Search:

Type: Posts; User: Rookie2dafield

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    511

    Goodman coated coils

    We have had alot of coil leaks due Formicary corrosion, carrier now has tin platted coils, goodman has some kind of black coating, with these new goodman coils some sort of algae grows in the drain...
  2. Replies
    28
    Views
    2,084

    is there no limit

    Is there a limit to how much an employer can make you work. is anyone else being worked and pushed to hard.
  3. Replies
    8
    Views
    804

    looking for a new tool

    my work gives me $200 a year for tool replacement and repairs.
    looking for some ideas. I don't have anything I really need but its either use it or lose it, plus I'm a tool junkie and I'm always...
  4. Replies
    4
    Views
    821

    I wish I hadn't watched that, Now I have to go...

    I wish I hadn't watched that, Now I have to go buy one and I have a feeling its not going to be cheap.
  5. If its a recip comp. with a txv it needs a start...

    If its a recip comp. with a txv it needs a start kit.

    also if the outdoor unit is a GSH13036 or GSC13036 with a 20 amp breaker it needs a start kit. or up size breaker to 25 amp hvac breaker
  6. I would suggest hallmark or Airtron. Both good...

    I would suggest hallmark or Airtron. Both good and honest
  7. Replies
    8
    Views
    685

    We had a neighborhood get hit by lightning and...

    We had a neighborhood get hit by lightning and killed all the blower motors.

    I think it came out to be about 30 in all, their was another company out as well that got the rest.

    Worst part was...
  8. :eek:Wow that has got to be the must unforeseen...

    :eek:Wow that has got to be the must unforeseen problem I have ever heard. I hope you didn't pull all your hair out on that one. :confused:I kept racking my brain trying to think of what else could...
  9. if the compressor is pumping like you say it is I...

    if the compressor is pumping like you say it is I don't think that is the problem.
    sounds like a bad rev valve. I had the same problem and that was the cause.
    but two bad rev valve in a row that is...
  10. why did they have to replace their unit. Centex...

    why did they have to replace their unit. Centex has two year Warranty parts and labor. so it should have been taken care of at no cost. I don't see any reason that they would have to replace the...
  11. I'm in S.A. Who is your builder. We do the...

    I'm in S.A.

    Who is your builder. We do the majority of new installs in San Antonio and surrounding areas.

    Centex is the only one I can think of that installs electic heat. But they do offer...
  12. Replies
    3
    Views
    690

    On the carrier 4 and 5 don't do anything change...

    On the carrier 4 and 5 don't do anything change to 3 for high 2 med 1 for low
    not sure if its the same for Trane
  13. how far back do you set your t-stat. If its 95...

    how far back do you set your t-stat. If its 95 outside and you let it get 80 then want it to cool to 73 its ganna take a while. I would suggest not setting your t stat back more than a few degrees....
  14. Thread: coil

    by Rookie2dafield
    Replies
    11
    Views
    1,009

    If I connect a yellow and a blue Interconnecting...

    If I connect a yellow and a blue Interconnecting single pole connector does that make green.
  15. sounds like the rev valve to me. but without...

    sounds like the rev valve to me. but without being there can't say for sure. that may have been what took out the last comp. Is this a heat pump.
  16. Replies
    5
    Views
    1,022

    :eek: sweet I'll take 2

    :eek: sweet I'll take 2
  17. Replies
    24
    Views
    1,997

    Is it alright to leave a suction line drier in...

    Is it alright to leave a suction line drier in for 3 weeks. I was under the impression 72 hours max.
  18. Just saw your post the two I had were goodman as...

    Just saw your post the two I had were goodman as well. I wonder if they are having problems with there valves. I wonder if dryheat122 has a goodman too.
  19. just my 2 cents

    I disagree with the fact that a stuck rev valve will have a diff in pressure that will show on gauges. The last two I have seen had no diff. Comp was pumping to rev valve to accumulator back to...
  20. Replies
    48
    Views
    3,205

    I don't think that compressor is bolted down. the...

    I don't think that compressor is bolted down. the weight of the compressor would be enough to twist the line like in the picture. Looks like The compressor slid down to the bottom right of pic and...
  21. Replies
    39
    Views
    11,088

    I did try and understand I went to your site but...

    I did try and understand I went to your site but I still have concerns about the chlorine. yes it can solve issues with drain clogs I don't argue with that. I just have concerns about chlorine...
  22. Replies
    39
    Views
    11,088

    I just got the ACME roller skates, Iron bird...

    I just got the ACME roller skates, Iron bird seeds and super magnet that road runner is as good as mine. oh yea and it was cheaper than the Al G LEMON maker. I think i will avoid putting chlorine...
  23. Replies
    39
    Views
    11,088

    I was duped into reading a infomercial I feel...

    I was duped into reading a infomercial I feel violated:eek:
    I could hear the Oxi clean guy in my head as I read this.

    I wonder if you drain line leads to your bathroom sink if you get a nice...
  24. Replies
    63
    Views
    4,236

    hey you got over 15 post why don't you apply for...

    hey you got over 15 post why don't you apply for pro membership
  25. Replies
    63
    Views
    4,236

    rig it so your ac runs non stop and when in door...

    rig it so your ac runs non stop and when in door temp gets below your set temp your heat strips come on so it doesn't get to cold.

    but seriously the best thing would be to get a good tech out...
  26. Replies
    63
    Views
    4,236

    Are you trying to get pro member ship with all...

    Are you trying to get pro member ship with all these post in one thread
    Sq. Footage has little to do with tonage in humid climates.

    you can not tell if his AC is oversized by info he has stated....
  27. Replies
    14
    Views
    2,212

    I have never had to use Dye. My leak Det. finds...

    I have never had to use Dye. My leak Det. finds 99.9% of leaks and a isolation test, sheet rock knife and soap bubbles find the rest. I would like to try that stuff just to see how well it works and...
  28. Replies
    17
    Views
    1,051

    How Often do you air out your house. Indoor air...

    How Often do you air out your house. Indoor air quality is usually worse than out door due to all the chemicals we use in our house. Think about dish washing detergent that stuff gets steamed right...
  29. Replies
    33
    Views
    4,738

    I say it would depend on the conditions and type...

    I say it would depend on the conditions and type of metering device. Are we talking about a txv or a piston for a metering device.

    Lets take a Goodman with a piston with 60 outdoor temp and 85...
  30. Replies
    33
    Views
    4,738

    A compressor can’t compress a liquid. But many...

    A compressor can’t compress a liquid. But many have died trying.

    do you exert more energy moving your hand threw air(GAS) or water(LIQUID).
  31. Replies
    33
    Views
    4,738

    Why would you think it would go down. Higher...

    Why would you think it would go down. Higher pressure and its trying to compress liquid the compressor is screaming for help.
  32. I have a battery powered Bacharach h-10 can find...

    I have a battery powered Bacharach h-10 can find R-22 leak in a tornado and can pinpoint 410a with a little patience. I also have the plug in Mars H10 which I think was the company before Bacharach....
  33. I agree 100% Best of both worlds EAC + MEDIA

    I agree 100% Best of both worlds EAC + MEDIA
  34. Replies
    33
    Views
    4,738

    You are flooding the evaporator little amount of...

    You are flooding the evaporator little amount of refrigerant is evaporating which means you are not absorbing as much latent heat (which is the most efficient way to absorb heat). Less heat = colder...
  35. Replies
    27
    Views
    2,676

    I think adding a mini split is your best bet....

    I think adding a mini split is your best bet. Ceiling fans do help move air and make a room seem cooler but the motor in the fan adds to the overall heat load. May want to look into solar screens if...
  36. if your putting bleach or other chemicals down...

    if your putting bleach or other chemicals down the drain to clean it you might have more rust than normal. the coil is copper and aluminum and will not rust but the end plates and screws will. With...
  37. Replies
    190
    Views
    8,252

    Major Payne the best dam movie ever Bubba you...

    Major Payne the best dam movie ever

    Bubba you aint got no legs, want me show you little trick take your mind off that pain soldier

    tooot toot
  38. Replies
    9
    Views
    741

    I have been with this company for three years and...

    I have been with this company for three years and this is the slowest it has ever been. 25-30 hours a week for the last month or two. were the hell is global warming when you need it.
  39. Replies
    5
    Views
    708

    what do you have to do get a tour of the factory.

    what do you have to do get a tour of the factory.
  40. yes

    yes
  41. This Will ansewer all your ? Basic...

    This Will ansewer all your ?


    Basic Refrigeration & Charging Procedures Interactive CD-rom

    http://www.licensedelectrician.com/Store/ES/RCP.htm
  42. Replies
    21
    Views
    1,805

    I may have bought it

    I may have bought it
  43. Replies
    21
    Views
    1,805

    the split has alot to do with RH% and air flow. I...

    the split has alot to do with RH% and air flow. I don't think one can say what a split should be with out checking Static Pres. cfm, wet and dry bulb.

    laten heat is being removed but will not show...
  44. Replies
    15
    Views
    1,034

    this may not be DSS. DSS is caused by bacteria...

    this may not be DSS. DSS is caused by bacteria building up on the evap coil when AC is not being used then when either ac comes on or unit goes into defrost the coil gets cold and wet and bacteria...
  45. Replies
    9
    Views
    920

    I don't think you can say one way or the other...

    I don't think you can say one way or the other until you check the system for yourself. Find out why it needs the start kit to run. Does it have a txv and a recip comp. or an undersized breaker....
  46. Replies
    27
    Views
    1,646

    I have a 3.2 amp low voltage breaker that you can...

    I have a 3.2 amp low voltage breaker that you can reset, but most of the time I just use a good old ohm meter.
  47. Replies
    118
    Views
    15,156

    :eek:I can't find any info on robinair digital...

    :eek:I can't find any info on robinair digital gauges other than they are Efficient Accurate and dependable. and the ad is just teasing me in the corner of my screen as I type this. :mad:
  48. Replies
    31
    Views
    2,151

    "I'm suggesting he get someone local to come look...

    "I'm suggesting he get someone local to come look at it"



    this sounds like a good idea
  49. Replies
    6
    Views
    491

    Why???

    Why???
  50. Replies
    6
    Views
    491

    all the info you need should be in the kit and on...

    all the info you need should be in the kit and on the unit to find the size you need.

    repost this in pro forum with a little more info. Make and model, elevation what coversion kit are you using. ...
Results 1 to 50 of 127
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event