  1. Replies
    6
    Views
    423

    I had issues logging into certain jobs using...

    I had issues logging into certain jobs using workbench but
    I found out that there were a.jar files installed on the jace
    that were not installed on my laptop.
    Check the a.jar files through the...
  2. Thread: JCI LON

    by jaceski
    Replies
    2
    Views
    309

    JCI LON

    I have a site that has JCI LN series lon controllers with FX60.
    I am told the only way to program them is with LN Builder,
    which is JCI branch only.
    Using FX workbench, can I use distech plugins?...
  3. Replies
    12
    Views
    961

    Under the point, Did you actually select Hex and...

    Under the point, Did you actually select Hex and put in 10 for address or 0A?

    How do you write to it?
  4. Replies
    12
    Views
    961

    Thanks for the feedback...I built out the temp...

    Thanks for the feedback...I built out the temp points as Numeric bits and beginning bit 0 and number of bits 8 for Low Bytes
    and Numeric bits and beginning bit 8 and number of bits 8 for High Bytes...
  5. Replies
    12
    Views
    961

    429401 Here is the manual if it helps...modbus...

    429401

    Here is the manual if it helps...modbus towards the back.
  6. Replies
    12
    Views
    961

    ANYONE??

    ANYONE??
  7. Replies
    12
    Views
    961

    Anyone get these resolved? I have the same...

    Anyone get these resolved?
    I have the same issues with those points.

    I mapped the supply temp as Numeric Bit point as Hex 0 with
    Beginning Bit 0 and number of bits 8 then I did the conversion...
  8. Thread: Trane

    by jaceski
    Replies
    2
    Views
    341

    Trane

    Where do I get the latest MP580s firmware upgrade?
    I think it is 4.08, the latest?

    TIA
  9. Replies
    7
    Views
    913

    rgcowie4D: We are a contractor in Chicagoland...

    rgcowie4D: We are a contractor in Chicagoland area and we have the JCI tools along with some ex-JCI techs.
    We have ex-JCI customers that have ADS, NAEs, and just picked up a JCI customer that has...
  10. Replies
    17
    Views
    1,675

    I have old Lieberts(1996) that are wired back to...

    I have old Lieberts(1996) that are wired back to a sitelink panel that failed. This panel goes to a JCI N2 Integrator.
    The communication wires are on terminals 77 and 78 and go to this sitelink...
  11. Replies
    5
    Views
    440

    There are no numbers except the assembly number....

    There are no numbers except the assembly number.

    There are around 12 Liebert units connected to this panel then the JCI Integrator is connected to it.

    The Integrator is bad but there is a Jace...
  12. Replies
    5
    Views
    440

    Liebert Integrator

    Does anyone know what this Liebert panel is?

    The N2 Integrator is connected to it but the Integrator
    is bad and I want to connect to a Jace.

    366951366961366971
  13. Sounds like the firewall is blocking port 80 The...

    Sounds like the firewall is blocking port 80
    The Bacnet /IP 47808 should only need to be open if your network
    is talking to another external network. (Other side of firewall)
  14. Replies
    10
    Views
    804

    Here is one company.... ...

    Here is one company....

    http://www.dnvkema.com/

    They get paid through the Utility companies, not the customer.
  15. Replies
    273
    Views
    37,110

    Whatever anyone has is appreciated...

    Whatever anyone has is appreciated...
  16. try pinging the ip locally.

    try pinging the ip locally.
  17. i had a couple of pneumatic tube connections on...

    i had a couple of pneumatic tube connections on the box cracked, causing airflow to be intermittent.
  18. Replies
    16
    Views
    2,206

    check object category then uninstall JAVA and...

    check object category then uninstall JAVA and re-install the "old"
    version of JAVA that is needed.
  19. Replies
    9
    Views
    780

    what is in hand?

    what is in hand?
  20. Replies
    10
    Views
    804

    There are companies that will perform the audits...

    There are companies that will perform the audits free of charge..
  21. Replies
    10
    Views
    750

    You can use lonmaker to setup the network and...

    You can use lonmaker to setup the network and install .xif files in nae
  22. Replies
    273
    Views
    37,110

    Can you send me the link also?

    Can you send me the link also?
  23. Thread: FX Lon

    by jaceski
    Replies
    2
    Views
    525

    Thanks, I will try it and let you know.

    Thanks, I will try it and let you know.
  24. Thread: FX Lon

    by jaceski
    Replies
    2
    Views
    525

    FX Lon

    I have a site that has FX60 with NXP-FSC-01 lon controllers.
    One of the controllers died and we replaced it.
    I tried to discover the new device but the FX would not discover it.
    I connected to the...