  1. Thread: Radon

    by jackpiner
    Replies
    19
    Views
    4,513

    Safety siron pro 3 has an alarm but no dry...

    Safety siron pro 3 has an alarm but no dry contacts. contact them maybe they have a commercial version available.
  2. Replies
    5
    Views
    1,244

    We must be dealing with the same supply house!...

    We must be dealing with the same supply house!
    There are 2 different exv coils one has a red plug the other has a white plug.
    They are both the same except for the color of the plug. Fujitsu in NJ...
  3. Replies
    5
    Views
    1,244

    Check the EXV, make shure it's clipped to the...

    Check the EXV, make shure it's clipped to the tubing.
    When power is turned off then on, you should hear it clicking. If not look at the manual for checking resistance.
  4. Replies
    1
    Views
    594

    Opinions on refrigeration leak sealer.

    I have never used any of the leak sealer products.
    Do they work? Any side effects? Is one better than the other?
    thanks for your opinions.
  5. Replies
    15
    Views
    2,423

    I have installed quite a few of these systems...

    I have installed quite a few of these systems with no problems. Sounds like a wiring issue to me, trace the wires from each air handler to their proper connections on the condensing unit.
  6. I agree this is a common problem on the York...

    I agree this is a common problem on the York RTU's. Sometimes I have to use a piece of wire to clean them out because air, or N2 pressure won't dislodge the spider eggsacks.
  7. Thread: Radon

    by jackpiner
    Replies
    19
    Views
    4,513

    Radon levels in a home change continuously...

    Radon levels in a home change continuously according to wet or dry soil or freezing ground conditions, barometric pressure, indoor fan use, etc.
    I have Radon in my home and have been monitoring it...
  8. Replies
    12
    Views
    3,093

    Tiny Spiders like to build webs in the tubes and...

    Tiny Spiders like to build webs in the tubes and sometimes in the orifice, look real close and you may find 1.
  9. Replies
    24
    Views
    3,295

    The simple fix is to add another duct run to the...

    The simple fix is to add another duct run to the area to increase the cfm available to the room.
    Do a manual J on the room first to find out what is required.
  10. Replies
    28
    Views
    3,278

    Oh crap the doctor's going to charge me to much!...

    Oh crap the doctor's going to charge me to much!
    I'll just buy a scalpel and sutures and and do it myself.
  11. Replies
    28
    Views
    3,278

    The problem is there is always someone that will...

    The problem is there is always someone that will agree to do the start up.
  12. Replies
    8
    Views
    666

    In my experience apartments, & condo's are...

    In my experience apartments, & condo's are usually flexed, and there are always low flow registers because of improper design and installation. Don't worry about the one register, unless you intend...
  13. Replies
    13
    Views
    1,449

    Clean up as you are planning, with the flush, use...

    Clean up as you are planning, with the flush, use a canister type suction filter replacing the core daily. Then plan on replacing the compressor a second time, the first replacement will clean up the...
  14. Do a search for heatcalc.xls 1.09 for operating...

    Do a search for heatcalc.xls 1.09 for operating costs, and look at Daikin Altherma.
  15. I agree. Or you can have the rule of thumb...

    I agree.
    Or you can have the rule of thumb calculation for free.
  16. Replies
    48
    Views
    2,866

    Start out as a helper or apprentice. Keep looking...

    Start out as a helper or apprentice. Keep looking you will find a job.
  17. Replies
    9
    Views
    3,108

    Why not go with a solar thermal system as your...

    Why not go with a solar thermal system as your buffer and use about 1 KW of electric a day for the pumps.
  18. Replies
    875
    Views
    104,086

    My problem is with the wells. I have been...

    My problem is with the wells. I have been installing & servicing heat pumps for over 30 years.
    I don't know anything about geology or well drilling so I would have to sub that portion of the job...
  19. Replies
    875
    Views
    104,086

    Ok thanks that's what I wanted to know. The...

    Ok thanks that's what I wanted to know. The panels are much more efficient at colder water temps but none of the manufacturers rate them at those cooler temps. The delta T of 30 degrees tells it all....
  20. Replies
    875
    Views
    104,086

    Very Interesting. What is the capacity of the...

    Very Interesting.
    What is the capacity of the solar thermal system that you have connected, and are you using evacuated tube or flat plates.
  21. Replies
    4
    Views
    1,179

    Energy saving measures are still your best...

    Energy saving measures are still your best investment on a 1983 house.
    You probably have R-19 walls and R-30 ceilings, the lower you can get your heatloss and gains the smaller the GEO system will...
  22. Replies
    4
    Views
    1,179

    Depends on your climate and existing home...

    Depends on your climate and existing home construction.
    Geo thermal works well in very tight homes. Older homes require additional insulation and other energy saving measures.
    The tighter the...
  23. Replies
    24
    Views
    1,921

    When you buy a computer windows comes installed...

    When you buy a computer windows comes installed and anyone can use that computer, the software is included in the price of the computer. As is the Tracker software installed in the Varitrac. Why...
  24. Replies
    24
    Views
    1,921

    I agree with you here. I am in the same boat as...

    I agree with you here. I am in the same boat as you. I am working on a tracker system and can get no support from Trane. They want me to bring in the Trane Factory Tech. Right I'm supposed to turn...
  25. Replies
    10
    Views
    552

    I use a Testo 330. The only electronic that I...

    I use a Testo 330. The only electronic that I have ever used.
  26. Thread: White Ice

    by jackpiner
    Replies
    49
    Views
    2,522

    White ice usually means air bubbles in the water....

    White ice usually means air bubbles in the water. Check your water level in the sump.
    Snowy or fluffy ice= running out of water before the end of cycle.
  27. Replies
    3
    Views
    1,601

    I have been using Fantech -Nice units. Get the...

    I have been using Fantech -Nice units. Get the electronic controller, EDF5
    http://www.fantech.net/
  28. Your climate is perfectly suited for a heat pump...

    Your climate is perfectly suited for a heat pump system. Plus you are in California which has generous incentives for Solar PV. You could in the future add a PV system to your house which would...
  29. Replies
    9
    Views
    1,032

    fan cycling control will work, but never as well...

    fan cycling control will work, but never as well as the headmaster. The head master will keep the head pressure constant. with the fan cycling control the head pressure will be all over the place...
  30. Replies
    17
    Views
    2,446

    Install an 1 HRV for your bathrooms such as a...

    Install an 1 HRV for your bathrooms such as a Fantec, it is available with a controller that can cycle the HRV. http://www.fantech.net/hrv_erv.htm
    Then when you run your kitchen hood open a window!
  31. Replies
    4
    Views
    1,555

    You will need your return lined with ductliner,...

    You will need your return lined with ductliner, that should help some.
  32. Replies
    10
    Views
    2,004

    The answers to your questions: 1- yes Honeywell...

    The answers to your questions:
    1- yes Honeywell makes a outdoor temperature compensated humidistat-dehumid controller. Or change T stat to an 8000 pro with humidification feature & outdoor sensor....
  33. Replies
    11
    Views
    987

    Well if it's driven by a 60 HP motor a good guess...

    Well if it's driven by a 60 HP motor a good guess would be that it's in the area of a 60 ton capacity unit or 720,000 btu.
  34. Replies
    12
    Views
    1,262

    check for a white powder residue on your fuse...

    check for a white powder residue on your fuse block or contactors. This will indicate if the component insulation is breaking down & shorting to ground or across legs. Usually during very humid or...
  35. Replies
    16
    Views
    1,495

    Try to pump it down- if it doesn't then you have...

    Try to pump it down- if it doesn't then you have your answer, bad valves.
  36. Replies
    39
    Views
    2,433

    Dewalt 12V impact driver, & Dewalt 1/2" 18v...

    Dewalt 12V impact driver, & Dewalt 1/2" 18v hammer drill.I use the impact driver daily because it's small & light and has plenty of power. The hammer drill is saved for heavy duty jobs.
  37. Replies
    9
    Views
    1,377

    I have the Tiff electronic sightglass and I use...

    I have the Tiff electronic sightglass and I use it occasionally, on old systems good for letting you know if you have solid liquid column at the metering device, or a fully flooded evap. It will get...
  38. Replies
    4
    Views
    1,295

    Keep it simple, buy your test kit at the supply...

    Keep it simple, buy your test kit at the supply house they have small plastic barrels with litmus paper in the center, just crack your discharge or liquid line for a second blowing refrigerant and...
  39. Replies
    12
    Views
    1,346

    I use a GALLO gun, fits in my toolbag and uses...

    I use a GALLO gun, fits in my toolbag and uses small CO2 cartridges used in BB guns that I buy at my local sporting goods store. They also make another model that uses a slightly larger CO2...
  40. Replies
    9
    Views
    1,043

    1/2" x 1 1/8" is what you need for the long runs...

    1/2" x 1 1/8" is what you need for the long runs if your using R-22. 3/8 is only good for 50' on a 5 ton unit. I don't have a 410A chart yet.:)
  41. [QUOTE=pines;1557823]What I want to know is:Is...

    [QUOTE=pines;1557823]What I want to know is:Is the cooling efficiency basically the same on both units?



    Yes
  42. Replies
    5
    Views
    972

    Those old compressors were well made, & easy to...

    Those old compressors were well made, & easy to rebuild on site, but they used a hell of a lot of iron to make those dinasaurs.
    If you take it home and you can get 3 phase to it they make...
  43. Replies
    5
    Views
    972

    If you want another oldie I have a jobsite with...

    If you want another oldie I have a jobsite with an old Typhoon (Schnakie Grosso) 30 HP vintage 1948. Just waiting for someone to remove it from the mechanical room. :D
  44. Replies
    0
    Views
    1,112

    Snyder General/Microtech monitor software

    Does anyone have a copy of the Microtech open protocol monitor software for a Mcquay/ Snyder General unit ventilator. I have been trying to get a copy from my dealer for a month with no luck. It's...
  45. Replies
    7
    Views
    1,107

    All mini split heat pumps are not intended to be...

    All mini split heat pumps are not intended to be used as a primary heat source as they have no electric resistance heaters installed. Check out the web sites they all state this clearly....
  46. My guages also have a vent or fill valve on top,...

    My guages also have a vent or fill valve on top, and they can be a problem. I have a piece of ducttape on mine so they don't get lost.
    They are still better than the standard guages and a hell of a...
  47. Buy a set of the glycerin filled guages only and...

    Buy a set of the glycerin filled guages only and put them on your old manifold, they don't need to be recalibrated as often & they have glass lenses.
  48. Replies
    6
    Views
    2,155

    You need to get someone qualified to work on this...

    You need to get someone qualified to work on this chiller. Sounds like no call for cooling at this time
    Solenoid valve is leaking by slightly that why liguid line is sweating.
    RR is reset relay...
  49. Replies
    31
    Views
    12,149

    The Bryant 2 stage furnace will use less gas and...

    The Bryant 2 stage furnace will use less gas and cycle less often when operating on low fire.
  50. Replies
    30
    Views
    5,594

    Excuse me, I'll me right back I have to get a...

    Excuse me, I'll me right back I have to get a part.