    I took the evap out yesterday and cut out header...

    I took the evap out yesterday and cut out header to access all orfices and cleaned with small wire and used nitrogen! I will install Evap Monday and hope all is good. Lots of work and I took lots of...
  2. Replies
    11
    Views
    535

    I was charging a Rheem yesterday and same results...

    I was charging a Rheem yesterday and same results with adding two pounds but got readings with 85 degree house outside temp of 96 and gauges reading of 127.2 suction and 17.1 sh and 551.6 high side...
  3. Replies
    90
    Views
    25,380

    Guess we are going old school with this unit...

    Guess we are going old school with this unit meaning I have to pull out coil and get access to all orifices and blow them out with nitrozen then sweat them back in . Good news its only 100 and not...
  4. Replies
    90
    Views
    25,380

    I have the same problem with a carrier rooftop...

    I have the same problem with a carrier rooftop where the orifices are clogged and finding the parts to convert to a TXV isn't going well! I might have to remove and clean out each orifice like I did...
  5. Equalized system in twin reciprocating compressors in parallel

    What's the equalized system that is used when two reciprocating are in parallel? Is it internal,single pipe crank case,double pipe crankcase or discharge gas equalizer system?
  6. Using a larger filter drier and not adding refrigerant

    I was told that if you use a larger filter drier and not add refrigerant to compensate that the drier will act like a small evaporator! Has anyone heard of this or is this a myth?
  7. Replies
    24
    Views
    1,493

    Does soldering the cap tube to suction line

    Sub cool the liquid refrigerant? Took a class on friday and was told it increases effciency, prevents slugging and relives stress on the cap tube which I say that has no bearing on relieves stress on...
  8. Thread: Potential relay

    by bwd111
    Replies
    12
    Views
    630

    After speaking to former rses president and Norm...

    After speaking to former rses president and Norm Christopher I was told counter emf causes contacts of the potential relay to open
  9. Thread: Potential relay

    by bwd111
    Replies
    12
    Views
    630

    The operation of the potential relay is based on...

    The operation of the potential relay is based on the increase in back-electro-motive force (back-EMF) or a bucking voltage that is generated across the start winding as the motor increases in speed....
  10. Thread: Potential relay

    by bwd111
    Replies
    12
    Views
    630

    Potential relay

    What cause the contacts of the relay to open? Is it the counter EMF of the motor or current draw of the motor ?
  11. So it is the dome shell and not the compressor...

    So it is the dome shell and not the compressor inside the dome
  12. Debate on where the suction line discharges on a reciprocating compressor

    Is it the dome shell or compressor inside the dome?:gah:
  13. Replies
    2
    Views
    283

    Not trick question! Can test contacts if cold...

    Not trick question! Can test contacts if cold control is has correct
  14. Replies
    2
    Views
    283

    Cold control I think has lost its charge

    What are the results if a capillary of a cold control has lost its charge? Will the compressor not run or run continuously?
  15. Replies
    4
    Views
    442

    Determining factor in relay selecting

    Relay replacement what is the determing factor? Is it the system voltage or start and run current?
  16. When will a capacitor-start compressor fail to start?

    I know this is a basic question but cant remember if its when the cap is open,out of phase or shorted? I know you will hear a hum at times when the cap is bad but I was thinking when the cap is open...
  17. Seems like one but specs call for device that...

    Seems like one but specs call for device that control pressure
  18. What pressure controlled metering device operates

    in response to evap pressure? Is it a cap tube or txv or AEV
  19. Where should you check for subcooling of a domestic refrigerator ?

    or cant you check for subcooiling? Some people have told me between the condenser and the cap tube but then others have said you cant check for subcooling on a domestic refrigerator
  20. Needs some calc help on a pneumatics transmitter system

    I have a given transmitter and it has a range of 0 to 200 degrees. It maintains an output signal of 3 psig at 0 degrees and 15 psig at 200 degrees. What is the output change per unit of controled...
  21. Replies
    1,150
    Views
    124,548

    That's why I have everything delivered to my work...

    That's why I have everything delivered to my work cause there is always someone there to sign and receive the packages
  22. Replies
    1,150
    Views
    124,548

    I do a lot of selling on eBay and never have a...

    I do a lot of selling on eBay and never have a problem with USPS shipping to P.O box. FedEx won't ship to PO box.
  23. Replies
    1,150
    Views
    124,548

    Jim you know those test are hard and to only get...

    Jim you know those test are hard and to only get a plaque where's the wow factor! Give away a great prize with the award and people with talk and that is word of month which as you know the best kind...
  24. Replies
    1,150
    Views
    124,548

    I just bought one of those tvs at auction last...

    I just bought one of those tvs at auction last Saturday paid 250
  25. Replies
    104
    Views
    7,124

    Sounds great

    Sounds great
  26. Replies
    1,150
    Views
    124,548

    What if your working on a rooftop ? No shade no...

    What if your working on a rooftop ? No shade no shade
  27. Replies
    1,150
    Views
    124,548

    Give away a imanifold to the winner of the rses...

    Give away a imanifold to the winner of the rses imperial tool award!! Don't get cheap now. Don't get cheap
  28. Replies
    1,150
    Views
    124,548

    I totally agree

    I totally agree
  29. Replies
    1,150
    Views
    124,548

    Get an otter box case for the iPhone cause I know...

    Get an otter box case for the iPhone cause I know if that happens to me the phone is getting threw at a brick wall due to frustration.
  30. Replies
    1,150
    Views
    124,548

    Imperial should give the winner of the rses...

    Imperial should give the winner of the rses imperial award a imanifold!! That would be a great promotion
  31. Replies
    10
    Views
    925

    making a distibutor for a txv

    If the power goes out over night while vacuuming it could suck the vacuum oil into system causing contamination
  32. Replies
    84
    Views
    5,543

    Update on using 5ton compressor. The old...

    Update on using 5ton compressor. The old compressor was 7.5 and we replaced with 5 ton and used same txv used for 7.5 ton and also used 422d instead of r-22. The system works great as all was need...
  33. Replies
    84
    Views
    5,543

    Well it's locked out at 68. Quick question on new...

    Well it's locked out at 68. Quick question on new compressor. What is the line next to suction line on the compressor ? I have obviously suction and discharge but tube next to auction is that for...
  34. Replies
    84
    Views
    5,543

    Hope you learned something atleast. I did

    Hope you learned something atleast. I did
  35. Replies
    84
    Views
    5,543

    That was the complaint when those who are working...

    That was the complaint when those who are working out get to warm 64-62 was the preferred temp. I need a lock out temp of 68 max
  36. Replies
    84
    Views
    5,543

    Capacity and energy efficiency at low– and...

    Capacity and energy efficiency at low– and
    medium–temperature tends to be lower than
    HCFC-22. If the present R-22 system was
    at its maximum capacity during design
    conditions, additional capacity...
  37. Replies
    84
    Views
    5,543

    the new comp that is designed for r22 is charged...

    the new comp that is designed for r22 is charged with Poe oil. So I think the r422d will be just fine.
  38. Replies
    84
    Views
    5,543

    The 2nd compresser will hard let ever be used due...

    The 2nd compresser will hard let ever be used due to it never goes below 65
  39. Replies
    84
    Views
    5,543

    Yes

    Yes
  40. Replies
    84
    Views
    5,543

    That was his explanation but I am changing out...

    That was his explanation but I am changing out txv. The one compresser will take care of the heat load expect when exercise room is used and temp needs to get down to below 65.
  41. Replies
    84
    Views
    5,543

    Cause we installed another roof top 3 years ago...

    Cause we installed another roof top 3 years ago and there has been some remodel and this trane doesn't have the heat load that it use to. All this trane is for is a lunch room and an exercise room...
  42. Replies
    84
    Views
    5,543

    That I don't know. I have 3 other comps in the...

    That I don't know. I have 3 other comps in the roof that have been on r422d and they are still running great. I am going to open comp and see what the cause was
  43. Replies
    84
    Views
    5,543

    I reversed the leads with no result

    I reversed the leads with no result
  44. Replies
    84
    Views
    5,543

    Next question. The trane is a 7.5 ton comp and...

    Next question. The trane is a 7.5 ton comp and will be replaced with a 5 ton comp but boss says its ok to leave the txv and not replace. What is going to be the result with the second stage comp...
  45. Replies
    84
    Views
    5,543

    I'm with you on that except I charged the...

    I'm with you on that except I charged the compresser with r 422d last year and just bought a new jug as well.
  46. Replies
    84
    Views
    5,543

    Update on trane- I have Reversed the leads to see...

    Update on trane- I have Reversed the leads to see if that would free up comp also I have measure voltage from lead to lead to lead and get 480, I also hit the top of the dome with hammer and again...
  47. Replies
    84
    Views
    5,543

    They are side by side compressors feed off one...

    They are side by side compressors feed off one disconnect. I was going to take power from the running unit and connect to the other unit to see if power was an issue before I got deeper into cause. I...
  48. Replies
    84
    Views
    5,543

    I will try that and update on Monday morning.

    I will try that and update on Monday morning.
  49. Replies
    84
    Views
    5,543

    The compressor next to the one I am having...

    The compressor next to the one I am having problems with has the exact same voltage on each leg to ground and that one is running great. I wanted to compare voltage with the one that is running
  50. Replies
    84
    Views
    5,543

    Yes to ground

    Yes to ground
Results 1 to 50 of 760
Page 1 of 16 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards