!

    9, Or pee in it!
  30. Replies
    38
    Views
    23,476

    Oh the good ol days, umm ummm!!!! But that is the...

    Oh the good ol days, umm ummm!!!! But that is the worst
    job I have ever seen, THANK's lol I'll bet theres a few dead building inspectors on that roof!
  31. Replies
    18
    Views
    14,552

    Is that the 20oz traps or the 30oz? On the...

    Is that the 20oz traps or the 30oz?
    On the unit.lol you guy's are a riot!!
  32. Replies
    66
    Views
    26,482

    Just a little side note, If you cant install a...

    Just a little side note, If you cant install a Goodman system and sleep at night look into you skills! not Goodman.
    I dont install them anymore but the one's I have instaled have been very...
  33. Replies
    87
    Views
    32,524

    Talk about job security! That units to old to be...

    Talk about job security! That units to old to be a Carrier!