  1. Replies
    129
    Views
    11,058

    Update: Since this was re-opened I wanted to...

    Update: Since this was re-opened I wanted to further comment on the Testo as the OP.
    The set they sent me was my 3rd. It has since failed (pressure readings) and had lasted only a few months....
  2. ^^^ Ditto I usually use a pieceof cardboard...

    ^^^ Ditto

    I usually use a pieceof cardboard and block off to maintain condensing saturation of 95 to 115*F
  3. Replies
    3
    Views
    339

    :bump:

    :bump:
  4. Replies
    3
    Views
    339

    Access to TCS Baysys Superlink

    Need help accessing a Baysys controller. Here is what we have.
    A Superlink (QD2020), a SZ2181 Unit controller and SZ1025a VAV controllers hooked to TS2023 stats.

    The last company only left a...
  5. Replies
    21
    Views
    2,858

    Thinking of the 510 due to the smaller size than...

    Thinking of the 510 due to the smaller size than my current Mannix.
    Something to consider on the Dwyer (I have one also) that the metal body takes a long time to stabilize bringing it in from a cold...
  6. Replies
    127
    Views
    18,807

    Jim B. Thanks for the videos!

    Jim B. Thanks for the videos!
  7. Replies
    127
    Views
    18,807

    Good info Jim, almost ready to buy the Testo 320....

    Good info Jim, almost ready to buy the Testo 320. I want to get something new before the season hits hard. My TSI does have a new sensor though. Could keep it for back up. I think the pump is...
  8. Replies
    18
    Views
    1,419

    1. Call your local HVAC professional. 2....

    1. Call your local HVAC professional.
    2. Evaluate current system
    3. Have them perform Manual J
    4. Manual S
    5. Manual D
    6. Quote for the repair.
    7. Expect to pay for items 2,3,4 & 5.
  9. Replies
    3
    Views
    824

    230V 1 phase wattmeter

    I have a 120VAC "Kill a watt", but looking for something that can handle 230VAC, such as for condensing units to measure true power and not apparent. Anyone have something they use for this?
  10. Actually, BTU/W_H is EER, not to be confused with...

    Actually, BTU/W_H is EER, not to be confused with SEER. EER is "at that instant" where as SEER is "Seasonal" and not easily computed.
    SEER is defined by AHRI and has a standard (ARI 210/240) and...
  11. The Maximum rated ESP is usually .5 for a cooling...

    The Maximum rated ESP is usually .5 for a cooling ready unit and .2 for heat only.
    Most mobile home units such as Intertherm and Coleman that are approved for that application max out at .3".
    You...
  12. P E Chart

    Use the pressure enthalpy chart to plot out a system with the correct SH and SC, then one withhis method.
  13. Please share this with us. I would like to see...

    Please share this with us. I would like to see your numbers.
  14. Replies
    1
    Views
    441

    Acid test kits

    Anything new out there for testing acid on hermetics besides Total Test, Checkmate or those chessy litmus papers?
  15. Replies
    5
    Views
    727

    Digital SMAN3 on the way

    I currently have the Testo 550 and was going to get another for back up. Looked at the Digicool AK900 but was ruled out since there is no factory clamp, only some sort of velcro strap that will...
  16. Thread: CA

    by steve3871m
    Replies
    10
    Views
    700

    I will have to consider your opinion. Can save...

    I will have to consider your opinion. Can save some $$ if I go with the 327.
    It appeared to do more on paper, but if it just graphical I can to ok with just numbers as U taught!
    Just got your...
  17. Thread: CA

    by steve3871m
    Replies
    10
    Views
    700

    Been looking at thek testo 330 L series. My TSI...

    Been looking at thek testo 330 L series.
    My TSI is getting tired but still works great. the 330 is spendy though.

    Ps: Jim D, found the elevation ASHRAE paper.
  18. Replies
    27
    Views
    2,522

    If this was to ever happen then I would be glad...

    If this was to ever happen then I would be glad to move over to Digi-Cool and imagine the same holds true for others. This whole sensor issue is the weak link on the 900's unfortunately.
  19. Replies
    36
    Views
    2,160

    Inspect your manifold and or burner alignment. ...

    Inspect your manifold and or burner alignment. This problem can occur if it is off, usually the Z axis.
  20. Replies
    15
    Views
    1,696

    The Robertshaw replacement is problematic. I...

    The Robertshaw replacement is problematic. I believe this is the one Johnstone supply is providing.

    Most of the time the spark gap is hard to get correct and if it does lite, the switch doesn't...
  21. Replies
    27
    Views
    2,522

    After I posted I seen a few threads on...

    After I posted I seen a few threads on modifications. Seems it would be easier to buy the 1250 clamps and modify the plug in, rather than reworking the whole velcro strap.
  22. Replies
    27
    Views
    2,522

    Digi-Cool AK900 Temp Probes

    Currently have the Testo 550's (2nd set via warranty) and looking for another set of digital gauges. Was all ready to get the Digi-Cool AK900, but the deal breaker seems to be you can only use the...
  23. I'm between 4,200 and 6,500 feet (depends on...

    I'm between 4,200 and 6,500 feet (depends on where my call is at) and concur with ASHRAE and Jim. There are only two brands and a specific model/btu within the brands that I have to derate most...
  24. Thread: CO2 Meter

    by steve3871m
    Replies
    5
    Views
    731

    Ventilation. The Co2 will let you know how...

    Ventilation.
    The Co2 will let you know how effective ventilation (fresh air) in an occupied space is.
  25. Thread: CO2 Meter

    by steve3871m
    Replies
    5
    Views
    731

    CO2 Meter

    Been searching the net and looking at hand held CO2 meters. Most of them come with temp and humidity which I don't need. (already have those tools)
    Data logging would be nice.

    What are you guy's...