Search:

Type: Posts; User: Branderson0515

Search: Search took 0.00 seconds.

  1. Correct to properly match you need to match the...

    Correct to properly match you need to match the coil but the unit is tripping head pressure almost instantly. Mismatched coil would take longer to trip.
  2. If your txv is bad on the outdoor unit your...

    If your txv is bad on the outdoor unit your suction pressure is in the outdoor coil and the txv starves the coil and your suction pressure will pump down just as if the indoor txv where to lock up in...
  3. Replies
    36
    Views
    2,682

    If you are working on a G26 and the pilot is...

    If you are working on a G26 and the pilot is fluttering before main ignition, make sure you have the rubber gasket on the bottom of the fire box that the pilot tubing goes thru is installed...
  4. I would check 2 things. You mentioned a new...

    I would check 2 things. You mentioned a new filter drier. If it is a liquid line filter drier, is it a biflow?(being it is a heat pump the drier must be a biflow drier) if it is a suction line...