Search:

Type: Posts; User: jonny in La

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    4
    Views
    1,739

    Source Refrigeration.

    How are they to work for.
  2. Replies
    0
    Views
    521

    supermarket work

    supermarket tech looking to stay in ohio anybody got any leads
  3. Replies
    17
    Views
    1,860

    30 an hour after a few years all I can say is you...

    30 an hour after a few years all I can say is you better have another job lined up, to get to that wage you need years of experience but if you stick with it apply yourself dont undercut yourself...
  4. Thread: Deem

    by jonny in La
    Replies
    5
    Views
    1,170

    at least theres nothing negative thanks Berger

    at least theres nothing negative thanks Berger
  5. Thread: Deem

    by jonny in La
    Replies
    5
    Views
    1,170

    Deem

    Anybody work for this company before theyre out of Indianapolis Indianna
  6. Replies
    8
    Views
    1,691

    behold ye ole cornholenelius

    behold ye ole cornholenelius
  7. Replies
    28
    Views
    2,108

    check your superheat and make sure that the drain...

    check your superheat and make sure that the drain to all evaps are trapped.
  8. the reason why you do that is its better in a...

    the reason why you do that is its better in a warm enviroment and it'll help keep a better product temp and you wont need a defrost timer
  9. temperature control

    go and get an adjustable stat ranco or penn it should have a pigtail for the sensing bulb stick it in the coil set your c.o at 18-20 your ci at 40 degrees if the unit runs right and is charged right...
  10. reach in on cook line

    I learned that if you sit back and watch the line when its busy you'll learn something. Heres a clue are the cooks leaving the doors or drawers cracked think about it for a minute Ill give an answer...
  11. Replies
    27
    Views
    2,754

    you could go into automation and probably trane...

    you could go into automation and probably trane carrier mcquay etc... you'd be in the field and working with hvac..... with your electrical degree and allllllll:D:D:D:D:D:D:D
  12. Replies
    5
    Views
    1,061

    when i say variable its actually a digital you...

    when i say variable its actually a digital you know the new copeland any how its getting worked out thanks guyzzzz.:D:D:D
  13. Replies
    30
    Views
    2,722

    you can always spot managers that have no...

    you can always spot managers that have no experience either dealing with techs or customers its a skill just like being a tech takes a lot of time to develope.Also bet you theyre the kind that talks...
  14. Replies
    5
    Views
    1,061

    hill phoenix rack

    service information packet on hill phoenix rack split header with variable capacity copeland on medium temp side any help would be appreciated.
  15. Replies
    11
    Views
    1,824

    talk to your parts house and ask for the...

    talk to your parts house and ask for the performance curve or you do the ol compressor efficiency if you can find out how many gpms its pumping.
  16. Replies
    6
    Views
    1,179

    if there was such a shortage how come they werent...

    if there was such a shortage how come they werent recruiting when it was slow.
  17. Replies
    37
    Views
    2,847

    i use to work with a guy who was a contractor he...

    i use to work with a guy who was a contractor he moved to La and they have him wrapped up sorry to say it but thats where all the jobs are at due to oil exploration if your interested in going there...
  18. Replies
    1
    Views
    704

    put in for a position as a install helper...

    put in for a position as a install helper guaranteed to learn it ground up the best way in my book your not going to make tech pay but its a start.
  19. Replies
    10
    Views
    717

    hey cracker can I get it to new target store has...

    hey cracker can I get it to new target store has em and I dont want to stumble around in the dark
  20. Replies
    7
    Views
    844

    if its in a steel plant believe you got holes in...

    if its in a steel plant believe you got holes in your flexible hose go get a D TEK you'll be glad you did is it running 124.
  21. Replies
    4
    Views
    1,841

    yes I did thanks boys!!!!!

    yes I did thanks boys!!!!!
  22. Replies
    4
    Views
    1,841

    enthalpy chart

    where can I get an enthalpy chart for air any help would be greatly appreciated.
  23. Replies
    28
    Views
    2,273

    i'd say fine if he's gonna give you approximately...

    i'd say fine if he's gonna give you approximately 18% of the job this is what air now companies do if he's gonna pay you less i'd say no way and at that % you can easily make fifty and up
  24. Thread: Headmaster

    by jonny in La
    Replies
    10
    Views
    1,131

    that was in Ohio or you dont consider that North

    that was in Ohio or you dont consider that North
  25. Thread: Headmaster

    by jonny in La
    Replies
    10
    Views
    1,131

    rule of thumb I always use on smaller systems...

    rule of thumb I always use on smaller systems used in restauraunts of course not supermarkets add 1lb additionally past clear sightglass and you'll be charged correctly for the operation of a wic and...
  26. Replies
    13
    Views
    2,166

    they use to use r12 in cospolich so it does work...

    they use to use r12 in cospolich so it does work but it wont get your product generally below 0 mp66 i mean due to its saturation and glide total charge will be about 85% of nameplate and no 134 ...
  27. Replies
    11
    Views
    2,635

    the temps are almost exactly the same you should...

    the temps are almost exactly the same you should be fine if not change the txv with a element thats designed for 404. Heres a hint look at a multi element purple orange and green what do you think...
  28. Replies
    32
    Views
    2,405

    pssssst pinch off tool!!!!!!!!:D:D:D ps never...

    pssssst pinch off tool!!!!!!!!:D:D:D ps never pump a unit into a vacuum to 0 only if it creeps up you may have to pump it down a few times due to the refrigerant in the oil boiling off.
  29. Replies
    15
    Views
    1,623

    doenst know the tonnage but he does know the...

    doenst know the tonnage but he does know the barrel and tubes are ok:eek::eek::eek:
  30. Replies
    40
    Views
    4,939

    are you an in house guy or a contractor if your...

    are you an in house guy or a contractor if your in house call a company that can fix it if your a contractor get somebody ummmmm your boss that can fix the damnnn thing
  31. Thread: Esr Woes

    by jonny in La
    Replies
    33
    Views
    2,321

    have you tried micing the id to see if the body...

    have you tried micing the id to see if the body is out of round try this first sounds like its hanging up the plunger and body could have 2 different expansion rates based upon the makeup of the...
  32. Replies
    32
    Views
    2,405

    no 1 call manufacturer make sure the right...

    no 1 call manufacturer make sure the right compressor is in it hp wise now you'll need to pump the compressor down to check the valves if both those check out which they probably wont take some gas...
  33. Replies
    7
    Views
    1,348

    cfm equation

    would anybody know the cfm equation used for furnaces . Been a while and I need to fiqure out a problem.
  34. try washer stromm they do a lotta custom work

    try washer stromm they do a lotta custom work
  35. Replies
    9
    Views
    1,312

    ohms law;

    ohms law;
  36. Thread: Tyler s/c

    by jonny in La
    Replies
    11
    Views
    1,453

    good to now you got it figured out

    good to now you got it figured out
  37. Replies
    16
    Views
    3,660

    try case parts, refrigeration wholesale and fmp

    try case parts, refrigeration wholesale and fmp
  38. Replies
    17
    Views
    1,646

    a8 and a9 valve if i remember correctly are what...

    a8 and a9 valve if i remember correctly are what we call a holdback or flooding valve for the condensor either for additional subcooling and condensor flooding and a receiver pressure regulating...
  39. try Air Temp they do a lot of heavy commercial...

    try Air Temp they do a lot of heavy commercial and industrial good guys especially John sole and Ron.
  40. Replies
    15
    Views
    1,842

    I would do like kiwi said then use a vacuum pump...

    I would do like kiwi said then use a vacuum pump not the compressor to pull it into a vacuum and pull the oil in thru the the crankcase connection for the oil failure.
  41. Replies
    1
    Views
    551

    know that when we were setting pressure controls...

    know that when we were setting pressure controls for a washerstrom ci @ 40degrees sst and co @ 28 degrees you may have to go more or less but start there.
  42. Thread: Tyler s/c

    by jonny in La
    Replies
    11
    Views
    1,453

    your suctions to high did you perform a pumpdown...

    your suctions to high did you perform a pumpdown your high side valves are probably ok your low side valves are not typically you'll see about a 55-60 psi when its at temp with 404 had a similar...
  43. have him check the hertz you got stator burning...

    have him check the hertz you got stator burning but no scoring of the journals and no cracked or busted valves your most likely going to find an electrical problem as statts stated use a phase...
  44. Replies
    3
    Views
    581

    or go to copelands sight and see for yourself

    or go to copelands sight and see for yourself
  45. Replies
    6
    Views
    919

    check your water coaxial for leaks meaning...

    check your water coaxial for leaks meaning weather or not water is leaking from the tube to tube also is this a trane unit with their brand of Scrolls they were know to have problems if it was me i...
  46. Thread: mac77

    by jonny in La
    Replies
    3
    Views
    499

    dude whats your sales approach I can get more...

    dude whats your sales approach I can get more work than I can handle just dont have enough techs to handle it and thats me cold calling and meeting 1st tier level service reps. email is in my profile...
  47. Replies
    17
    Views
    1,480

    mp39 is a blend it has glide should only be...

    mp39 is a blend it has glide should only be charged to 85% check your headmaster by getting your spraypot fill it with ice 1st then water spray the condensor the headmaster should bypass the liqline...
  48. Thread: cap tubes

    by jonny in La
    Replies
    0
    Views
    439

    cap tubes

    alright boys gotta piece of kairak equipment static plate well cooler with a fan and a regular ol forced air dx coil underneath problem is the dx has an
    .052 cap tube coil is rated at 600 btus...
  49. Replies
    37
    Views
    6,239

    the reason why the liq line and suction line are...

    the reason why the liq line and suction line are brazed togethter i take it at the evap is to further subcool the liquid before it enters the expansion valve just a rule of thumb the warmer the...
  50. Thread: Pro Air

    by jonny in La
    Replies
    3
    Views
    684

    sure didnt dude thought you gave him my resume...

    sure didnt dude thought you gave him my resume anyways went to Pro Air to interview they wanted to hire me they work on a lot of big chillers told them i would have to think about it anyways told my...
Results 1 to 50 of 88
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event