  1. Replies
    6
    Views
    820

    It sounds like his unit uses the HSI for flame...

    It sounds like his unit uses the HSI for flame rectification also
  2. Replies
    6
    Views
    820

    when you say "Getting 24v across", do you mean...

    when you say "Getting 24v across", do you mean from pin to pin on each control that should be proving? Cuz of course you should get zero from pin to pin. Anyways, did you take out HSI and give it...
  3. Replies
    19
    Views
    1,499

    you got the SHORT BUS INSPECTOR!! However, if the...

    you got the SHORT BUS INSPECTOR!! However, if the mech room does not have 1 Sq inch per 1000btu at sealevel rating of fresh air, some inspectors call it because they wont consider pipe inlets as...
  4. Thread: trane question

    by ddog1
    Replies
    9
    Views
    711

    Train and AM Standards use reversing valve in A/C...

    Train and AM Standards use reversing valve in A/C . You should make sure Tstat is prog. for orange and r/v in cooling
  5. Replies
    0
    Views
    782

    tridelta pressure switch on carrier furnace

    anyone have the " WC specs for a TRIDELTA HK06WC076? i read it as a .76WC but need to be sure
  6. Replies
    2
    Views
    466

    kenmore chest freezer

    Anyone serviced a kenmore chest freezer with the following symptoms:
    Mod# 25316582102 2yrs old

    1) temp. rise alarm going off

    2) digital temperature located on center handle reading 78...
  7. Replies
    3
    Views
    575

    Lambfamily

    You need to insulate inside cabinet better than it is...it also sounds like you have a low return so if possible bring in a high return. And it is necessary to have fresh outside air in that...
  8. Replies
    5
    Views
    823

    Barriehie

    Pose these questions on the pro tech forums and if your not signed up, its easy and quick to do
  9. Replies
    5
    Views
    823

    Semper Fi

    Hey... your percentage is about right for oem motors. Keep in mind that poorly position fan blades in relation to the shroud can cause high amps ..."chopping".... Also improper run caps even if they...
  10. Wyman

    the no "Tech Help" rule on this site is for your physical protection and our legal protection. That being said, most honeywell systems are homeowner friendly and can be figured out without any...
  11. a little help

    "Clicking" zones usually indicate a striped actuator that in turn indicates too high static pressure due to poor by-pass air volume wich in turn strips actuators and burns out unit blower motors.......
  12. Replies
    16
    Views
    1,173

    My 2 cents

    Its so odd to see this thread today cuz I just finished installing a walk-in cooler and freezer system both new for a local meat processor. As I was kneeling in the wind, Brazing my 7/8" acr copper...
  13. Replies
    8
    Views
    5,433

    Humidifiers

    No excuses not to go with "NEW" honeywell steamers...check them out. Price is reasonable and you can install them up to 20' remote from Supply duct.
  14. Replies
    24
    Views
    1,562

    return

    That 14" return to the 3ton HP is waaaaaay short of required. Some installers will run 16" flex to a 3ton HP thinkin thier ductulator is also a flexulator...still not enough air usually
  15. Replies
    39
    Views
    3,300

    my 2 cents

    That schematic looks pretty basic and considering its all resistance(no heat pump)...your problem should be easily fixed. At first it sounds to me like the factory installed filter in the return of...
  16. Replies
    17
    Views
    1,579

    purpose...Tunnel

    As easy a way I know to explain how to Ground is to let you know the purpose of the ground. Gas lines are not grounded but "BONDED" to the house Neutral or bus bar depending on where the original or...
  17. Replies
    6
    Views
    742

    Tankless

    Where you at and gas or electric?
  18. Thread: kruger diffusers

    by ddog1
    Replies
    2
    Views
    443

    moose

    that be the one....thnx
  19. Thread: kruger diffusers

    by ddog1
    Replies
    2
    Views
    443

    kruger diffusers

    Anybody have the website for kruger diffusers please....thanks
  20. Replies
    14
    Views
    1,265

    troyorr

    I wuz tryin ta be phasicious. I will try harder next time
  21. Replies
    14
    Views
    1,265

    bobelectric

    One of those vendors you mentioned will sell you a motor you need to replace your existing con. fan motor if you DO have an account. The cert. you have qualifies you to change out the electro...
  22. Replies
    11
    Views
    965

    2 cents

    I might get jumped on for this by another tech, but you should know it is possible to de-rate a new 100,000 btu furnace to 70,000 btu by closing up an orfice or two if after install the new furnace...
  23. Thread: Board miss wire

    by ddog1
    Replies
    1
    Views
    490

    I serviced a 3yr old tempstar split system attic...

    I serviced a 3yr old tempstar split system attic furnace today and am kinda stumped. Found fan not working so I checked out the board and find the HI SPEED blower lead connected to the EAC pin on the...
  24. Replies
    7
    Views
    786

    Hey

    Kinda like askin for a reasonably priced pacemaker to save a little money on your tripple bypass ya know....wanna cut out the doc on markup!!
  25. Replies
    11
    Views
    724

    super

    the acid in mortor..concrete will eatup copper.
    for fix I suggest cutting a length of pipe in half and installing after carfully chippin out mortor around lineset