    PPCL is just stored as a text file. You can...

    PPCL is just stored as a text file. You can technically edit it with notepad, but you should use program editor as it has all of the syntax checking and point resolution built in. If you have an...
  2. The maximum length for an Ethernet cable run is...

    The maximum length for an Ethernet cable run is 100 meters or 328 feet. You were already exceeding that before you moved the server and you made it worse by extending the cable. Adding a switch isn't...
  3. What exactly does the vendor expect the FX07 to...

    What exactly does the vendor expect the FX07 to do, the Modbus-RTU? What connections are available on the refrigeration product? From the looks of it the Xweb500 talks Modbus-RTU to the devices but...
  4. Is the NAE at 5.0? If you do an insert field...

    Is the NAE at 5.0? If you do an insert field device you can re-run the auto discovery and it should rediscover your devices. If you deleted the device but it is still on the bus then the auto...
  5. Replies
    3
    Views
    140

    Does the point latch when it is commanded? I have...

    Does the point latch when it is commanded? I have had issues with these modules before where they don't latch. Not sure of the cause but I cycled power and it started working.
  6. Replies
    3
    Views
    229

    You've got mail. I have never used the tool...

    You've got mail. I have never used the tool personally, but you will probably have to run the tool on the archive machine.
  7. This is a Lab Pressure Controller with Hot Water...

    This is a Lab Pressure Controller with Hot Water Reheat. I have run into a few of these at a lab that utilize the fast acting actuators for the exhaust and supply.

    Here a list of the points in the...
  8. Replies
    4
    Views
    248

    In hand the module should change as you move the...

    In hand the module should change as you move the slider. You might try and remove the signal line from the module and see if it will move that way. I have had to replace a ton of these modules at a...
  9. Replies
    5
    Views
    479

    I don't think this will work as with BACnet part...

    I don't think this will work as with BACnet part of the required message is the Object Type. If you are polling a Multi-State but telling it that you want an Analog Value I don't believe it will...
  10. Replies
    1
    Views
    221

    Metasys version 4 does not support login from a...

    Metasys version 4 does not support login from a 64bit machine. I don't believe that they supported 64bit til version 6. You can try installing the launcher and see if it will launch.
  11. Thread: Siemens TEC ?

    by NickDeal
    Replies
    3
    Views
    187

    If you are not using WCIS you won't see the raw...

    If you are not using WCIS you won't see the raw value. Is global commander reporting a successful command? What version of Insight are you using?
  12. Thread: Siemens TEC ?

    by NickDeal
    Replies
    3
    Views
    187

    Is the Raw value changing for the point? What...

    Is the Raw value changing for the point? What version of WCIS are you using? Version of the 2023 application?
  13. Replies
    1
    Views
    244

    I don't have experience with that particular...

    I don't have experience with that particular version but I have used BabelBusters on several jobs and recommend them. They are easy to configure and for the most part are stable. I had some issues...
  14. Replies
    15
    Views
    1,364

    I don't know about other countries and I don't...

    I don't know about other countries and I don't currently work for JCI, but when I was with them and after when I worked for a large customer a computer loaded with AIM tools was not available for...
  15. Replies
    15
    Views
    1,364

    You can't buy the point schedule. Someone gave it...

    You can't buy the point schedule. Someone gave it to him and if JC knew about it they wouldn't be happy. Nowadays they have it so tied to the branch laptops that it won't work outside of a full blown...
  16. Replies
    11
    Views
    475

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1900...

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1900195.pdf?x=2522#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=275&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cqu...
  17. It probably has a fault. There are no terminal...

    It probably has a fault. There are no terminal settings to setup a TX/IO on a PXM. You just hook them up and as long as there is enough power on the bus they just work. You access them through adding...
  18. Replies
    6
    Views
    335

    There's a lot to doing that. Different control...

    There's a lot to doing that. Different control systems have different issues doing things like this. JCI for instance might not calculate the value in a known time frame. Depending on what is going...
  19. Replies
    8
    Views
    487

    You could use this:...

    You could use this: http://sourceforge.net/projects/bacnetweather/

    Of course you would have to have either a softcontroller or a BACnet/IP panel on site. I have used this previously and it works...
  20. In the site there is a defined Time Server....

    In the site there is a defined Time Server. Someone may have put it there initially to update the time. If there is anything there but the default the system will not let you manually change the...
  21. I recently had a site that had this issue, but...

    I recently had a site that had this issue, but JCI couldn't auto discover the devices. I had to go to each TEC and make them all masters on the PXC. This was the only way that JCI could see them.
  22. Here is a very basic air handler that I used in a...

    Here is a very basic air handler that I used in a class. 464071
  23. Replies
    2
    Views
    361

    From what you have said you had the software...

    From what you have said you had the software installed so you should have it still. In your title the first thing that you mention is the DX-9100. The software that you want doesn't really do...
  24. Thread: NAE Problem

    by NickDeal
    Replies
    14
    Views
    1,026

    I think I remember a flash sheet from many years...

    I think I remember a flash sheet from many years ago saying there was an issue with the SecurityDB xml file getting deleted. You should be able to copy the securityDB from your laptop if you have SCT...
  25. Replies
    4
    Views
    417

    It could be from anything. Writing to a read only...

    It could be from anything. Writing to a read only attribute is only one cause of errors. You could be getting bad CRC headers on the token frames. I would run a diagnostic on the bus. If that comes...