New Kid
Here are some suggestions. Do "good, honest work" install/replace/repair if it is needed. Word will get around slowly if you are fair. Word will travel like a wild fire if you are sloppy,...
-
02-18-2006, 08:13 AM
Thread: Direct Venting for 92% Efficient Furnace
by theblade- Replies
- 10
- Views
- 1,150
Ask to see the manufacturers installation...
Ask to see the manufacturers installation instructions. all the limitations, requirements will be in there. I know for a fact on the Trane TUY series, you can have up to 200 ft. of pipe under...
-
09-02-2005, 07:32 PM
Thread: Brazing filter dryer
by theblade- Replies
- 9
- Views
- 1,305
Just a reminder. If you are removing an old dry,...
Just a reminder. If you are removing an old dry, don't use a torch to remove the dryer. Cut the dryer out with a tubing cutter. any moisture or other contanments trapped in the dryer, will bre...
-
05-16-2005, 09:23 PM
Thread: Need coil replacement advice....
by theblade- Replies
- 20
- Views
- 1,800
One thing to keep in mind, in Jan. 2006 min. seer...
One thing to keep in mind, in Jan. 2006 min. seer to be manufactured is 13 seer. You may have a real problem trying to match an r-22 coil installed now, with what is available in r-22, two or...
-
04-24-2005, 02:20 PM
- Replies
- 7
- Views
- 1,614
Very important that you find a Rheem Trained...
Very important that you find a Rheem Trained Tech. quick. Only some one trained and experienced in gas furnaces can evaluate just how dangerious your situtation is. Don't delay. It might be just...
-
03-29-2005, 09:23 PM
Thread: Info. on no name equipment.
by theblade- Replies
- 1
- Views
- 629
No name, city, address, on air handler. Model #...
No name, city, address, on air handler. Model # FMB10 36+X3 000 --- coil # FMBXX 36+X3. Need to know if coil will work with heat pump? Has txv, no bypass check valve. Some txv's have by pass ...
-
03-09-2005, 06:55 AM
Thread: solenoid valve
by theblade- Replies
- 8
- Views
- 874
Magic Chef, (Armstrong) did this in mid 1980's. ...
Magic Chef, (Armstrong) did this in mid 1980's. 8 seer
a/c units. Could add selenoid valve near evaporator coil,
paralell with low voltage to condenser. When condenser stopped at end of... -
02-17-2005, 07:25 PM
Thread: R410A? Pros and Cons please
by theblade- Replies
- 26
- Views
- 6,096
For the time being, it looks as it will be "the"...
For the time being, it looks as it will be "the" new refrigerant. Will some one develope something later that is better/less costly, safer, who knows? Only time will tell. Properly...
-
02-15-2005, 08:58 PM
Thread: labor rate
by theblade- Replies
- 12
- Views
- 1,673
If you are working for some one else, it will be...
If you are working for some one else, it will be what you are worth to them. How tight the labor market is, how qualified you are, and how you present your self to your employer. There is really...
-
02-15-2005, 08:25 PM
Thread: NEVER SEEN THIS BEFORE!!
by theblade- Replies
- 3
- Views
- 983
Worked on one or two, called "insider" seems...
Worked on one or two, called "insider" seems like the one's I worked on were made by a defferent co. Been couple of years. Lot of noise & viberation for inside a home. I think the one's I worked...