Search:

Type: Posts; User: beardenbc

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    1,157

    Nah, I've tried both. ASCII is just the most...

    Nah, I've tried both. ASCII is just the most recent attempt after I had no success with RTU.
  2. Replies
    6
    Views
    1,157

    I was able to dig a blackbox IC1655A converter...

    I was able to dig a blackbox IC1655A converter out of a dank closet somewhere. Hopefully I can get this thing to work. We'll see how it goes.
  3. Replies
    6
    Views
    1,157

    GE modbus power meter EPM-4000!?!?!?

    Has anyone here ever successfully talked to a GE EPM 4000 power meter via modbus?

    I just got done integrating a nice big school with about 180 GSHP's, got the whole place comfortable and working...
  4. Replies
    2
    Views
    671

    Got it now. Thanks!

    Got it now. Thanks!
  5. Replies
    2
    Views
    671

    Bacnet 527 jar file

    I'm trying to get the 527 Bacnet jar file and it's associated bacnet.properties to fix a bug at one of our jobs. I've talked to tech support, but I'm having a hard time getting them to send the jar...
  6. Solution Found

    For those of you who may be interested, I finally found the solution, and it appears that there actually may indeed be a difference.

    In the beginning when I created the lexicons in the softjace, I...
  7. Jace 545 R2 stops polling bacnet objects after a few months

    Does anyone know what can cause a jace to stop polling a bacnet object after a few months?
    There is no visual indication of a problem except that the histories start holding the same value over and...
  8. Lexicons handled differently in embedded jaces?

    I'm programming a job for the School District. They have some requirements for status colors, i.e. overriden = yellow.

    I programmed the job on a softjace I had available while I waited for the...
  9. Replies
    2
    Views
    482

    Thanks. That's a lot better than the manual, I...

    Thanks. That's a lot better than the manual, I think I got it down now.
  10. Replies
    2
    Views
    482

    Niagara histories export questions

    So here's the situation.
    We're just getting into AX so this is actually our first AX job. Everything seems to be going smoothly so far. We have a site running an AX softjace that has a ton of bacnet...
  11. Whew, life saver. Thanks.

    Whew, life saver. Thanks.
  12. Simple (dumb) question about 2spd fan control for swamp coolers

    I was able to get myself 4 Champion 4001 DD's with 1/3 HP motors for $50 a piece today, planning on storing them in the garage and craigslisting them in June. I'd like to know something about the...
  13. Just watched the Monte Carlo burn from my office

    Fortunately, nobody was hurt as far as the news reports are saying. Word is there was some welding going on at the roof. I got a great view since it's only about a mile and a half away. Some of the...
  14. Replies
    0
    Views
    693

    Solid state soft jace.

    We just decided to upgrade the HDD on our AX softjace for a job with the school district to solid state. We had to take a hit on space (only 16G) because the things are so expensive for the SATA...
  15. Replies
    11
    Views
    805

    First boy. Also have a 4 year old daughter.

    First boy. Also have a 4 year old daughter.
  16. Replies
    11
    Views
    805

    And so, the wifey's ultrasound says...

    BOY!

    Booyah!
  17. Replies
    21
    Views
    3,266

    That's true. You could just write straight to 14,...

    That's true. You could just write straight to 14, only you'd have to wipe the code out of the controller alltogether to keep the internal code from writing to it too. The idea of the jace having 100%...
  18. Replies
    21
    Views
    3,266

    You got me kind of stumped there. Not sure. I'll...

    You got me kind of stumped there. Not sure. I'll keep an eye out for a solution, but that doesn't sound familiar.
    You might have to reboot, hit it 3 times with a green handled crescent wrench, and...
  19. Replies
    21
    Views
    3,266

    Sure, the jace can manually control the outputs,...

    Sure, the jace can manually control the outputs, assuming the points aren't locked out in the controller's ddc. In the end a jace can only write to points that a controller allows it to write to. If...
  20. Replies
    21
    Views
    3,266

    If the outputs on an Alerton Bactalk controller...

    If the outputs on an Alerton Bactalk controller are locked out, nothing can control those outputs except the controller's internal DDC.
  21. Replies
    21
    Views
    3,266

    Envision is the restricted software, but it's...

    Envision is the restricted software, but it's restricted only through hardware key, so if you have access to the old computer, you have access to it's hardware key too. Visuallogic is just a visio...
  22. Replies
    21
    Views
    3,266

    If a point is marked "out of service" this should...

    If a point is marked "out of service" this should only apply to AO's and BO's. To put them back into service, yes, you will need Envision. It can be done either from the bluescreen I mentioned...
  23. Replies
    21
    Views
    3,266

    Visio is a microsoft application used mostly for...

    Visio is a microsoft application used mostly for drafting, engineering, and various other graphic type applications. It's used in conjunction with Envision to give you visuallogic. Visuallogic is...
  24. Replies
    21
    Views
    3,266

    The best way to program the stuff is to get a...

    The best way to program the stuff is to get a copy of Alerton Envision for Bactalk and Microsoft Visio. That way you can use visuallogic. The interface for Visuallogic is graphic based. My avatar is...
  25. Replies
    1
    Views
    834

    I'm pretty sure that's just a 2.0 thing. You...

    I'm pretty sure that's just a 2.0 thing. You probably would have to upgrade Envision. Fortunately importing old jobs is a breeze.
  26. Replies
    1
    Views
    770

    Alerton plant DDC is pretty much always done from...

    Alerton plant DDC is pretty much always done from scratch because plants vary to much from job to job. Plants can be a bit difficult too. Timing problems can cause things to explode. I prefer the...
  27. Replies
    4
    Views
    1,700

    It will accept both. When you program the DDC in...

    It will accept both. When you program the DDC in visio, just doubleclick on the picture of the VLC, usually on the first page, then select Analog Inputs Setup, and select 10k or 3k thermistor on the...
  28. Replies
    37
    Views
    11,839

    The null modem is for BCM configuration only, not...

    The null modem is for BCM configuration only, not really used for communicating with the system. To configure the BCM though, go through hyperterminal, select com 1, then for the port settings use...
  29. Replies
    12
    Views
    2,603

    Email inbound to ya.

    Email inbound to ya.
  30. Replies
    1
    Views
    346

    disregard. Figured it out. I wish this stuff was...

    disregard. Figured it out. I wish this stuff was in the damn WPP Utilities manual. :mad:
  31. Replies
    1
    Views
    346

    LeftFrIE.html keeps disapearing

    Tridium question.
    Does anyone here know how to make the frame for the site tree stay?

    I can navigate using the tree all day with no problems, but as soon as I click a link inside the main view,...
  32. Replies
    83
    Views
    19,443

    Sure, I can get you some info. The FST is pretty...

    Sure, I can get you some info. The FST is pretty easy to use, basicly a battery powered global controller used at an bacnet over ethernet gateway. Everything configuration wise is done over serial...
  33. Replies
    83
    Views
    19,443

    Email's on the way.

    Email's on the way.
  34. Replies
    10
    Views
    2,091

    Thanks. I finally got it working this morning. I...

    Thanks. I finally got it working this morning. I snatched an html script from a job done by a guy who used to work here and edited it.
  35. Replies
    10
    Views
    2,091

    Bumpage... If anyone can explain the whole...

    Bumpage...

    If anyone can explain the whole concept of getting the Tree to display in a browser it would be much appreciated. I'm awful good at making buildings comfy, but I'm not a website...
  36. Replies
    2
    Views
    1,951

    Box Size (inches) = AV-250 Zero velocity cutoff...

    Box Size (inches) = AV-250
    Zero velocity cutoff = AV-251
    Calibration factor(K factor) = AV-252
    It's all in display number 82330000.
  37. Replies
    33
    Views
    6,057

    My perspective as someone who is new to Tridium:...

    My perspective as someone who is new to Tridium:
    Pros:
    1. It can talk to pretty much anything. You can have a system that has Trane LON Air handlers having their vaues reset based on the needs of...
  38. Replies
    10
    Views
    2,091

    Now I just have to figure out how to use this...

    Now I just have to figure out how to use this darn thing. I'm going through the manuals and whatnot. I've built the tree, but that's about it. I can't seem to get any information on how to actually...
  39. Replies
    10
    Views
    2,091

    thx Need to improve my google-fu.

    thx
    Need to improve my google-fu.
  40. Replies
    10
    Views
    2,091

    Tridium Site tree builder

    I've been googling this for a while, but can't come up with any results on where I can acquire this. It's the application that allows you to build a site tree on the web interface for Tridium. It's...
  41. Replies
    6
    Views
    829

    Likewise. I've helped you guys out before, and...

    Likewise. I've helped you guys out before, and I'll help you again, anytime.
    Once again, sorry for my earlier frustration.
  42. Replies
    6
    Views
    829

    Well so far the only guy who I've gotten...

    Well so far the only guy who I've gotten cooperation with is Lee, and he has been a big help, and I've helped him in return. The rest though, can't say. A certain individual there (starts with a "J",...
  43. Replies
    83
    Views
    19,443

    I was able to find this in the Programmer's...

    I was able to find this in the Programmer's guide:

    and on page 156 I found:

    I'm not sure if that's really much help. If you have something that you can use to interface with the mstp connector...
  44. Replies
    6
    Views
    829

    Thanks! Worked like a charm. I wonder why I...

    Thanks! Worked like a charm. I wonder why I wasn't able to find that in the manual.:\
  45. Replies
    6
    Views
    829

    Need help with Orcaview

    So I'm working this nightmare of a job with Clark county school district that has Trane, Delta, and Alerton all running off an R2 Jace...

    The client required a laptop with Envision, Tridium...
  46. Replies
    3
    Views
    884

    I've done it without any problems. No fancy...

    I've done it without any problems. No fancy settings involved. Perhaps you should try to alter the rdp settings if you have a slow connection. You can try setting it to 56k modem mode to save some...
  47. Replies
    83
    Views
    19,443

    The best way I've found to do that is through the...

    The best way I've found to do that is through the envision interface rather than through the microset. The microset way is kinda complicated, plus you have to ensure that the BV for service mode is...
  48. Replies
    83
    Views
    19,443

    Lemme know if you've got any questions. Alerton...

    Lemme know if you've got any questions. Alerton DDC is about 90% of my job so I can fill in anything that it doesn't cover.
  49. Replies
    83
    Views
    19,443

    I certainly can. File is on the way now.

    I certainly can. File is on the way now.
  50. Replies
    83
    Views
    19,443

    Honestly I'm not sure. I don't think you have to...

    Honestly I'm not sure. I don't think you have to be a dealer, but I could be mistaken. Let me know how it works out. If need be I can email it to you.