Search:

Type: Posts; User: ch4man

Page 1 of 20 1 2 3 4

Search: Search took 0.07 seconds.

  1. never had an issue with liquid charging liquid,...

    never had an issue with liquid charging liquid, just gotta keep an eye on the digital scale so you have some idea of how fast yer dumpin it in
  2. you still in midwest Wisconson Chuck?. i've...

    you still in midwest Wisconson Chuck?. i've thought those would be a great deal around here.
  3. Replies
    44
    Views
    2,055

    or.... buy a 5/16th inch 8 point socket.... thats...

    or.... buy a 5/16th inch 8 point socket.... thats 8 pt not 12 pt. worth every penny
  4. Replies
    46
    Views
    2,086

    :pop:

    :pop:
  5. Replies
    44
    Views
    2,055

    sorry, im having a tough day. it takes practice...

    sorry, im having a tough day. it takes practice to get good. you'll get it.

    i have faith. keep up the good work!
  6. Replies
    44
    Views
    2,055

    oh for the love of god! bolt the new motor in...

    oh for the love of god!

    bolt the new motor in the belly band, drop it in the wheel and housing.

    now center the wheel in the housing, tighten the set screw, reinstall assembly and finish wiring....
  7. psyclone lite

    psyclone lite
  8. can you explain the physics behind this, i'm not...

    can you explain the physics behind this, i'm not disgreeing, but that make little sense.

    how can restricting the flow of refrigerant ( say 2 of 6 tubes plugged ) cause the distributor to overfeed...
  9. Replies
    35
    Views
    3,581

    sorry, was just havin fun. dc ak900 by uei is...

    sorry, was just havin fun.

    dc ak900 by uei is what i have- love'm
  10. Replies
    35
    Views
    3,581

    yes, there is..

    yes, there is..
  11. Replies
    5
    Views
    343

    :eek2: wow :eek2: those are horribly...

    :eek2: wow :eek2: those are horribly restrictive. manual D default for calculations and most average H&C registers have a delta P of 0.03"wc.

    i suppose you could do without an evaporator if you...
  12. Replies
    34
    Views
    1,322

    ok, what i see is this, you only have a 10 degree...

    ok, what i see is this, you only have a 10 degree DB split and a 10 deg WB split. DB split can have a wide range but for a 10 deg delta it had better be very hunid in the return. 9-11 deg WB is a...
  13. Replies
    29
    Views
    2,436

    your response sounds to me that your in the...

    your response sounds to me that your in the industry. i've been looking for delta p specifications for some time. filter manufactures seem to not want to share that information.

    do you work for a...
  14. Replies
    29
    Views
    2,436

    and yet, no one mentions that proper sizing is...

    and yet, no one mentions that proper sizing is crucial to maintaining acceptable delta P reguardless of "color"

    ever notice most furnaces with 5 ton blower packages and a 16 x 25 x 1 or even 4"...
  15. i'll give you my version of the same answer...

    i'll give you my version of the same answer everyone has given. just take the pressures of 2 refrigerent tanks, same refrigerant, same temperature, now you tell me, only using pressure which one has...
  16. Replies
    17
    Views
    1,208

    sorry, no part number but carrier has a couple of...

    sorry, no part number but carrier has a couple of parts such as the "small parts bag" used for installation, the kit for all the hoses and one for just the small diameter hoses ( 3/16" ID). high...
  17. Replies
    16
    Views
    821

    let me get this straight, a 50% solution leaks...

    let me get this straight, a 50% solution leaks out and 100% glycols is there at the ready to replace it??

    yeah, i guess if its only a gallon or 2 it'd be ok
  18. Replies
    33
    Views
    1,097

    Yeah, im ready. Just back from a aweek on a...

    Yeah, im ready. Just back from a aweek on a florida beach to 5 inches of snow on my deck yesterday
  19. Thread: LED flashlights

    by ch4man
    Replies
    49
    Views
    5,633

    My first streamlight, a incan stinger lasted...

    My first streamlight, a incan stinger lasted 14years. Sure 2 bulbs a year,a few switches and batterys but it just worked. Now that it diedi have 5 years on a strion that will not quit! They are...
  20. Replies
    7
    Views
    976

    heat loss,,,,,,,,

    this wont answer you question but its true.
    about 10 years ago at deer camp we had a 30,000 btu empire vented space heater in a homemade 10 X 14 ft tent. i had brought up a temperature recorder and...
  21. Replies
    113
    Views
    10,126

    old school......

    these are from 4 years ago, still using the same old box

    http://hvac-talk.com/vbb/attachment.php?attachmentid=46052&d=1251678117
    ...
  22. Replies
    15
    Views
    1,080

    yep, if the throttle valve didnt open you'll have...

    yep, if the throttle valve didnt open you'll have "correct" outlet pressure but the closed throttle valve will further restrict the gas flow. thus "good" measured gas pressure but in fact low CFH
  23. Replies
    15
    Views
    1,080

    so you have correct pressure but not enough gas...

    so you have correct pressure but not enough gas to get close to rated temp rise? where are you measuring gas pressure, at the gas valve or the throttle valve?
  24. Replies
    32
    Views
    2,333

    mind telling us why you think thermocouples are...

    mind telling us why you think thermocouples are better? most believe thermisters, while a bit slower to stabilize are more accurate and consistant
  25. Thread: RPM Question

    by ch4man
    Replies
    7
    Views
    462

    interesting,,,, was that under a nominal load?

    interesting,,,, was that under a nominal load?
  26. Thread: dry cold air

    by ch4man
    Replies
    6
    Views
    782

    this is almost as tough of a concept to teach as...

    this is almost as tough of a concept to teach as is the question " what weighs more dry air or humid air?" way more guys get this wrong than understand.

    psycrometrics is something we all need to...
  27. Replies
    64
    Views
    3,633

    Take an old gas furnace, one that has a multi...

    Take an old gas furnace, one that has a multi sppeed blower, a hw fan/limit, a fan center relay, old school tstat and rip all the wores out of it. Give the new guy a bag full of wires(not the...
  28. Replies
    33
    Views
    3,103

    Yes its one of those,,,,,,, but by the...

    Yes its one of those,,,,,,, but by the description of the intake being burnt black she'sbetter off new....jmho
  29. Replies
    19
    Views
    847

    I wonder if the circ he installed didnt have a...

    I wonder if the circ he installed didnt have a flow check. with that piping arangement you must have IFC's
  30. Replies
    32
    Views
    3,792

    thats just done to keep the rain water from...

    thats just done to keep the rain water from pooling on it
  31. yep, them Canadians are terrible drivers

    yep, them Canadians are terrible drivers
  32. Replies
    28
    Views
    2,379

    thanks, i was always told the black disc that...

    thanks, i was always told the black disc that fries was a MOV..

    probably was told that by "some guy on the internet"

    wait........................................




    no, NTC makes sense..
  33. Replies
    28
    Views
    2,379

    im sorry i thought you were talking a ECM motor....

    im sorry i thought you were talking a ECM motor.

    they act opposite of a PSC motor....

    dont beleive me, try what i said


    read post 19, he said it better than i could
  34. Replies
    28
    Views
    2,379

    by measuring RPMs and the torque to maintain said...

    by measuring RPMs and the torque to maintain said RPMs. that info is mapped in the programming
  35. Replies
    28
    Views
    2,379

    what burns up in the module is the MOV. metal...

    what burns up in the module is the MOV. metal oxide varister. like all electronic components they're rated at a maximum wattage. too high static does increase amp draw on an ECM drive and will...
  36. Replies
    28
    Views
    2,379

    dont believe it? got a piece of cardboard and an...

    dont believe it? got a piece of cardboard and an amp clamp?. see for yourself. start blocking the airflow in the return or filter and watch your ampdraw
  37. Thread: Red Tagged

    by ch4man
    Replies
    29
    Views
    2,968

    well good luck..... btw, nice deer in your other...

    well good luck..... btw, nice deer in your other thread.

    my buddy last weekend, got in his stand at 7:00, shot a 3 pointer at 7:02, got an 8 pointer at 7:04 and was back at camp drinking a beer by...
  38. Thread: Red Tagged

    by ch4man
    Replies
    29
    Views
    2,968

    wow. $hit like that pisses me off. we have a...

    wow. $hit like that pisses me off.

    we have a zero tollerence policy on indoor leaks. i'd be fired so fast if i every tried that.

    sorry your local utility sucks;;;; we're not all that bad.
  39. Thread: Red Tagged

    by ch4man
    Replies
    29
    Views
    2,968

    oh i agree, you found a hack for sure. those...

    oh i agree, you found a hack for sure. those mueller core valves can be regreased with the proper tool. thats what should've happened...

    now it doesnt leak... but its probably rendered useless...
  40. Thread: Red Tagged

    by ch4man
    Replies
    29
    Views
    2,968

    how much was that leaking? LEL? PPM? how did...

    how much was that leaking? LEL? PPM?

    how did you fix it?
  41. or a clue

    or a clue
  42. Thread: Red Tagged

    by ch4man
    Replies
    29
    Views
    2,968

    co2?

    co2?
  43. time to google flashback, port loading and flame...

    time to google flashback, port loading and flame propagation
  44. Replies
    30
    Views
    2,226

    sorry, i came off as such a jacka$$. call it...

    sorry, i came off as such a jacka$$. call it suffering from a really bad day both at work and after. i took it out an here, that was wrong.:oops:

    now. that excerpt below appears to be a "reason"...
  45. Replies
    30
    Views
    2,226

    im in the field working instead of sitting on my...

    im in the field working instead of sitting on my arse in front of a computer where the real work is smart ass......

    now you tell me just how does this rain thing has anything to do with charging a...
  46. Replies
    30
    Views
    2,226

    now who taught you that crock of scat?. i dont...

    now who taught you that crock of scat?.

    i dont work in the rain
  47. Replies
    15
    Views
    2,609

    low pressure isnt that high. 45 deg SST will...

    low pressure isnt that high. 45 deg SST will still dehumidify. its the SLT that's high. 32 deg superheat? that coil is starving man.
  48. Replies
    53
    Views
    11,095

    thank you for this update, please stop by often....

    thank you for this update, please stop by often. a lot of respect is given to those in the industry such as yourself who comes here to see what's happening on the front lines.
    from all my...
  49. Replies
    4
    Views
    1,083

    ive made many, seal the end, drill the sides....

    ive made many, seal the end, drill the sides. done right just as accurate as a dywer a303.

    i like that ones ive made from 1/8" brass tubing from the hobby store. no need to drill a very large hole
  50. Replies
    22
    Views
    1,849

    run, cut your losses and just run.....

    run, cut your losses and just run.....
Results 1 to 50 of 1000