    navian water heater

    having a problem with a navian water heater... it will run fine and then all of a sudden it stops heating... home owner kinda thinks it sucks when they are taking a shower and it goes cold, It has...
  4. thank you Allen.... the why is what I expected:) ...

    thank you Allen.... the why is what I expected:) some of the things that Trane does leaves me shaking my head
  5. so could you tell me what happens when the...

    so could you tell me what happens when the calibrating solenoid fails... and just another question... why the hell does it need to be calibrated every minute
    also have you ever had one of these fails
  6. Replies
    8
    Views
    2,312

    Trane AHU blower shaft

    old AHU, went to do a bearing replacement, where bearing was shaft is worn badly. Called Trane, no available info for machine and no available parts. this shaft is 1 3/4" on ends and increases...
  7. Replies
    2
    Views
    421

    condensate pumps for mini spits

    i am looking for a pump for mini splits.... about a year ago the NEWS had a new pump that looked great hanging below the wall hung unit, it was small and like i said it was below, so it had a chance...
  8. Replies
    0
    Views
    503

    IHOP -AAON - Siemens controler

    Sorry in advance, but i am wondering if any of you have worked on an IHOP with AAON mau that has a siemens/steafa controller in it. i am having a problem with the controler not energizing the...
  9. Thread: Trane roof tops

    by nipper
    Replies
    10
    Views
    1,703

    it wasn't hard to see that you didn't have much...

    it wasn't hard to see that you didn't have much experience... like i tell my new ones, do the simple things first and don't call without having some info!!! know what you are asking

    there are a...
  10. Replies
    2
    Views
    486

    i am not sure that dumping the bypass is a good...

    i am not sure that dumping the bypass is a good idea but you can limit it by changing the static pressure and if i remember right this is a sort of calculation that trane uses and isn't straight...
  11. Replies
    7
    Views
    629

    you can spend lots of money doing this... or go...

    you can spend lots of money doing this... or go turn every other stat up one degree and let half of the unit take the load til it is near design. perimeter units would be able to control the load...
  12. Thread: Trane roof tops

    by nipper
    Replies
    10
    Views
    1,703

    a Trane roof top.... could you give less details...

    a Trane roof top.... could you give less details please
  13. Replies
    1
    Views
    423

    Master Air - Bonanza resturaunt??

    if anyone would have information on this Manufacture (Master Air). this unit that i am dealing with is an exhaust and fresh air in one. it has 1 motor that runs two wheels. i don't know if it was...
  14. Thread: lennox rtu

    by nipper
    Replies
    3
    Views
    793

    it is in the manual!

    it is in the manual!
  15. Thread: Intellipac

    by nipper
    Replies
    8
    Views
    1,436

    you need to know if it is the wire or the motor...

    you need to know if it is the wire or the motor that is cuasing you the problems. Take the wire off the vfd and run this up or let it run itself up and see if it is even the motor the wire or the...
  16. Replies
    9
    Views
    1,007

    foreget the pressure washer! sounds like you have...

    foreget the pressure washer! sounds like you have a different problem. how many fans? both running the correct way?
  17. Replies
    1
    Views
    708

    how much are you greasing those bearings?

    how much are you greasing those bearings?
  18. Replies
    10
    Views
    1,044

    depending on how big these units it may be better...

    depending on how big these units it may be better to replace them, but if the thing is good size then fix it, it you know you have the leaks spotted then you are talking a half a day or maybe a full...
  19. Replies
    4
    Views
    761

    great fonzy, that is a likely problem, the thing...

    great fonzy, that is a likely problem, the thing that i thought would be...is the stat wire shielded, could it be against any line voltage wires? but fonzy's is more consistant
  20. Thread: Some spiral

    by nipper
    Replies
    20
    Views
    2,911

    did you make the spiral look a like? the stuff on...

    did you make the spiral look a like? the stuff on the lennox, it was a great great idea! i am assuming that you ran it through the bead machine? is this correct?
  21. Replies
    11
    Views
    3,002

    looks like your water in and out are very close...

    looks like your water in and out are very close together, could slow that down and see if your temp to your compressor decreases, its like you have too much load on your evap in the heating mode and...
  22. Replies
    1
    Views
    775

    Most of my calls have be flame failure lately....

    Most of my calls have be flame failure lately. clean the sensor, check gas pressures off and running, belt tension, filters, burner offices, spark electrode, pilot flame. do you men have any tips....
  23. Replies
    10
    Views
    881

    milwalkee makes a skill saw that cuts metal and...

    milwalkee makes a skill saw that cuts metal and cuts it well. have wanted to try is on regular and spiral pipe but don't do much of it any more, i think this would be worth looking into
  24. Replies
    14
    Views
    2,365

    Check to make sure your 110 transformer is tapped...

    Check to make sure your 110 transformer is tapped correctly for the voltage that is supplied to the rtu. if you have a 208 supply, most likely from the factory, your transformer came tapped for 240,...
  25. Thread: unloader

    by nipper
    Replies
    9
    Views
    1,081

    thanks everyone, i had determined that it would...

    thanks everyone, i had determined that it would not load up because the solenoid was energized and i de-energized it and no difference in sound and amp draw. repeated this several times and no...