  1. Replies
    12
    Views
    238

    Is the distributor mounted vertical or...

    Is the distributor mounted vertical or horizontal???

    If horizontal is it the top tube not feeding?
  2. Replies
    9
    Views
    1,749

    This was almost 9 years ago... Hope it's fixed or...

    This was almost 9 years ago... Hope it's fixed or replaced by now. :grin2:
  3. Replies
    6
    Views
    340

    Agree, can't go wrong with a Weber. I got a...

    Agree, can't go wrong with a Weber. I got a Genesis 330 about 5 years ago and still looks and works like new... Only thing I've had to do to it was clean some spider webs out of the burner orifices....
  4. Replies
    13
    Views
    803

    I also keep a graingers 1/2 and 1/3 hp universal...

    I also keep a graingers 1/2 and 1/3 hp universal motors on the truck. Don't know the part number off the top of my head though.
  5. Replies
    13
    Views
    803

    AO Smith 9721 will work on almost any walk in...

    AO Smith 9721 will work on almost any walk in cooler or freezer. Also keep a 16w,9w,6w,5w cw 120v on the truck... 50watt motors come in handy too on some smaller condensing units.
  6. Replies
    30
    Views
    1,352

    Ummm didn't the 3" ball valve and smaller...

    Ummm didn't the 3" ball valve and smaller orifices already do that????
  7. Replies
    30
    Views
    1,352

    Changing the pressure switch is a given. :grin2:

    Changing the pressure switch is a given. :grin2:
  8. Replies
    30
    Views
    1,352

    Just add a 3 inch ball valve on the intake.......

    Just add a 3 inch ball valve on the intake.... :whistle:
  9. Replies
    194
    Views
    17,681

    Or install a window shaker in a meat prep room.

    Or install a window shaker in a meat prep room.
  10. Replies
    30
    Views
    1,575

    Sc56 with fluke leads... If only Fieldpiece may...

    Sc56 with fluke leads... If only Fieldpiece may good leads it would be perfect.... And if it had a magnet on the back.
  11. Replies
    3
    Views
    331

    The fieldpiece style is all the same... But who...

    The fieldpiece style is all the same... But who else makes a Dtek Select style leak detector?
  12. Replies
    43
    Views
    1,545

    Soooo what's the superheat???

    Soooo what's the superheat???
  13. Replies
    43
    Views
    1,545

    Maybe take an oil pressure and crank case...

    Maybe take an oil pressure and crank case pressure reading..... Then possibly a superheat reading... That's where I would start.
  14. Replies
    5
    Views
    465

    If the unit is down for a long time temp will go...

    If the unit is down for a long time temp will go up in the freezer causing an increase in crankcase pressure... (Unless there is a CPR valve) Also the temp of the compressor will change causing...
  15. Replies
    13
    Views
    690

    This is what I was thinking.

    This is what I was thinking.
  16. Replies
    52
    Views
    3,010

    That's funny, they must of really liked there...

    That's funny, they must of really liked there brass fittings to take them back out every time they serviced a compressor.... Or maybe 50 years ago they were harder to come by??? Now that I think...
  17. Replies
    52
    Views
    3,010

    So I beat my old record the other day. Just...

    So I beat my old record the other day. Just replaced a 1964 k body for a meat prep room that had never been serviced for anything by the looks of it. Original staring components, lp control, it...
  18. Thread: TRUE GDM-49F

    by Dchappa21
    Replies
    14
    Views
    560

    Just had one leaking on the sight glass the other...

    Just had one leaking on the sight glass the other day... My special tool was a big screw driver and my 12" adjustable used as a hammer. :grin2: but it worked.
  19. Could just use some heat tape and insulate it.......

    Could just use some heat tape and insulate it.... But I agree best spot is outside the box. Even then I will heat tape it.
  20. Replies
    9
    Views
    837

    I don't use pullers often, but wouldn't a small...

    I don't use pullers often, but wouldn't a small square piece of steel work over the shaft?
  21. Guess I should of added is the sight glass full??...

    Guess I should of added is the sight glass full?? Maybe some pressures
  22. Check the superheat... If its ok 4-6 degrees,...

    Check the superheat... If its ok 4-6 degrees, don't touch it.

    If its not then the first thing I would do is pump it down and clean the screen.
  23. 3/4" wall for a freezer... Use 1/2" for...

    3/4" wall for a freezer... Use 1/2" for coolers... Sometimes I use 1" on freezers and 3/4" on med temp, just because I only like to do it once.
  24. Turn it back on... Your compressor is going to...

    Turn it back on... Your compressor is going to sound loud because your box is wicked warm. If your really worried about the compressor over ampping you can throttle the suction service valve to keep...
  25. Replies
    2
    Views
    175

    Yes, yes, And no.... Much more reliable then the...

    Yes, yes, And no.... Much more reliable then the old mechanical 8145 series.