Search:

Type: Posts; User: BALloyd

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    31
    Views
    793

    Never had the displeasure. Sent from my...

    Never had the displeasure.

    Sent from my SM-N910W8 using Tapatalk
  2. Replies
    31
    Views
    793

    Only thing worse than a Scotsman cuber is a...

    Only thing worse than a Scotsman cuber is a Scotsman flaker.

    Scotsman flakers are the biggest piles of c$%p going.

    Sent from my SM-N910W8 using Tapatalk
  3. Replies
    25
    Views
    565

    Seen that a few times. Sent from my SM-N910W8...

    Seen that a few times.

    Sent from my SM-N910W8 using Tapatalk
  4. Replies
    15
    Views
    396

    Moisture infiltration, defrost too long, and/or...

    Moisture infiltration, defrost too long, and/or no fan delay coming out of defrost.

    Sent from my SM-N910W8 using Tapatalk
  5. Read this document. ...

    Read this document.

    https://drive.google.com/file/d/0B5GVdW0PM_fZOVdzNW14UkJNUVE/view?usp=drivesdk

    Part number is different.

    Sent from my SM-N910W8 using Tapatalk
  6. Replies
    18
    Views
    626

    Should we start the pool now? I say he calls at...

    Should we start the pool now? I say he calls at 5:15pm Friday.

    Sent from my SM-N910W8 using Tapatalk
  7. Is it a multi tap motor with a lower speed tap...

    Is it a multi tap motor with a lower speed tap for fan only operation? Did you ohm out motor windings?

    Sent from my SM-N910W8 using Tapatalk
  8. Good to know. It would not be the first time...

    Good to know. It would not be the first time Carrier provided me with incorrect info. They were pretty adamant that their Web portal was the only remote access solution with the infinity touch.


    ...
  9. Replies
    13
    Views
    424

    Half past never? [emoji14] Sent from my...

    Half past never? [emoji14]

    Sent from my SM-N910W8 using Tapatalk
  10. Replies
    38
    Views
    826

    All brands have their quirks. All about the...

    All brands have their quirks. All about the installation.

    We have a couple Keeprites in a Spa that suck in chlorine laden air from the pools. They have run for several years with minimal issues. ...
  11. The SAM module will allow access to the Infinity...

    The SAM module will allow access to the Infinity touch controller, but only allows it to read information. All remote access for changing setpoints and such relies on Carrier's Web portal.

    I...
  12. Replies
    38
    Views
    826

    Keeprite A/C and furnaces are just rebadged...

    Keeprite A/C and furnaces are just rebadged Nordyne equipment.

    Sent from my SM-N910W8 using Tapatalk
  13. Replies
    21
    Views
    1,466

    WTF..... Sent from my SM-N910W8 using...

    WTF.....



    Sent from my SM-N910W8 using Tapatalk
  14. OP said it was a produce box. Going to suck all...

    OP said it was a produce box. Going to suck all the moisture out of the customers product at those TD'S.

    Should be maximum of 10F TD.

    Sent from my SM-N910W8 using Tapatalk
  15. Replies
    8
    Views
    339

    It is an awesome tool. It does not replace a plug...

    It is an awesome tool. It does not replace a plug in large ship vac for big jobs, but for small jobs and dragging onto rooftops it is great.

    Sent from my SM-N910W8 using Tapatalk
  16. BC Safety Authority issues electrical and gas...

    BC Safety Authority issues electrical and gas tickets

    ITABC should be able to get you replacement Red Seal refrigeration ticket.

    You could just drive around with your 8.5 x 11 copies mounted...
  17. Replies
    8
    Views
    1,105

    The should have kept back filling until that...

    The should have kept back filling until that entire condenser mess disappeared.

    Sent from my SM-N910W8 using Tapatalk
  18. Thread: Tube Bender

    by BALloyd
    Replies
    2
    Views
    184

    Yes mandrels can be replaced. Yellow Jacket sells...

    Yes mandrels can be replaced. Yellow Jacket sells them individually.

    Sent from my SM-N910W8 using Tapatalk
  19. Good old Rheem/Ruud with their UV Soluble...

    Good old Rheem/Ruud with their UV Soluble equipment labels.

    Sent from my SM-N910W8 using Tapatalk
  20. If it is hot gas that would likely work, but very...

    If it is hot gas that would likely work, but very short for electric defrost.

    Sent from my SM-N910W8 using Tapatalk
  21. Replies
    40
    Views
    786

    Low vs what? What was nameplate FLA? If it is...

    Low vs what? What was nameplate FLA?

    If it is significantly lower, centrifugal fan is not doing any work, therefore not moving enough air. As others have said, TESP can be deceiving if there are...
  22. Replies
    40
    Views
    786

    PSC motor? What was you amp draw on the high...

    PSC motor? What was you amp draw on the high speed wire? What was nameplate amperage?

    Sent from my SM-N910W8 using Tapatalk
  23. Transformer. Sent from my SM-N910W8 using...

    Transformer.

    Sent from my SM-N910W8 using Tapatalk
  24. Thread: Thanks, York!

    by BALloyd
    Replies
    19
    Views
    1,371

    Every Carrier airhandler or coil we install I...

    Every Carrier airhandler or coil we install I have to remove the cover and adjust all of the distributor tubes because there are always at least 1-2 potential rub through spots. The factory just...
  25. Thread: Psig and psia

    by BALloyd
    Replies
    81
    Views
    1,557

    No. You are wrong. PSIA is a measurement of...

    No. You are wrong. PSIA is a measurement of pressure relative to a perfect vacuum.

    PSIG is a measurement of pressure relative to atmospheric pressure, and changes based on altitude as the...
  26. Replies
    37
    Views
    1,441

    Define what you mean by not pumping down. ...

    Define what you mean by not pumping down.

    Most new Copeland scrolls will not pump down below 20-30psig by design to prevent hacks from running them in a vacuum.

    Sent from my SM-N910W8 using...
  27. Replies
    37
    Views
    1,441

    Possible non-condensibles. Sent from my...

    Possible non-condensibles.

    Sent from my SM-N910W8 using Tapatalk
  28. Probably comes with the results of the secret...

    Probably comes with the results of the secret squirrel leak detector showdown some dude was selling awhile back.

    Sent from my SM-N910W8 using Tapatalk
  29. Replies
    9
    Views
    388

    It is communicating setup and Carrier/Bryant uses...

    It is communicating setup and Carrier/Bryant uses demand defrost with two thermistors on communicating systems.....so not in this case.


    Sent from my SM-N910W8 using Tapatalk
  30. Thread: lockout relay

    by BALloyd
    Replies
    32
    Views
    1,059

    Lots of good information posted, but just get...

    Lots of good information posted, but just get some ICM220 lockout relays and wire them up.

    We use these on the cheap Carrier RTU'S that will cycle on the pressure switches because the board has...
  31. Replies
    11
    Views
    441

    Brookfield was in a partnership with Johnson...

    Brookfield was in a partnership with Johnson Controls as a facilities management service company but Brookfield bought out JCI last year, hence the name change. JCI also maintains their own HVAC/R...
  32. Replies
    25
    Views
    793

    Time to call Sparky. They make a career out of...

    Time to call Sparky. They make a career out of fishing and tracing wire.

    Sent from my SM-N910W8 using Tapatalk
  33. Replies
    264
    Views
    4,877

    Sorry but hvacrmedic explanation was correct and...

    Sorry but hvacrmedic explanation was correct and your math is way off, otherwise plumbers are all going to have their heads explode when they learn they have being doing it all wrong.

    For example...
  34. Replies
    59
    Views
    3,777

    EPR'S are installed on the suction line, not on...

    EPR'S are installed on the suction line, not on the liquid line.

    Evaporator saturation pressure is measured on the suction after the metering device.

    They are referred to as an Open on Rise...
  35. Replies
    59
    Views
    3,777

    EPR valves are used a lot refrigeration with...

    EPR valves are used a lot refrigeration with multiple evaporators on the same system or circuit. Think of supermarket cases. It allows you to run some cases at higher coil temperatures for different...
  36. Replies
    9
    Views
    872

    No 2 psi residential gas in your area? Helps keep...

    No 2 psi residential gas in your area? Helps keep those line sizes down.

    Sent from my SM-N910W8 using Tapatalk
  37. Replies
    1,150
    Views
    123,254

    There is a setting somewhere to change from RARH...

    There is a setting somewhere to change from RARH to RAWB. I think it is in the settings for the actual probe itself.

    Sent from my SM-N910W8 using Tapatalk
  38. X2. That is why they invented coring drills. Not...

    X2. That is why they invented coring drills. Not to mention if it was a natural gas line it would be a code violation and safety hazard, so why would you want refrigerant lines under there.
  39. I hear Fieldpiece has great customer service. ...

    I hear Fieldpiece has great customer service.

    Sent from my SM-N910W8 using Tapatalk
  40. Replies
    17
    Views
    830

    X2 Sent from my SM-N910W8 using Tapatalk

    X2

    Sent from my SM-N910W8 using Tapatalk
  41. Replies
    16
    Views
    752

    We have a couple of those beasts on a couple...

    We have a couple of those beasts on a couple supermarkets.

    Sent from my SM-N910W8 using Tapatalk
  42. Thread: Kills me....

    by BALloyd
    Replies
    28
    Views
    1,013

    Amateur. .....you mean you don't have the label...

    Amateur. .....you mean you don't have the label maker that prints labels onto shrink tube?

    Sparky I was working with showed me his today. Pretty slick.

    Sent from my SM-N910W8 using Tapatalk
  43. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    Yes. Looks fine. Sent from my SM-N910W8 using...

    Yes. Looks fine.

    Sent from my SM-N910W8 using Tapatalk
  44. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    Definitely something wrong with this one I got....

    Definitely something wrong with this one I got. Same micron gauge. Will not pull below 5000 microns. Cannot find any leaks.

    Sent from my SM-N910W8 using Tapatalk
  45. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    I sent Christian a PM already. Sent from my...

    I sent Christian a PM already.

    Sent from my SM-N910W8 using Tapatalk
  46. Thread: Kills me....

    by BALloyd
    Replies
    28
    Views
    1,013

    That is called "Too lazy to get a 90 connector."...

    That is called "Too lazy to get a 90 connector."

    Sent from my SM-N910W8 using Tapatalk
  47. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    Thank you. This one is not even close to that at...

    Thank you. This one is not even close to that at all.

    Sent from my SM-N910W8 using Tapatalk
  48. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    I can try on a recovery cylinder, but I have...

    I can try on a recovery cylinder, but I have never had an issue testing a vacuum pump before by hooking up a micron gauge directly to it.

    I am not expecting it to hold on such a small volume, but...
  49. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    This is not on a system. Vacuum gauge hooked...

    This is not on a system. Vacuum gauge hooked directly to vacuum pump. All other ports capped.

    My yellow jacket pump will pull below 50 microns.

    Tried 2 different vacuum gauges with the same...
  50. Thread: Appion TEZ8

    by BALloyd
    Replies
    41
    Views
    1,527

    Appion TEZ8

    Quick question for someone who owns this unit

    If you hook up your vacuum gauge directly off the unit with all the other caps on, should it pull down to 50 microns or below rather quickly like I...