  1. Replies
    8
    Views
    1,185

    where im from we use threaded rod to support the...

    where im from we use threaded rod to support the unit.....love the chain
  2. Replies
    6
    Views
    420

    the fill valve will automatically keep the boiler...

    the fill valve will automatically keep the boiler pressure at 12 lbs at least b&g valves do,too much pressure will cause relief valve to pop,you need a tech!
  3. Replies
    21
    Views
    3,031

    were forgetting something in this box,ah screw it...

    were forgetting something in this box,ah screw it who needs a disconnect tie the wires together and let someone be suprized or zapped:eek:
  4. I've run into several bradford-white units like...

    I've run into several bradford-white units like this myself. had plenty of problems with bradford-white recently usually the sealed burner compartment style, replaced many gas valves on these units;)
  5. what part of the chicago burbs are you from, i...

    what part of the chicago burbs are you from, i also work in the n/w suburbs of chicago?
  6. at least they used unistrut,and its supported so...

    at least they used unistrut,and its supported so well:eek: thats really bad good luck with that mess
  7. Replies
    14
    Views
    3,145

    my dumba$$ company would quote a new unit and put...

    my dumba$$ company would quote a new unit and put it the same spot :D
  8. they say your a goodman dealer diceman if so you...

    they say your a goodman dealer diceman if so you seem to the right person to ask, so is what there telling me at tech support seem right??? model#gmpn100-4 and year of furnace is 1999
  9. yeah, I did think of that so I already shortened...

    yeah, I did think of that so I already shortened the tube and made sure there was no belly in the tube to hold water
  10. Replies
    20
    Views
    5,166

    solder probably weighed more than the valve your...

    solder probably weighed more than the valve your holding
  11. looking for an answer..for goodman junk

    I was recently on a service call, it was a sunday night overtime call on a goodman high eff. furnace. cust. was gone all day and when they got home the furnace was out. of course it was -4 here in...
  12. Replies
    40
    Views
    12,659

    Dangerous is an understatement the pilot flame...

    Dangerous is an understatement the pilot flame also gives off c.o gas which is the reason for the hood w/tube lucky someone wasn,t killed by the looks of that unit, that kind of stuff makes real...