    Great question But if you think about it, if the...

    Great question
    But if you think about it, if the latent load is high and you slow the fan down the evaporator temperature does not drop.as fast as when the latent load is low because more of the...
  2. Replies
    13
    Views
    2,055

    Rick, Yes. QwikSEER+ will handle the change...

    Rick,

    Yes.
    QwikSEER+ will handle the change in latent/sensible loading automatically. You see when there is more latent load, it can slow the fan down more (without a significant drop in coil...
  3. Replies
    13
    Views
    2,055

    Rick, We are actually not trying to hold the...

    Rick,
    We are actually not trying to hold the evaporator temperature constant, rather we are minimizing the power consumption. The heat removed by the evaporator will always match the heat carried...
  4. Replies
    13
    Views
    2,055

    Mark, Actually, the QwikSEER+ board is very...

    Mark,

    Actually, the QwikSEER+ board is very different from a product such as the Fan Handler or the ICM CC750. These devices, (both ICM CC750 and Fan Handler) are variable speed drives that...
  5. Replies
    13
    Views
    2,055

    Rick, This is Bob Scaringe from Mainstream...

    Rick,
    This is Bob Scaringe from Mainstream Engineering the maker of all QwikProducts including the QwikSEER+. Basically what we are doing with the QwikSEER+ is a poor-mans version of a continually...
  6. Replies
    51
    Views
    5,598

    Rubbing alcohol has lots of water in it so in...

    Rubbing alcohol has lots of water in it so in addition to being flammable it also adds water into the line set making evacuation slower
  7. Replies
    51
    Views
    5,598

    No Qwik System Flush will not bother the...

    No Qwik System Flush will not bother the reversing valve
  8. Replies
    51
    Views
    5,598

    Great You will also find it cost quite a bit...

    Great
    You will also find it cost quite a bit less money which is aways good
    Bob
  9. Replies
    51
    Views
    5,598

    Yes We also make the QwikLug terminal repair...

    Yes
    We also make the QwikLug terminal repair kit, QwikCheck acid test kit, QwikShot acid treatment, a mold test kit and a bunch more.
    I think you will find the System flush works better than...
  10. Replies
    51
    Views
    5,598

    Bill I will send out a starter kit on Monday...

    Bill
    I will send out a starter kit on Monday
    Please let me know your thoughts after using it.
    Bob
  11. Replies
    51
    Views
    5,598

    Wish you would try QwikSystemFlush in the orange...

    Wish you would try QwikSystemFlush in the orange aerosol can. Independent tests show it works better and it cost quite a bit less! Send my your work address and I will send you a can to try for...
  12. Replies
    51
    Views
    5,598

    Let's be clear, I am not talking about any...

    Let's be clear, I am not talking about any flushing product except ours but if any manufacturer has any data to show QwikSystemFlush leaves a residue then I would like to see that data published so...
  13. Replies
    51
    Views
    5,598

    This is a great question. Look if the compressor...

    This is a great question. Look if the compressor manufacturers find any brand of flushing solution in their compressor they will invalidate the warrantee and they should since a flushing agent will...
  14. Replies
    51
    Views
    5,598

    As the manufacturer of QwikSystemFlush I will...

    As the manufacturer of QwikSystemFlush I will tell you if you have the time to do this it will certainly clean the lines but you have to recover and recycle the cleaning refrigerant and discard both...
  15. Thread: Acid-Away

    by Bob_Scaringe
    Replies
    30
    Views
    3,189

    QwikShot acid treatment works for all oils and...

    QwikShot acid treatment works for all oils and refrigerants since it just accelerates the transport of the acid to the filter drier instead of neutralizing the acid. This is because the...
  16. Replies
    9
    Views
    707

    Just so you know there is no alcohol of any type...

    Just so you know there is no alcohol of any type in QwikSystemFlush and of you check out the independent test results done by both a university and a testing lab they both show that it is better at...
  17. Alcohol is a cosolvent and will remove water but...

    Alcohol is a cosolvent and will remove water but most alcohols are not 100% (200 proof) but are diluted with water, even the denatured alcohols. Much better off using a flushing product and Qwik...
  18. Replies
    1
    Views
    495

    Condenser pads

    Anyone have trouble with the local building department when using prefabricated pads?
  19. Replies
    20
    Views
    3,311

    I am not going to try and convince you that...

    I am not going to try and convince you that QwikChecks work because your mind is made up but I will give you some science. There are two types of acid: Organic (which are mild) and are always present...
  20. Replies
    135
    Views
    21,404

    Anyone who puts that stuff in a system is crazy...

    Anyone who puts that stuff in a system is crazy
    Those sealers fall into two categories the automotive sealers swell the o rings to seal the IMACA fittings on the car and the HVAC leak sealers form a...
  21. Replies
    51
    Views
    5,598

    I would not put that stuff on your hands or...

    I would not put that stuff on your hands or breathe the vapors
    Read the MSDS
  22. Replies
    24
    Views
    3,174

    No issues same stability limits as POE or...

    No issues same stability limits as POE or refrigerants
  23. Replies
    6
    Views
    666

    Thanks for the input

    Thanks for the input
  24. Thread: Freon

    by Bob_Scaringe
    Replies
    29
    Views
    4,344

    Actually 410A is a better choice. It is a...

    Actually 410A is a better choice. It is a azetropic blend so it behaves a a single fluid meaning it can be topped off and it provides higher efficiency. However, it requires a larger condenser and...
  25. Replies
    24
    Views
    3,174

    Yes, But do not add it to the system until after...

    Yes, But do not add it to the system until after it is charged. If the compressor has a crankcase heater operate that during evacuation and perform a triple evacuation before charging. After the...