  1. The Buderus LT only comes with a well for the...

    The Buderus LT only comes with a well for the aquastat. The Logamatic comes with the 10K sensor.

    The TT Solo Trimax will work with either an aquastat (switch) or the sensor that comes with the...
  2. Unless your in the Arctic Circle I'd get the Solo...

    Unless your in the Arctic Circle I'd get the Solo 60 and keep the LT 160. The Solo 110 is probably too big. The LT 160 does my one full bath home just fine with a family of four.
  3. The TT boiler can be programmed to work with...

    The TT boiler can be programmed to work with either an aquastat (4006) or it's sensor for a domestic hot water demand.
  4. The TT boiler comes with the sensor for the...

    The TT boiler comes with the sensor for the domestic tank and it will fit into the well of the Buderus tank. When the Buderus sensor is used it gets clipped to the front of the tank on the LT's...
  5. The boiler should be sized for the heat loss of...

    The boiler should be sized for the heat loss of the house. The indirect should be sized for the hot water demand. If the amount of hot water with an LT 200 may be an issue, get a larger indirect. ...
  6. Nope, I put one in a crawlspace a few years ago...

    Nope, I put one in a crawlspace a few years ago for just that reason. In my own house I have space issues and the boiler is on top of the LT.
  7. Why are you getting an LT, they take up more room...

    Why are you getting an LT, they take up more room than the equivalent sized ST tank?
    It will couple just fine to the TT Solo 110.

    FYI I have an LT 160 in my own home, 8 years old now.
  8. Replies
    14
    Views
    421

    The Beckett Aquasmart has an adjustable circ...

    The Beckett Aquasmart has an adjustable circ delay on and off feature built into it.

    https://www.beckettcorp.com/products/aquasmart-7600-boiler-control/
  9. Replies
    43
    Views
    1,429

    I have my neighbors (who also happens to be my...

    I have my neighbors (who also happens to be my helper) set with a .5 nozzle in a Beckett NX can't remember the pump pressure but it's at least 140. The joke in the summer is my oil tank gauge is...
  10. Replies
    43
    Views
    1,429

    You won't be sorry with the B-3, your fuel...

    You won't be sorry with the B-3, your fuel consumption will go down. With regard to the heat loss, the B-3 is as small as you can go so as long as it's large enough, problem solved!
  11. Replies
    43
    Views
    1,429

    I'd wager that the B 10/3 would work. I put a B...

    I'd wager that the B 10/3 would work. I put a B 10/3 in a house about your size and it worked just fine last winter and the winter before that and the one before that. As someone stated earlier...
  12. Replies
    9
    Views
    332

    Around here the System 2000 is about $ more than...

    Around here the System 2000 is about $ more than the Buderus installed.
  13. Replies
    9
    Views
    332

    A lot of how a boiler sounds is based on the...

    A lot of how a boiler sounds is based on the chimney and whether or not it has an outside air kit on it. Some chimneys make the boiler sound louder than it really is.

    It's roughly 72" x 36", it's...
  14. Replies
    9
    Views
    332

    System 2000 is quietest oil fired boiler I have...

    System 2000 is quietest oil fired boiler I have heard. If noise is an issue it's the way to go. If you can tolerate a little sound then there are other options like a stackable system that Buderus...
  15. Replies
    12
    Views
    811

    It has a purge feature built into it so it...

    It has a purge feature built into it so it doesn't waste heat. It may have a little higher than optimal BTU output than some other boilers, but any boiler will probably be oversized for your home...
  16. Replies
    12
    Views
    811

    Someone needs to run a heatloss calc to find out...

    Someone needs to run a heatloss calc to find out what size would be appropriate for your residence.

    Based on your baseboard footage number it's probably 50,000 btu's or under (just a guess).
    ...
  17. Replies
    12
    Views
    811

    Cast iron we usually do Buderus, mod con it's a...

    Cast iron we usually do Buderus, mod con it's a Viessmann Vitodens.
  18. Replies
    12
    Views
    811

    The Biasi B 10 is a quality boiler, for what my...

    The Biasi B 10 is a quality boiler, for what my opinion may be worth.
  19. Replies
    12
    Views
    811

    Heatwise has been out of business for almost...

    Heatwise has been out of business for almost three years now, FYI
    We've been using the Beckett CG 4, really easy to set up.
  20. Replies
    4
    Views
    1,320

    Nice, somebody like cutting and threading pipe!

    Nice, somebody like cutting and threading pipe!
  21. 700 and some odd days on L.I. N.Y. without one...

    700 and some odd days on L.I. N.Y. without one above 90 degrees. Lets all say it together "Global Warming" AND this past winter had more HDD than anyone cares to remember and a few below design day.
  22. I had my C75 serviced a little over a year ago by...

    I had my C75 serviced a little over a year ago by UEI and it was $260. The oxygen sensor takes a dump every two years like clockwork, other than that it has worked great for seven years I've had it.
  23. Replies
    4
    Views
    511

    It's like the Wayne's World of fishing.

    It's like the Wayne's World of fishing.
  24. You answered the question in your post. ...

    You answered the question in your post. Corporations buy politicians (gov't) because of excessive government regulation (control). In a free market society I can buy from whoever I choose. And...
  25. Disposable income is what stimulates the economy,...

    Disposable income is what stimulates the economy, not necessities. People just surviving doesn't make for a healthy economy.
  26. How do you profess to increase disposable income?

    How do you profess to increase disposable income?
  27. That is in fact the problem with the country, the...

    That is in fact the problem with the country, the lack of rise in wages. I believe that is due to corporate taxes being too high, some of the highest in the world and the reason wages have stagnated...
  28. Excessive taxes are a bondage of sorts at least...

    Excessive taxes are a bondage of sorts at least for me they are.

    Galatians 5:1
  29. Replies
    17
    Views
    1,454

    You need to run the heat loss for each room to...

    You need to run the heat loss for each room to determine how much baseboard goes in each room. If you don't the rooms will be out of balance, some too warm, some too cool. You can adjust it a...
  30. http://www.slantfin.com/index.php/professionals/he...

    http://www.slantfin.com/index.php/professionals/heatloss
  31. I had Powersmith at my home, the presentation was...

    I had Powersmith at my home, the presentation was excellent. Powersmith and Green Audit USA basically do weatherization and insulation which we know further reduces the heat loss making a correctly...
  32. I did a heat loss on my home, what a waste of...

    I did a heat loss on my home, what a waste of time. 40,000 BTU's on a design day, I'm still looking for the right size boiler. Assuming the "average" sized home in Wantagh, you can't find a small...
  33. Green Audit USA does energy audits on Long Island

    Green Audit USA does energy audits on Long Island
  34. Replies
    16
    Views
    1,394

    What's the code for distance to the gas...

    What's the code for distance to the gas meter/regulator? Couldn't help it they're in the same photo.
  35. Replies
    16
    Views
    2,001

    I don't have any experience with the other units...

    I don't have any experience with the other units you mentioned.

    Baseboard doesn't always need to run at 180 degree temperatures to deliver enough heat to the house.
    If rooms are short on...
  36. Replies
    16
    Views
    2,001

    Equipment

    Contrary to popular belief high efficiency equipment works just fine with hydronic baseboard. Is it as efficient as other types of radiation, well anytime you can use lower water temperatures you...
  37. Replies
    16
    Views
    2,001

    ES-2 vs. Vitodens 100

    The ES-2 is a decent piece of equipment, it is an atmospheric cast iron gas boiler. It will require a chimney liner if it is vented into a masonry chimney. If you have a metal prefab chimney the...
  38. Replies
    63
    Views
    5,820

    I'm not a fan of those units.

    I'm not a fan of those units.
  39. Replies
    63
    Views
    5,820

    The fudge factor is already built into the heat...

    The fudge factor is already built into the heat loss software. So don't add anything.

    AND that is for a design day, how many hours do design days last? Not many.
    Almost all the time the boiler...
  40. Replies
    63
    Views
    5,820

    That is what is supposed to happen the boiler...

    That is what is supposed to happen the boiler should run 100% of the time on a design day assuming you have enough radiation to draw down the full output of the boiler. The reality of it is that...
  41. Replies
    63
    Views
    5,820

    Any good heating contractor knows to size the...

    Any good heating contractor knows to size the boiler to the heating load. And if necessary for the DHW demands oversize the indirect, the efficiency of such a system is superior as opposed to...
  42. Replies
    63
    Views
    5,820

    The boiler only has about 5 or 6 gallons of water...

    The boiler only has about 5 or 6 gallons of water in it compared to the 32 or so the water heater has, which will have a higher standby loss?
  43. Replies
    63
    Views
    5,820

    Indirect water heaters are more efficient that...

    Indirect water heaters are more efficient that direct fired water heaters, they have lower standby losses.
    As a general rule indirects are built better than your generic atmospheric gas water heater...
  44. Replies
    63
    Views
    5,820

    That's a central vacuum system on the left. The...

    That's a central vacuum system on the left. The storage tank is on the right.
  45. Replies
    63
    Views
    5,820

    Storage tank was existing and customer wouldn't...

    Storage tank was existing and customer wouldn't go for indirect.
  46. Replies
    63
    Views
    5,820

    Flat Plate HX

    The flat plate works as long as you have storage and the additional circulator as well.
    Not one of my better jobs, but it works.


    477461
  47. Replies
    16
    Views
    2,001

    Technical Heating Co. Mt. Sinai

    Technical Heating Co.
    Mt. Sinai
  48. Replies
    63
    Views
    5,820

    Replace It

    I'm with the Badger on this one, get rid of that dinosaur and upgrade to anything with natural gas.



    This one went to the scrap yard on Thursday.

    477341
  49. Replies
    75
    Views
    15,731

    Their, their :putergreet:

    Their, their :putergreet:
  50. Thread: Oil Boiler

    by R Mannino
    Replies
    6
    Views
    997

    Assuming the Buderus is installed with the...

    Assuming the Buderus is installed with the correct control strategy it will be more efficient than the other choices. Tankless coil boilers are subject to standby losses (staying hot all the time...
Results 1 to 50 of 322
Page 1 of 7 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech 365