Search:

Type: Posts; User: ctcont

Search: Search took 0.02 seconds.

  1. Replies
    25
    Views
    4,589

    Top shelf air handler

    That is a top shelf air handler
  2. Replies
    18
    Views
    4,535

    I can remember those days, i could not fail my...

    I can remember those days, i could not fail my old man would kick my ass into next year, so i had to study harder and party haeder in dhort bursts, the memories.
  3. Replies
    16
    Views
    4,178

    Are you a tech or home owner?

    Are you a tech or home owner?
  4. Thread: HOT DAWG !!!

    by ctcont
    Replies
    6
    Views
    2,571

    The papers that come with the unit should be read...

    The papers that come with the unit should be read and u derstood by the installing party or you get this, i like it space saving desighn
  5. Replies
    11
    Views
    2,829

    No air scoop no 12 inches before the scoop...

    No air scoop no 12 inches before the scoop accordimg to weil ,clain and dan holahan circulators on this style boiler should be on the supply also reccomend hangers, the coustomer probraly got what...
  6. Thread: 8 tons of fun!!

    by ctcont
    Replies
    24
    Views
    5,026

    No traps? Elecrtical shut offs? Zip tie tails ?

    No traps? Elecrtical shut offs? Zip tie tails ?
  7. Replies
    43
    Views
    9,372

    I have done it i was in a company they purchased...

    I have done it i was in a company they purchased worked there for 2 years and left they pestered me and 3 othors for a few years to return to build up the service dept light commercial so i did it...
  8. Replies
    16
    Views
    4,178

    There is a way to better control humidity with a...

    There is a way to better control humidity with a standard system just use a 2 stage ac thermostat , y1 wire to med fan speed and y2 wire to high speed, use a txv and freezestat time delay and you...
  9. Replies
    16
    Views
    4,178

    Dont use that i have had trouble with it...

    Dont use that i have had trouble with it compressors grinding and 3 blown humidity not as well controled , i would use the infinity by carrier or the goodman amana brands they are bullet proof
  10. Replies
    6
    Views
    647

    I use plastic bunny ears on hanging my pex or i...

    I use plastic bunny ears on hanging my pex or i drill the holes larger than i need to always use an expansion loop . I have been insulating my pes lines and using a larger hanger over the insulation....
  11. Replies
    23
    Views
    1,876

    I would get away from oil and go with gas you...

    I would get away from oil and go with gas you will save alot of money put in a tankless navian water heater you will be happy
  12. Thread: Oldies A/C quiz

    by ctcont
    Replies
    43
    Views
    4,039

    Old ac units

    I have an old post office i have been servicing for years , same equipment keep them oiled clean work great after all these years one day they will replace them, you know how that goes
  13. Replies
    4
    Views
    1,609

    Duct less

    Nice job
  14. Replies
    13
    Views
    3,628

    Garage

    Interesting that would not fly in my neck of the woods
  15. Thread: spinning filter

    by ctcont
    Replies
    12
    Views
    2,575

    Filter

    I happen to run across that all to much, mostly homeowners trying to do it themselves
  16. Thread: Short Cycle

    by ctcont
    Replies
    10
    Views
    2,559

    Short cycle

    Thats the rapid dehumidity feature. Adds 2 seer to any system
  17. Replies
    22
    Views
    5,648

    Ducting

    Coustomer got shafted inspector got greased contractor has to sleep sometime
  18. Replies
    18
    Views
    3,398

    Homeowner special

    Talk about clip and play , puts a new thought on plug and play
  19. Replies
    16
    Views
    3,214

    Electric meter

    Thats a hack class job. Crapsman quality
  20. Replies
    24
    Views
    4,487

    boilers

    this is the mark of a true craftsman
  21. Replies
    14
    Views
    3,538

    furnace pictures

    nice work
  22. Replies
    5
    Views
    818

    williamson furnaces

    i recently pulled one out and the heat exchanger looked almost brand new the furnace was 60 years old the coustomers iol company got them to replace it, funny the coustomer did not use them great...
  23. Replies
    22
    Views
    9,733

    Copper lock

    I used this product for a place i could not get a torch into it held my 300 psig pressure test and evacuated to 50 microns . I followed the instructions generusly cleaned the fittings glued the pipe...
  24. Replies
    73
    Views
    14,916

    Grill

    I bought a tech grill infared type it is not cheap but lasts forever and cooks fast
  25. Thread: Mo betta

    by ctcont
    Replies
    11
    Views
    2,629

    Job

    It is always more interesting doing it after someone else tried keep your spirits high and after you are done with this job wait a month and go to aruba
  26. Replies
    37
    Views
    13,261

    Vans

    Niceclean fleet interesting store front how does that work out?
  27. Replies
    136
    Views
    26,475

    Vaccum

    I thought i was the only one like this nice to know i am not alone i tried one thing, i put it all together on a 1/2 plywood board except the pump used 1/4 copper tubing so i could plastic it ( yhe...
  28. Thread: School A/C job

    by ctcont
    Replies
    27
    Views
    5,192

    School

    Very nice job like one of the othor members mentioned this is a great example of true american craftsmanship i would only reccomend different unistrut clamps, but it is a great job keep up the great...
  29. Replies
    58
    Views
    9,591

    Good man

    Nice job there is alot goin on there i like the flex connecter here we have to hard pipe everything
  30. Thread: Condenser pumps

    by ctcont
    Replies
    27
    Views
    5,002

    Nice job

    I have done this when i was in the union fun heavy work nice spacing. Keep up the good work
  31. Thread: Some examples

    by ctcont
    Replies
    11
    Views
    2,297

    Dealership

    Very nice spiral work i am surprised they did radiant heating i have done a few dealerships only bmw and mercedes audi few othors did radiant i did our local toyota and they had all sorts of money...
  32. Replies
    13
    Views
    4,038

    Snake skin

    I am happy we dont encounter them up north we have our varmits but no snake i dont like them critters
  33. Replies
    25
    Views
    8,051

    True hackery

    I have seen this all to much in my neck of the woods do they also use line voltage thermostat with w-r jumped? Filter. Gas?
  34. Replies
    7
    Views
    1,249

    Try carmines 90 sand pit road danbury ct...

    Try carmines 90 sand pit road danbury ct 203-791-8089 get an application thet are a good company
  35. Replies
    25
    Views
    4,589

    Sheer hackery

    We have the same thing here bank paints over the mold and says its just alittle water damaged . Up here they like to put a hot water coil on top and pex it to the water heater with a 007 pump. Not...
  36. Replies
    170
    Views
    24,171

    Tools

    I got the testo set up i can do evacuations s/h s/c pressures temp microns had it for 11/2 years so far so good
  37. New home

    First and formost get it sprayfoamed will save you alot. , have an erv installed , go dual fuel 95% gas furnace and heat pump zone it if needed you will have the perfect home, reccomend uv light too...
  38. Replies
    2
    Views
    1,208

    Kitec pex

    I got about 20 rolls of 1/2 orange / blue mixture bunch of fittings 1203-994-9022. Dial any time
  39. Adjust your second stage on the thermostat that...

    Adjust your second stage on the thermostat that should fix that or add in the carrier auxillary heat lock out sets up as sens1
  40. Replies
    2
    Views
    1,208

    Kitec pex tubing

    We have a real overstock of kitec pex tubing 1/2-3/4-1 domestic and heat fittings buy excess i will give you the tools we slowed down i need the space
  41. Replies
    26
    Views
    7,739

    Carrier has a cross referance chart within their...

    Carrier has a cross referance chart within their commercial dept. Get basil on the phone
  42. Replies
    6
    Views
    1,351

    Make the return bigger use what the factory wants...

    Make the return bigger use what the factory wants i had the same problem on a account i took over that was my fix and i also used the factory tech support
  43. You need to do a load calc on the conditioned...

    You need to do a load calc on the conditioned space first, if the load is 3 tons get a 3 ton condenser afterall hopefully you did not do it wrong the first time it will help them with humidity...
  44. Replies
    6
    Views
    1,957

    Do not use a water softener it WILL make tour...

    Do not use a water softener it WILL make tour problem worse, we use honeywell true steam they reccomend the following
    1. Use cold water unsoftened provide minimun of 10 micron filter oversize filter...
  45. Replies
    4
    Views
    604

    My mechanic always told me You have 2 eyes one...

    My mechanic always told me You have 2 eyes one mouth 2 ears. Get the equasion? That quote i pass on to my apprentices
Results 1 to 45 of 45