    I've had trouble with those CLO's. If all else...

    I've had trouble with those CLO's. If all else fails if you jump out the CLO it still uses the safties but wont lock out.
  2. Replies
    5
    Views
    356

    good idea I will look them up, a second opinion...

    good idea I will look them up, a second opinion would be great. wish I could have gotten that bypass going.
  3. Replies
    3
    Views
    324

    the times there a changing vfd's

    trying to stay current in this field is like a part time job. been hanging in there my whole career but knew these vfd's would get me eventually. took a day class from Honeywell but that's not...
  4. Replies
    5
    Views
    356

    its about 15 yrs old and we just inherited it....

    its about 15 yrs old and we just inherited it. tried powering on and off but nothing. not much you can do when it goes blank. the control side of vfd"s has always giving me trouble .the whole speed...
  5. Replies
    5
    Views
    356

    vfd with blank display on voyager

    hi guys, I have a trane m-TED600AEBE s-C99H14449M rtu. vfd has a blank display and the fault light is on. it has a bypass but cant even get that to come on. the vfd is a telemecanique m-atv66d16m2...
  6. Replies
    14
    Views
    764

    475251475261 What a difference with the new...

    475251475261

    What a difference with the new burner plate.
  7. Replies
    14
    Views
    764

    Ignitor and inducer are good.Will check orifice...

    Ignitor and inducer are good.Will check orifice tomorrow. Bringing out new burner plate.Never changed one before,hope that's it.
  8. Replies
    14
    Views
    764

    trane ych120 backfiring badly

    Hi Guys, Worked on a M- YCH120B3HODB S- J4B102135D RTU that when it starts it almost explodes.Once it gets going everything checks out fine. pressure is -.20 . The burner plate with...
  9. Replies
    0
    Views
    195

    old honeywell floating t-stat question

    Hi Guys,

    I have some old fan powered boxes with electric reheat and some vav`s with straight cooling. They were controlled with honeywells T641A1003 and T874C1018 floating...
  10. Replies
    1
    Views
    265

    Repairing a Testo 550

    Hi guys, I have a Testo 550 that just started leaking internally on the high side.Has anyone ever ran into this and has anyone ever tried opening their 550 up?
  11. checking charge on aircooled heat pumps in winter

    Hi guys, I can remember checking the refrigerant on air cooled split heat pumps in winter with the factory charge chart
    they used to print on the inside of the panels. Besides weighing in the...
  12. Replies
    19
    Views
    1,209

    Don't know why but when a condencer fan motor...

    Don't know why but when a condencer fan motor goes on a aaon your better off getting repl. directly from aaon. Had a summer when I tried everything then someone from talk straightened me out,almost a...
  13. Replies
    0
    Views
    396

    BAC COOLING TOWER

    Hey Guys,
    Have a BAC Cooling Tower M#VTO-102-MMXR S#U013301602 Center bearing is making some pretty good noise.My question is do i have to rebuild entire fan section or can i just do center...
  14. Replies
    8
    Views
    1,503

    Got it,If I put in 300psi and return in a day or...

    Got it,If I put in 300psi and return in a day or two and temps are ten degrees of each other,what do you think 5psi give or take?
  15. Replies
    8
    Views
    1,503

    Leak testing with nitrogen

    I always thought nitrogen stayed the same pressure in a system even if ambient temps change from one day to another.Do you guys see this to be true?
  16. Thread: blown 5 amp fuse

    by burto
    Replies
    12
    Views
    2,136

    Bet its the economizer.If the factory molex style...

    Bet its the economizer.If the factory molex style plug is still there you could bypass it for now.
  17. Replies
    8
    Views
    656

    Usually when I see a bypass from the supply to...

    Usually when I see a bypass from the supply to help control static it just dumps up in the ceiling,not connected to return,doesnt seem very efficient though.
  18. Replies
    11
    Views
    1,588

    ICM makes a nice Leed/Lag control thats easy to...

    ICM makes a nice Leed/Lag control thats easy to install,havnt had any trouble yet.
  19. Replies
    6
    Views
    930

    I used to like using the old Ranco pres. controls...

    I used to like using the old Ranco pres. controls to control pressures but dont see manafacturers recommending them anymore.
  20. Replies
    6
    Views
    930

    motor master install

    Hey guys, Have some basic A C condencing units and where installing motor-masters to control head preasure. Was wondering who leaves the factory sleeve bearing motors in and who puts in ball bearings...
  21. Replies
    14
    Views
    2,219

    that makes alittle sence.was working in a school...

    that makes alittle sence.was working in a school and the control guy said on his end (building automaition)they dont ground the common,something to do with interference.
  22. Replies
    14
    Views
    2,219

    floating ground ?

    hey guys, been a hvac tech for awhile but never heard of this before.if i come across a 24 volt transformer in say a rtu one side of secondary is grounded,in the control world sometimes you dont have...
  23. Thread: trane tam7 ahu

    by burto
    Replies
    1
    Views
    627

    trane tam7 ahu

    model-tam7a0c42h31sba serial-12212n8tav

    was wondering if this unit comes with any info on the computer board.
    tried starting one late friday and noticed board has lots of l.e.ds incuding police...
  24. Replies
    2
    Views
    639

    having all that stuff in the attic would be kind...

    having all that stuff in the attic would be kind of noisey,any chance of
    zoning the basement unit?
  25. Replies
    75
    Views
    8,640

    verbally should be fine,leaving a notice is...

    verbally should be fine,leaving a notice is good,dont burn any bridges
    its a small a/c world out there.