Search:

Type: Posts; User: noskilltech

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    613

    Getting a paycheck. And knowing I can't live...

    Getting a paycheck. And knowing I can't live forever.
  2. Replies
    44
    Views
    2,322

    http://www.gftexas.com/images/gas-can-photo.pnghtt...

    http://www.gftexas.com/images/gas-can-photo.pnghttp://etc-mysitemyway.s3.amazonaws.com/icons/legacy-previews/icons/rounded-glossy-black-icons-alphanumeric/074184-rounded-glossy-black-icon-alphanumeric...
  3. Yeah, I was about to say try port 4911

    Yeah, I was about to say try port 4911
  4. Replies
    9
    Views
    744

    He's trying to become a controls tech. If he...

    He's trying to become a controls tech. If he already had skills, I would highly suggest your post.

    He should dress clean and make sure he spells everything right on the application. With the...
  5. Replies
    8
    Views
    455

    You can pick up the NAE's with an FX server with...

    You can pick up the NAE's with an FX server with no problems if you license your server for Bacnet and also enable Bacnet on your NAE's. You'll probably want to can the ADS/ADX since it would be...
  6. Replies
    21
    Views
    1,395

    Why would you ever possibly need bacnet when you...

    Why would you ever possibly need bacnet when you have metasys? Silly controls guys.
  7. Sorry, I meant ActionButton. It should be in...

    Sorry, I meant ActionButton. It should be in your kitPx palette.

    If you go to config under your station, right click on it and select the property sheet view. Then under Sys Info, you can add...
  8. Also, I'll usually just add it to the entire...

    Also, I'll usually just add it to the entire station. I hate it when people override stuff and then call to complain their ish doesn't work right and the control system is effed up then you go in...
  9. Graphics? How did NASA get half a RTU on the...

    Graphics? How did NASA get half a RTU on the moon with two different manufacturers compressors in it? And I wasn't aware the beach with a romantic sunset was on the moon either.

    All joking...
  10. Replies
    2
    Views
    300

    Have you patched your Jace for the 3.8.38.1 web,...

    Have you patched your Jace for the 3.8.38.1 web, gx, etc.. so you can run JRE 7_65 yet?

    FYI, I wouldn't post pics with IP's and your username anywhere on the internets. Some ahole will come along...
  11. http://i.imgur.com/i1SWjAA.png

    http://i.imgur.com/i1SWjAA.png
  12. Replies
    6
    Views
    651

    Zigbee is your friend in this situation. You...

    Zigbee is your friend in this situation.

    You could always use the Viconics/Schnider TEC's and a Jace. You don't even need a driver for the WirelessStatNetwork.
  13. Replies
    299
    Views
    29,370

    That's like only being with one woman your entire...

    That's like only being with one woman your entire life and saying she has the greatest vagina in the world. How do you know if you don't sample other vaginas?

    Go ahead, sample others and choose...
  14. Replies
    0
    Views
    191

    Weather Service Advisories

    Anyone know how I can add the description text from weather service alarms into an email alarm?
  15. Replies
    29
    Views
    1,249

    Can you ping it?

    Can you ping it?
  16. First, you get what you pay for. Second, you...

    First, you get what you pay for.

    Second, you could look into the Easyio controllers. The 30P is probably the cheapest, but you'll need sedona workbench to program it. The FG series controllers...
  17. I tried to months ago whe 3.8 first came out, but...

    I tried to months ago whe 3.8 first came out, but couldn't get it to work. I think at the time, Distech had not put out their 3.8 evil java wizzardry. I haven't tried it since.
  18. Negative. Several building owners I know found...

    Negative. Several building owners I know found out the hard way that arc156 is not MS/TP. And you cannot add MS/TP devices without ALC's AMR router. Which is all fine and dandy until they no longer...
  19. Replies
    5
    Views
    343

    My bad. I misread your post and thought they...

    My bad. I misread your post and thought they were temp sensors. For the static transducers, you'll have to do some math functions in DDC to get the values you want. I can't remember honestly what...
  20. Replies
    5
    Views
    343

    Since the TX-450 has no memory any programming...

    Since the TX-450 has no memory any programming done in it was done in the old Apex. To fix your input, you need to go into the DDC on the BCM TUX and add a line for a temperature convert, which I...
  21. Replies
    8
    Views
    606

    Yeah, it's weird. Like I said, don't ask me why...

    Yeah, it's weird. Like I said, don't ask me why that did the trick because honestly I don't know and it seems crazy if you really start to thinking about it, but as long as you get the desired...
  22. Replies
    55
    Views
    4,573

    Don't take that post as too serious. I was just...

    Don't take that post as too serious. I was just doing my part to fuel the flames of arguments past. We have very little if any lon in my market. Really the only lon around here is a handful of...
  23. Replies
    8
    Views
    606

    I had the same problem about two months ago. I...

    I had the same problem about two months ago. I set up my network and all looked well like the device was there even when I disconnected the comm line but all my points were in fault. My fix was...
  24. Replies
    55
    Views
    4,573

    I'm just poking the old lon vs bacnet bear. I...

    I'm just poking the old lon vs bacnet bear. I think 10 years ago there could have been a debate between lon and bacnet, these days not so much. For the end user, if their system works and they get...
  25. Replies
    55
    Views
    4,573

    Lonworks is great if you want to completely...

    Lonworks is great if you want to completely overcomplicate and overengineer a buildings system, but still have derelicts with no skills install it.

    Bacnet is a gentlemans control system. ...
  26. Replies
    55
    Views
    4,573

    Really dude? FT-10? Pfft!

    Really dude? FT-10? Pfft!
  27. This should suffice for most engineered systems....

    This should suffice for most engineered systems.

    http://basands.com/files/1395183567.png
  28. Replies
    16
    Views
    1,171

    I would have to second the EasyIO. The new FG32...

    I would have to second the EasyIO. The new FG32 is a very powerful controller wrapped into one little package and support is first class.

    Also I would have to say Loytec as well.
  29. Replies
    4
    Views
    424

    I would serial shell the jace to clear out the...

    I would serial shell the jace to clear out the platform password then use workbench to connect to the platform, go to the File Transfer Client and then copy the N2Slave driver into your workbench. ...
  30. Send the IT department a heft bill for your time...

    Send the IT department a heft bill for your time and software. They typically run on budgets just like everyone else and money usually talks.
  31. Replies
    17
    Views
    1,190

    I had a job that required two L-VIS displays last...

    I had a job that required two L-VIS displays last summer. The entire system was mostly bacnet IP with easyio 30P's to an Ax server. It was a pretty cool job since all I had to do was mount panels...
  32. Replies
    12
    Views
    851

    That is the exact attitude of the turdherders and...

    That is the exact attitude of the turdherders and tin banging monkeys I deal with daily that try to put a visionpro on custom AHU's that they design build and get upset when it costs them more than...
  33. Replies
    17
    Views
    1,190

    If you need a touchpanel, just get a Loytec. ...

    If you need a touchpanel, just get a Loytec. They are great products, and their support is top notch. For our industry, there really isn't any comparison.
  34. Replies
    6
    Views
    543

    Those things were a headache on their best day. ...

    Those things were a headache on their best day. When I worked for the blew oval company we would avoid selling comfortworks.

    From what I remember on comfortworks, make sure your sql services are...
  35. Replies
    4
    Views
    348

    Did you install the module on the platform with...

    Did you install the module on the platform with the software manager?
  36. Replies
    7
    Views
    518

    Now this got my wheels turning this morning...

    Now this got my wheels turning this morning thinking about this. And yes, you can do it once you change the web services http and https and also the fox port. At least on my workbench machine you...
  37. Replies
    11
    Views
    955

    I started out in a place like that. Best thing...

    I started out in a place like that. Best thing you can do is have initiative. To get ahead in the controls world, you have to go above and beyond. Countless hours being away from your home and...
  38. http://cgproducts.johnsoncontrols.com/CAT_PDF/1900...

    http://cgproducts.johnsoncontrols.com/CAT_PDF/1900350.PDF?x=6

    If you go away from the JCI sensor, you're going to have to reprogram the zn-t and znt-sp points in CCT to reference a different input...
  39. Replies
    2
    Views
    282

    If the supervisor is a windows based machine,...

    If the supervisor is a windows based machine, then you'll need the windows login information to access the platform. I don't believe there is any easy way around hacking the windows password.
  40. Replies
    23
    Views
    2,104

    Over the years I've come to find out that there...

    Over the years I've come to find out that there are two types of IT personnel. I can usually figure out what type they are within a minute of asking them for remote access to their system.

    Type1:...
  41. Replies
    11
    Views
    812

    Join the party man. I've been doing a Modbus to...

    Join the party man. I've been doing a Modbus to Niagara job the last few weeks with smart breaker panels for lighting control. Fortunately all my points are simple coils that come in as Boolean...
  42. Replies
    34
    Views
    5,278

    This will make everyone's life easier. ...

    This will make everyone's life easier.

    http://bacnetworks.com/uploads/
  43. Replies
    4
    Views
    298

    You da man! That was the ticket. Thanks.

    You da man!

    That was the ticket.

    Thanks.
  44. Replies
    4
    Views
    298

    Ax timed setpont override release

    I wanted to ask of some of you Ax experts if you know of a simple way to release a setpoint override based on time of day.

    Basically I need to allow the managers to be able to make a room 2...
  45. Replies
    34
    Views
    5,278

    Sent

    Sent
  46. I love these kinds of problems. I plugged into...

    I love these kinds of problems. I plugged into it this morning with modscan and bam! Everything was there. Plugged it back into my jene, made a new network, and voilia, points would start talking...
  47. Replies
    6
    Views
    709

    I've seen the same thing with the latest and...

    I've seen the same thing with the latest and greatest version of 3.7.106. I can't open stations that are 3.7.44 and if they do open, some of the things are buggy like trying to add devices to Bacnet...
  48. I'm still fighting with this thing just to get it...

    I'm still fighting with this thing just to get it to communicate now. Anyone know if you have to enable the RS-485 port inside the powerlink controllers to get it to spit out data? I've checked...
  49. Thanks refrepairman, but I'm not connecting a PC...

    Thanks refrepairman, but I'm not connecting a PC to the panel. Things would probably be easier if I were to go that route. I did get some vague information back from schneider that is getting me...
  50. Square D PowerLink Lighting control to Ax

    Has anyone had the lovely opportunity to tie into one of these breaker panels via RS-485? I can't even seem to find anything online for a modbus data map so I've emailed their tech support after...
Results 1 to 50 of 380
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event