  1. The conventional estimates I received would only...

    The conventional estimates I received would only utilize one return, at the top of the stairs on the second floor, same as the HV system. That is why I am concerned about performance. I don't think...
  2. I think the HV guys would say that operating...

    I think the HV guys would say that operating costs would be about the same, since the unit doesn't have to work as hard to reach an even temp, but not sure I believe it. I would really be interested...
  3. Operating cost of High velocity vs conventional ac

    Planning to install a/c in my stone 1940's house. Have been using window units for a few years, which work well and cost me next to nothing in operating costs, but for a lot of reasons we would...
  4. Replies
    4
    Views
    458

    so, just to clarify what I did to get constant...

    so, just to clarify what I did to get constant circulation, the Buderus system always runs on constant circulation when in "day" mode. The only time it does not run on constant circulation is in...
  5. Replies
    4
    Views
    458

    Steve - I use constant circulation because my...

    Steve - I use constant circulation because my daughter's room over the garage gets cold, and leaving it on constant circulation helps keep the temp even throughout the house. That is something I...
  6. Replies
    4
    Views
    458

    Buderus customer support, or lack thereof

    I bought a Buderus oil boiler last year with logamatic control and room sensor. It has taken some work to get it dialed-in just right for my home. For example, I had to set it to constant...
  7. Replies
    4
    Views
    432

    The odor is right near the boiler (not the tank)....

    The odor is right near the boiler (not the tank). No odor when it is not running. It does seem to go away after it has been running for a few minutes.
  8. Replies
    4
    Views
    432

    Critique these combustion test results

    Hi all,

    This is our second year with our Buderus 115/4 section boiler, with Beckett NX burner. It has taken a while to get the programming/settings right, but I finaly feel like I am getting...
  9. Replies
    1
    Views
    469

    Buderus settings help

    Got a Buderus 115 with logamatic control, room sensor, and outdoor reset a few months ago. I have noticed recently that the actual indoor temp is a fair amount higher that the setting on the room...
  10. Gravity, I don't know what any of that means...

    Gravity, I don't know what any of that means ("journeyman techs, member of ACCA, combustion certified"), but that is the kind of thing I am looking for. Thanks.
  11. Look, I don't need a new boiler. I am just...

    Look, I don't need a new boiler. I am just looking for a new oil company. I don't need or necessarily want the cheapest, it is just that mine is consistently $.30 per gallon more than the...
  12. no gas on my street. would cost $16,000 to...

    no gas on my street. would cost $16,000 to extend the gas main.
  13. How to find a good heating oil company...(S.E.Pa.)

    I am shopping aorund for a new heating oil company, as my old one is getting to be just too expensive, even though I like them a lot. Other than searching for reviews of various companies online,...
  14. Replies
    15
    Views
    1,797

    Ok, here's the info from the printed ticket. Let...

    Ok, here's the info from the printed ticket. Let me know what you think.

    T stack 363.7
    Co2. *11.35
    Eff 86.5
    Ex air 36.5
    Oxygen 5.8
    Co. 15 ppm
    Co airfr 21 ppm
    Inh2o draft .0044
  15. Replies
    15
    Views
    1,797

    Sure, will do it later tonight. Keep in mind,...

    Sure, will do it later tonight. Keep in mind, these are from after he made adjustments.
  16. Replies
    15
    Views
    1,797

    Thanks, guys. I think the "not enough air"...

    Thanks, guys. I think the "not enough air" comment was probably dead on, as the guy who came out said I definitely needed a regulator.

    I do have a copy of the analyzer results.
  17. Replies
    15
    Views
    1,797

    You may be right about the set up -- they...

    You may be right about the set up -- they apparently did not do any testing at the time they turned it on (that's the think with the sensor they stick in the boiler and chimney, right?). I had them...
  18. Replies
    15
    Views
    1,797

    p.s. - the sludge was very "oily" feeling.

    p.s. - the sludge was very "oily" feeling.
  19. Replies
    15
    Views
    1,797

    Black Sludge Coming from chimney

    As many of you know, I had a Buderus oil boiler installed a couple weeks ago. Yesterday, I noticed a lot of blackish-green, oozy sludge dripping from the smoke pipe at the joint where it takes a...
  20. Replies
    19
    Views
    2,794

    R Mannino, according to the manual, in the...

    R Mannino, according to the manual, in the "RMSETBACK" mode, which only works with the room sensor installed, the circulator shuts off during night mode unless the room temp drops below the set temp,...
  21. Replies
    19
    Views
    2,794

    OK, sounds like primary/secondary is not a big...

    OK, sounds like primary/secondary is not a big concern with the Buderus, and probably not something I can make them change now, at least not without paying for it. (Does Buderus say anything about...
  22. Replies
    19
    Views
    2,794

    Ok, so I guess I don't really understand what...

    Ok, so I guess I don't really understand what primary secondary piping is. Can someone give me a simple explanation? How would that be different than what I have?

    As for the circulator running,...
  23. Replies
    19
    Views
    2,794

    if i did this right, these should be pics of my...

    if i did this right, these should be pics of my new installation.

    318481

    318491

    318501
  24. Replies
    19
    Views
    2,794

    Yeah, I think that is exactly what happens -- it...

    Yeah, I think that is exactly what happens -- it is getting rid of excess heat into the house, which is fine when it is cold out, but not so great when warmer. It may be mostly a matter of getting...
  25. Replies
    19
    Views
    2,794

    The WWSD is set correctly but the outside temp...

    The WWSD is set correctly but the outside temp was below the WWSD temp so it kept going, even though the room temp was way above where the room temp was set.