Search:

Type: Posts; User: Frostmonkey74

Page 1 of 14 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    74
    Views
    5,265

    496121 Here's my set up on a Titan four valve...

    496121

    Here's my set up on a Titan four valve manifold... As you can see no need for additional fittings. Been using the Ak900s for about 9 months now.. Glad I made the jump to Digital gauges..
  2. Replies
    74
    Views
    5,265

    Mines a 4 valve manifold..

    Mines a 4 valve manifold..
  3. Replies
    74
    Views
    5,265

    I've mounted my digicool a to a Titan manifold .....

    I've mounted my digicool a to a Titan manifold .. Direct mount no adapters required!
  4. As a Canadian and a certified gas fitter I know...

    As a Canadian and a certified gas fitter I know first hand you cannot service gas fired appliances with out a gas fitters license .. It doesn't matter if you're an electrician .. To get a gas license...
  5. Replies
    132
    Views
    8,801

    I've had dewalt and makita.. But have been using...

    I've had dewalt and makita.. But have been using Milwaukee for the past 10+ years.. I never used ridged but know some guys who do.. They seem to get on average 2-3 years out of them.. Where as I get...
  6. Replies
    14
    Views
    1,518

    Trying braze a new stub in that valve is a bad...

    Trying braze a new stub in that valve is a bad idea. You'll end up damaging the seat in the valve rendering it useless .. Can it be done sure but why would you.. Either install it with out the valve...
  7. Replies
    590
    Views
    100,983

    Today I went to finish off a call started by...

    Today I went to finish off a call started by another tech.. Original call was furnace fires but quickly goes out.. Tech diagnosed faulty secondary reg... I arrive at the house with new reg in hand,...
  8. Carrier and Bryant are enfact from the same...

    Carrier and Bryant are enfact from the same manufacturer .. You do not have to be a carrier or Bryant dealer to service the equipment.. However you do have to be to complete warranty wrk for. Them !
  9. Typically building maintenance guys know very...

    Typically building maintenance guys know very little about HVAC ...
  10. I agree it would be simpler to just switch R ......

    I agree it would be simpler to just switch R ... A simple sp switch would do the job... Too bad there's no wifi ... That's be ideal!!
  11. Replies
    10
    Views
    808

    Oil traps have nothing to do with how long the...

    Oil traps have nothing to do with how long the pipe run is, it's to do with the height of the riser.. If the riser is 15' or more you need a p-trap to aid in oil return up the riser...
  12. Condo Heatpump Problem - Is this a thermostat issue?

    Nope not a ptac. Any standard heat pump tstat will work for you. It's best to have a professional install this for you .. Looks like that coil could use a good cleaning as well!
  13. Post a pic and well be able to tell!

    Post a pic and well be able to tell!
  14. Replies
    27
    Views
    3,874

    I serviced a heat pump today and the disconnect...

    I serviced a heat pump today and the disconnect was mounted on the service panel ... The guy was an electrician and wired the unit himself... I have him a hard time for doing it.. There's on...
  15. Replies
    27
    Views
    3,874

    At least he didn't mount the disconnect there!! ...

    At least he didn't mount the disconnect there!!
    :-/
  16. What kind of heat pump?? Is it a ptac?

    What kind of heat pump?? Is it a ptac?
  17. I'm glad someone chimed in with the truth....

    I'm glad someone chimed in with the truth. Suction line heat exchangers in my experience are common place in large systems ie supermarket refrigeration .
  18. Replies
    18
    Views
    2,925

    Sounds like a fishing expedition !!

    Sounds like a fishing expedition !!
  19. Replies
    5
    Views
    263

    I was having this issue with a compressor on a...

    I was having this issue with a compressor on a walkin cooler last week.. The run wires on the compressor terminals were loose.. Just a thought..
  20. Wow have never seen anyone attempt that before!!...

    Wow have never seen anyone attempt that before!! If it were leaking why not remove it???
  21. Replies
    29
    Views
    3,089

    It is 80% by volume. It's simple to figure out...

    It is 80% by volume. It's simple to figure out for each refrigerant.. All you need is the density if the refrigerant.. No need to reinvent the wheel here!
  22. Replies
    9
    Views
    566

    txv for a 5 ton condenser

    Why not use a 5 ton valve???
  23. Replies
    12
    Views
    1,977

    That's just ignorant!

    That's just ignorant!
  24. Why not run the star wire in ploy tuff .. Then...

    Why not run the star wire in ploy tuff .. Then there's no worries and poly tuff is cheap!
  25. Replies
    24
    Views
    3,949

    That looks like a $$$ maker lol

    That looks like a $$$ maker lol
Results 1 to 25 of 347
Page 1 of 14 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event