Search:

Type: Posts; User: OuTcAsT

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Bump

    Bump
  2. COMMERCIAL TECH NEEDED, Little Rock, AR and surrounding area

    COMMERCIAL HVAC SERVICE/MAINTENANCE TECHNICIAN
    Seeking experienced, self-motivating candidate, to service light commercial package RTUs from 2 to 30 tons. Customer is a big-box retail chain.
    Must...
  3. Bump.

    Bump.
  4. Replies
    31
    Views
    2,421

    In the commercial end, it is our policy to shut...

    In the commercial end, it is our policy to shut off the gas, disable the "W" circuits, and the equipment is not re-activated until repairs are completed. I would not ever try and "patch" an HX on a...
  5. Bump :whistle:

    Bump :whistle:
  6. Light Commercial Service/ Maintenance Tech Needed in Nashville TN

    I have an opening for a service/ maintenance tech in my company, servicing Mainly RTU's from 1 to 30 Tons.

    Minimum 5 years experience
    Clean Driving Record
    EPA Certified
    Must be computer...
  7. Replies
    65
    Views
    8,304

    No way, I would not touch that. Once you have...

    No way, I would not touch that. Once you have done all this repair work, it is yours forever. If the compressor fails in the spring he's gonna want you to cover it under "warranty". Ya gotta know...
  8. Replies
    34
    Views
    5,729

    Definitely seen worse, not by much though.

    Definitely seen worse, not by much though.
  9. Replies
    66
    Views
    12,583

    The Z-Arm lift would work, I actually suggested...

    The Z-Arm lift would work, I actually suggested they buy one for the site. Looks like they may relocate the units to the ground level, I HOPE !
  10. Replies
    66
    Views
    12,583

    tell them they need to buy one of these and store...

    tell them they need to buy one of these and store it onsite for service LOL
    http://www.wieseusa.com/cmss_files/imagelibrary/skyjack_group.jpg





    Sorry, thought of that but, because the...
  11. Replies
    66
    Views
    12,583

    Just got word today, I have to go meet with a...

    Just got word today, I have to go meet with a steel fabricator this week at this site. We got the store AND they are gonna build catwalks to our specifications ! We suggested placing the units on...
  12. Replies
    17
    Views
    2,394

    Carrier uses Danfoss as replacements on almost...

    Carrier uses Danfoss as replacements on almost all scrolls now, and they are all about 1" shorter than the originals.
  13. Replies
    7
    Views
    1,404

    !995 Single stage , single phase condenser...

    !995 Single stage , single phase condenser section, R-22 , 5 Nominal tons .
  14. Replies
    4
    Views
    1,195

    The Novar 3051 T is a proprietary control and...

    The Novar 3051 T is a proprietary control and monitoring module. It uses a zone sensor to monitor the space temperature, and a discharge air sensor to monitor the output of the unit. It communicates...
  15. Thread: Balancing act

    by OuTcAsT
    Replies
    9
    Views
    1,851

    Heh, no way am I putting myself, or one of my...

    Heh, no way am I putting myself, or one of my Techs in that position. Not worth it.:.02:
  16. Replies
    66
    Views
    12,583

    You are correct y7turbo, and they are an...

    You are correct y7turbo, and they are an excellent customer, they asked our opinion, and I told them they should either get the installing contractor to put them on the ground correctly installed, or...
  17. Replies
    66
    Views
    12,583

    No, did not bid this job, Told them we would not...

    No, did not bid this job, Told them we would not touch it with a 10' pole...especially since the pole would not reach anyways :D:D

    The building was a prefab type construction with a tin roof, not...
  18. Replies
    66
    Views
    12,583

    How NOT to install commercial package units...

    http://i875.photobucket.com/albums/ab312/dbruner/5.jpg http://i875.photobucket.com/albums/ab312/dbruner/4.jpg http://i875.photobucket.com/albums/ab312/dbruner/3.jpg...
  19. Is this a Voayger unit ? Fault codes would help,...

    Is this a Voayger unit ? Fault codes would help, but sounds like the High pressure control is tripping. Do you have guages on when it trys to start?
  20. Thread: Gas regulator

    by OuTcAsT
    Replies
    9
    Views
    1,079

    Should work either position. As previously noted,...

    Should work either position. As previously noted, make sure the arrow is pointed the right way ! Also, if mounted horizontally, be sure the vent is protected from water/ ice accumulation.
  21. Thread: Chile Addicts

    by OuTcAsT
    Replies
    3
    Views
    1,518

    These chilis have a wonderful flavor that cannot...

    These chilis have a wonderful flavor that cannot be found in other peppers. The trick to enjoying them, (without spending time in the bathroom wiping your a$$ with a snowcone) is not to eat the seeds...
  22. Replies
    1
    Views
    512

    New refrigerant prices/ Alternatives

    As most are aware, the price of R-22 is getting astronomical , at the moment we are able to pass the cost along o our customers, however this may soon be a problem. Have any of you used, or plan to...
  23. The consensus was incorrect, a no-load condition...

    The consensus was incorrect, a no-load condition would not prematurely burn out a motor, and the motor has an internal fan for cooling.
  24. The rate of starting pay will be based on...

    The rate of starting pay will be based on experience, we pay better than most !

    :yes:
  25. Commercial HVAC Tech needed it Conway/ Little Rock ARKANSAS Area Immediately !

    Light commercial only, must have good driving record, 5 years experience as a TECHNICIAN, Fax resume to 800-413-3693 or email to danebruner@gmail.com
  26. Quickbooks online is perfect, and your records...

    Quickbooks online is perfect, and your records are stored on a server, not your computer. I use Microsoft Outlook as my email client, and also as dispatching /tracking system.

    Both are easy, and...
  27. Thread: Work phones

    by OuTcAsT
    Replies
    15
    Views
    1,005

    Just hooked me and all my guys up with Verizon...

    Just hooked me and all my guys up with Verizon Droid...Very good for our type of work.
  28. Replies
    13
    Views
    1,359

    I do: Dispatching Tech Support Customer...

    I do:

    Dispatching
    Tech Support
    Customer Service
    Order all parts
    Estimates to customers
    And go into the field for "quality assurance" checks.

    And if we get really busy...I can still turn...
  29. Replies
    68
    Views
    2,944

    Do you have credit accounts at parts houses ? ...

    Do you have credit accounts at parts houses ?
    Do you have credit accounts at equipment distributors?
    Do you have a contractors license in your State?
    Can you afford General liability insurance?...
  30. Replies
    10
    Views
    703

    Poll: "mountain-oysters" ? :couch:

    "mountain-oysters" ? :couch:
  31. Quite frankly...Yes. My insurance works fine the...

    Quite frankly...Yes. My insurance works fine the way it is.
  32. Replies
    5
    Views
    1,089

    Looking at the wiring diagram, it does indeed...

    Looking at the wiring diagram, it does indeed seem that the contactor coil could be the problem, or some sort of short or grounding between the two.
  33. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    Looks like he's in Cleveland there y7, our guys...

    Looks like he's in Cleveland there y7, our guys are in Boston, and yeah, they're out due to snow.
  34. Replies
    5
    Views
    1,089

    A model number would help greatly !

    A model number would help greatly !
  35. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    LOL...they were just stuck in there, we did...

    LOL...they were just stuck in there, we did install 90's and turn them around later that day.
  36. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    I did not design the unit, would have to consult...

    I did not design the unit, would have to consult York/ JCI on that one...
  37. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    Yes, pretty much all of them have Savvy...

    Yes, pretty much all of them have Savvy w/ethernet now, we've changed quite a few.
  38. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    The Novar controls network all the RTU's...

    The Novar controls network all the RTU's together, and back to a computer interface (Savvy, or Executive controller) They have a discharge air temperature sensor in each unit, and a space sensor in...
  39. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    Correct, the disconnect IS built in, and the...

    Correct, the disconnect IS built in, and the thermostat wire is not in the same pull box, the sensor wires for the NOVAR controls are in the unit, and the space sensor comes up thru the bottom. The...
  40. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    cool, where are you from, if I might ask? ...

    cool, where are you from, if I might ask?



    That's why I posted it...you got a beef? let's hear it !
  41. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    It is rare in our particular location....but when...

    It is rare in our particular location....but when it does, the rednecks are lost ! LOL
  42. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    I agree, and as soon as we thaw a bit, I will be...

    I agree, and as soon as we thaw a bit, I will be constructing proper traps, thanks for the input!
  43. Replies
    123
    Views
    31,278

    ^^ This sums up my position exactly, if you can't...

    ^^ This sums up my position exactly, if you can't take pride in ALL of your work...why bother?
  44. Replies
    18
    Views
    3,702

    This is exactly why we went to strictly...

    This is exactly why we went to strictly commercial/industrial,
    way too many hacks in residential.
  45. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    No, we still have some touch up to do, but it's...

    No, we still have some touch up to do, but it's hard to glue PVC at 22 degrees !
  46. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    Actually, I usually do not use flex lines, these...

    Actually, I usually do not use flex lines, these however were extremely nice stainless steel, and coated with stainless mesh, This is a test case to see how well they hold up, and time was very...
  47. Thread: RTU Changeouts

    by OuTcAsT
    Replies
    33
    Views
    4,494

    RTU Changeouts

    We changed out several old Lennox units and installed some York units and curb adapters, what say ye ?

    http://i875.photobucket.com/albums/ab312/dbruner/2010-02-02132719.jpg...
  48. Thread: pic test

    by OuTcAsT
    Replies
    0
    Views
    369

    pic test

    http://i875.photobucket.com/albums/ab312/dbruner/2010-02-02132719.jpg
  49. Thread: How Beer Works

    by OuTcAsT
    Replies
    3
    Views
    1,839

    waking up with her in the morning!!! :eek:

    waking up with her in the morning!!!

    :eek:
  50. Replies
    2
    Views
    1,428

    Um...exactly WHICH shorts were you checkin'...

    Um...exactly WHICH shorts were you checkin' out?:confused: