Search:

Type: Posts; User: wolfman32

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    2
    Views
    1,215

    I called Amana and it is no longer available so I...

    I called Amana and it is no longer available so I junked it out. Thanks anyway.
  2. Replies
    2
    Views
    1,215

    Amana Microwave

    I need a board for an Amana Microwave Mod. #CRC18T2 S/N. # 9703198913. I was told that it is no longer available. Thought someone may have collecting dust. Before it gets junked. Email is...
  3. Replies
    20
    Views
    4,594

    I have unpluged the HV transformer and turned it...

    I have unpluged the HV transformer and turned it and it will not blow a fuse. The HV trans. hums very loud. but nothing seems to be grounded. I have new spare parts and I have switched everything out...
  4. Replies
    20
    Views
    4,594

    Did that also I unpluged them 1 at a time then...

    Did that also I unpluged them 1 at a time then both at the same time.
    The samething.
  5. Replies
    20
    Views
    4,594

    I have checked everything to ground and nothing...

    I have checked everything to ground and nothing shows a ground. I understand about the high voltage. I treat all voltage as if it is deadly.
  6. Replies
    20
    Views
    4,594

    Tried door switch assembl thats not it. It can...

    Tried door switch assembl thats not it. It can get an amp draw reading it is pulling 82 amps. i called amana they didn't help any eaither thanks..
  7. Replies
    20
    Views
    4,594

    Thanks thats the only thing I've not checked.

    Thanks thats the only thing I've not checked.
  8. Replies
    20
    Views
    4,594

    Amana HDC18 Microwave

    I have one that is blowing fuses only when you try to cook. When you push a button to cook it will blow the fuse I have checked all I know. I am new to microwaves so any help would be GREAT!!
  9. Thread: New install

    by wolfman32
    Replies
    4
    Views
    1,602

    Well I had to go to it to check my self the init...

    Well I had to go to it to check my self the init is level but the curb is way off.
  10. Thread: New install

    by wolfman32
    Replies
    4
    Views
    1,602

    New install

    We got the bid on running gas line on a new building and another local contractor got the bid on installing the units and ducts.
    See anything wrong with this unit! There are 2 buildings I took this...
  11. Replies
    0
    Views
    624

    Coleman Gas Furnace

    I have a 90,000 BTU Coleman gas furnace for a mobile home new still in shrink wrap for $700.00 plus frieght if anyone is interested.
    Model # DGAAO90BDTA S/N # 030501370
  12. Thread: Tinknocker

    by wolfman32
    Replies
    5
    Views
    1,193

    Thanks its going to cost around 1000.00 to...

    Thanks its going to cost around 1000.00 to overhaul the flagler and the Tinknocker is 1895.00 thats why I was asking.The flagler has got so it kicks the metal out about halfway through. So I guess...
  13. Thread: Tinknocker

    by wolfman32
    Replies
    5
    Views
    1,193

    Tinknocker

    Anyone know if a Tinknocker pittsburg machine is anygood. We haqve a flagler that is on its last leg, and we are looking for a new one and came across a Tinknocker on Ebay.
  14. Replies
    2
    Views
    793

    Vent free fire place

    Went to check a fire place today the pilot light will light turn knob to hi fan switch to auto flames come on stays on for about 30 seconds then gas valve shuts off flames and pilot light go out....
  15. Replies
    13
    Views
    3,328

    I think I would have found more than...

    I think I would have found more than alcohol!!!!!! :D
  16. Replies
    13
    Views
    3,328

    It was real easy and it has a lot room inside I...

    It was real easy and it has a lot room inside I would get back inside to change the compreesor also.
  17. Replies
    13
    Views
    3,328

    Its an o6 model, and it was easyer to go from the...

    Its an o6 model, and it was easyer to go from the top then the side.
  18. Replies
    13
    Views
    3,328

    Really into my work

    This is what you call really getting into your work. My helper took this pic of me changing the reversing valve in a 14 seer Luxaire. Thank GOD for lots of room!!
  19. Replies
    84
    Views
    13,457

    You can go to a local flea market here and buy...

    You can go to a local flea market here and buy Goodman, Carrier,and Bryant equipment how they can sell carrier and Bryant I haven't figured out yet.
  20. Replies
    16
    Views
    4,504

    New condenser fan

    My boss went to check a freezer at a local store both condenser fans were bad and supply house had to order them,so he straped this window fan on it untill they came in. We went today to put them on...
  21. What are you wanting to change? Do you have the...

    What are you wanting to change? Do you have the instalattion instructions?
  22. Replies
    13
    Views
    4,719

    All metal is the way to go it may cost more and...

    All metal is the way to go it may cost more and take a littile longer to put in but in the long run it will be worth it. I have been to houses where the customer has to lay something ove the register...
  23. Replies
    45
    Views
    9,243

    Would be great if it would bend hard copper. We...

    Would be great if it would bend hard copper. We don't use linesets. We tried one bt yellow jacket and it broke the copper.
  24. Replies
    5
    Views
    1,070

    What do you mean by open and closed?

    What do you mean by open and closed?
  25. Replies
    3
    Views
    472

    YES definitely!! Thats what I did I work part...

    YES definitely!! Thats what I did I work part time while I went to school and it was the best thing I ever did!!!
  26. Replies
    15
    Views
    1,064

    She said that basically titleless is correct. She...

    She said that basically titleless is correct. She has been in this for 30+ years and when you left the drug store that released them of there responsibillity. When you sign those papers that says...
  27. Replies
    15
    Views
    1,064

    My mom does what do ya need to know.

    My mom does what do ya need to know.
  28. Thread: Electrical

    by wolfman32
    Replies
    5
    Views
    603

    No thats not what I mean. I'll explain in a...

    No thats not what I mean. I'll explain in a Littile more detail. My boss was telling us that years ago he was hooking up a air handler and when he turned the breaker on the whole naibourhood went...
  29. Thread: Electrical

    by wolfman32
    Replies
    5
    Views
    603

    Ok guys I was wondering if anyone could explain...

    Ok guys I was wondering if anyone could explain how bumping phases is done. I heard someone talking the other day about it, and I was wondering how it happens I have a theory but not sure if it is...
  30. Replies
    395
    Views
    30,477

    wolfman32: Wendell Smith - Barbourville, KY...

    wolfman32: Wendell Smith - Barbourville, KY Installer/Service Tech
  31. Replies
    5
    Views
    743

    Well they changed the test after 08/31. You can...

    Well they changed the test after 08/31. You can call the KY Office of Housing, Buildings, and Construction (502) 573-0360 and they can tell what you need. If it was still the old test I could help...
  32. Thread: Tempstar

    by wolfman32
    Replies
    6
    Views
    1,574

    Don't know which one came first just saw it from...

    Don't know which one came first just saw it from across the street and thought you guys would have fun with it.
  33. Thread: Tempstar

    by wolfman32
    Replies
    6
    Views
    1,574

    How would you like to change the condenser motor...

    How would you like to change the condenser motor on this unit! http://www.imagewiz.net/usr/hvac1/24085_100_0733.jpg
    We are working across the street from this and thought boy I don't want to work on...
  34. Replies
    74
    Views
    3,867

    Mine would be Jo Jo 25!

    Mine would be Jo Jo 25!
  35. Thread: Deer ?

    by wolfman32
    Replies
    44
    Views
    2,683

    Good Luck guys didn't get to hunt last year we...

    Good Luck guys didn't get to hunt last year we were way to busy and its not looking good so far this year.
  36. Replies
    14
    Views
    1,620

    Well I use a superheat calculation kit which is...

    Well I use a superheat calculation kit which is just a shrader valve removal tool that when you pull the valve out there is a thermometer that you put in the place of the shrader valve to get you...
  37. Replies
    25
    Views
    1,961

    I have a DL250 and so far so good I'v had it...

    I have a DL250 and so far so good I'v had it about a year now now problams. The way I look at it is, if it aint broke don't fix it and my UEI sure aint broke. When and if it does then I'll go from...
  38. Replies
    16
    Views
    1,530

    I'v told some friends in the trade and my boss...

    I'v told some friends in the trade and my boss they have all checked it out but don't think they come here much.
  39. Replies
    13
    Views
    2,844

    Went to a lawers office on a no cool call he has...

    Went to a lawers office on a no cool call he has a westinghouse still running great. The call was on a coleman in another office that he rents out.
  40. Replies
    5
    Views
    720

    Yes the foil tape will hold up.

    Yes the foil tape will hold up.
  41. Replies
    2
    Views
    422

    3

    3
  42. Thread: divorce

    by wolfman32
    Replies
    2
    Views
    1,120

    Wish I had divorced my first wife that way!!!! HA...

    Wish I had divorced my first wife that way!!!! HA HA HA
  43. Thread: pressures

    by wolfman32
    Replies
    6
    Views
    1,666

    On a 75 degree day the high side shuold be around...

    On a 75 degree day the high side shuold be around 210 psi.
    The low side should be around 68-70 psi. You need to get a temperature/pressure chart, and then take the ambiet temp. and add 30 degrees to...
  44. Replies
    16
    Views
    1,279

    My boss got me good. I had went on a call on...

    My boss got me good. I had went on a call on Monday there was a blown fuse I replaced and check everything out couldn't find a problam. There was bad storms the night before so thought it was a power...
  45. Replies
    4
    Views
    2,437

    I agree with cde72 they would be more trouble...

    I agree with cde72 they would be more trouble then they are worth!!
  46. Replies
    30
    Views
    2,189

    How about HEE HAW!

    How about HEE HAW!
  47. Replies
    6
    Views
    3,827

    We use hard pipe and we tape each connection with...

    We use hard pipe and we tape each connection with foil tape and insulate everything but the return in a crawlspace, but we do tape all connections of the return and we also use duct sealer on the...
  48. Replies
    5
    Views
    568

    Thanks coolwhip!! I'm haven't been in this feild...

    Thanks coolwhip!! I'm haven't been in this feild all that long getting ready for my last semester of school and I"m woking for a guy that is really good and learning a lot from him and school and...
  49. Replies
    5
    Views
    568

    Yes had good voltage and it was hot enough to fry...

    Yes had good voltage and it was hot enough to fry eggs on it.
  50. Replies
    5
    Views
    568

    Went to check a Janitrol gas furnace in a drugs...

    Went to check a Janitrol gas furnace in a drugs store yesterday, there was a loud huming sound coming from the return grill it would stop after just a few seconds then a few minutes later it would do...