    Not sure what to do with it yet. A good concept,...

    Not sure what to do with it yet. A good concept, configured in browser, pretty easy to setup. Not sure what they are marketing it as. The cellular access seems better than the option Tridium has.
  2. Replies
    6
    Views
    365

    Testing one of their devices.

    Testing one of their devices.
  3. I know one is SCC (first type), second has points...

    I know one is SCC (first type), second has points for DA and regular setpoints.
  4. The setpoints are in the correct order, highest...

    The setpoints are in the correct order, highest is unocc cool, lowest is unocc heat. We made sure to bring the standby setpoints in too. There are no VAV boxes on the units. Are there any...
  5. Trane units with Lon interface not heating

    Good afternoon. Bringing some Trane units with Lon boards in them into Niagara AX. Trying to make sure that everything works, and have figured out everything but the heat. There are two different...
  6. Infocom Comm4 driver and Precedent units

    I'm trying to bring some Trane Precedent units into Niagara AX with the Infocom Comm4 driver and have a quick question about how to remotely get them to control. I can write to the occupied heating...
  7. Replies
    10
    Views
    1,697

    We do offer R2 certification, if you visit the...

    We do offer R2 certification, if you visit the site below, look for Environmental Systems. No classes are currently scheduled, but they are offered if enough interest is there.
    ...
  8. Modbus communication to Cutler Hammer Pow R Command

    Has anyone had any luck communicating with the Cutler Hammer BCB smart breakers? I'm not having much luck finding any info, and their tech support has just forwarded me literature that I had already...
  9. Replies
    13
    Views
    1,537

    Go to the Tridium website, and look under...

    Go to the Tridium website, and look under Training, Training Partners. There are at least two other sources, Cochrane in Michigan, and Environmental Systems in Wisconsin that do certification.
  10. Replies
    12
    Views
    836

    Johnson FX-40 question

    If I have a JCI system that currently has an NCM, and a NIE could I hang a FX-40 in the N2 trunk and have it log data from the other N2 devices without causing any problems with the NCM or NIE? ...
  11. Replies
    89
    Views
    12,442

    You can put a Tridium AX or R2 Jace in with a...

    You can put a Tridium AX or R2 Jace in with a Smart II driver. We do them all the time.
  12. Replies
    7
    Views
    1,002

    could you please e-mail it to me too? Thank...

    could you please e-mail it to me too?

    Thank you.
  13. Replies
    7
    Views
    1,111

    For the R2 Jaces, there is a possible option, but...

    For the R2 Jaces, there is a possible option, but hard to do sometimes:

    Tridium will re-license it for you (or a purchaser) to access if you can provide a letter from an officer of the end user...
  14. Replies
    8
    Views
    880

    It depends on the version you are running, but...

    It depends on the version you are running, but there was an updated Workbench jar file a while back, you should be able to find out the details on Niagara Central
  15. Replies
    2
    Views
    740

    The BACnet gateways for Carrier are pretty easy...

    The BACnet gateways for Carrier are pretty easy to use, but are fairly expensive (slightly north of $500 per unit). ALC makes the card, you can select modbus or BACnet ms/tp. It gives you 60...
  16. Replies
    5
    Views
    1,030

    There is one possible other option, use a R2 jace...

    There is one possible other option, use a R2 jace with the CCN driver, and export everything as BACnet into an AX jace.
  17. Andover Continuum integration question

    I'm bringing some Andover b3865/66 vav boxes into a R2 jace, I was able to learn the devices in, but no points were created. Is there a standard set of AI/AV/AO/BI/BV/BO points that I can manually...
  18. Replies
    20
    Views
    7,844

    Are you using the Modlink, or Intellicomfort?

    Are you using the Modlink, or Intellicomfort?
  19. Replies
    5
    Views
    1,795

    The NCRS migration server works pretty good with...

    The NCRS migration server works pretty good with R2. Depending on the number of controllers you are migrating, it can get pretty expensive. It is a pretty good integration, there are some...
  20. Replies
    1
    Views
    485

    if you use the element setup utility software,...

    if you use the element setup utility software, you can change the address to anything you want
  21. Replies
    17
    Views
    2,085

    You could reset the outdoor air level based on...

    You could reset the outdoor air level based on the PPM level, a simple programmable controller, with fan status (one binary input), CO2 level (one analog input), and a damper output (one analog...
  22. Replies
    6
    Views
    784

    Some of that depends on the system you are...

    Some of that depends on the system you are working with. Often, the Master will pass the token to the Slave, and process all data requests/read the data from the Slave, before passing it to the next...
  23. Replies
    4
    Views
    1,700

    It sounds like you've tried all of the different...

    It sounds like you've tried all of the different passwords, is there an IT person that can log in to the machine with a different account to see if there is something blocking you from logging in. ...
  24. Replies
    2
    Views
    812

    no major issues on the tridium side...lennox had...

    no major issues on the tridium side...lennox had some issues with their lon card on earlier revisions, those are supposed to be fixed now. the only thing that was out of the ordinary, when binding...
  25. Replies
    10
    Views
    1,089

    the ccn to lon gateway still resides on the ccn...

    the ccn to lon gateway still resides on the ccn bus, it will still communicate at 9600 baud. The ccn bus is still a polling service, the more devices you have, the longer it will take to complete a...