    A thought..........

    A thought..........
  2. Replies
    0
    Views
    354

    Watch your back,safety!!!

    Lockout tagout tryout that's every tech or maintenance man been train everyday at work .A guy i work with today got the ride to ER.we think he may not able to use the right hand very much anymore...
  3. Replies
    6
    Views
    889

    R 22 Recycle ?..

    Went to supply to get R 22 paid 160 dollars more than 6 months ago! Question is I have half bottle dirty freon (R 22)been recover from jobs .can I double filter those into other recovery tank than...
  4. Replies
    3
    Views
    659

    Went back today got it level out it doing the job...

    Went back today got it level out it doing the job now .thanx for the input.owner said why level out now he has to buy a humidifier now. Funny guy .
  5. Replies
    45
    Views
    3,865

    Check for leaks .fan,blower,proper charge...

    Check for leaks .fan,blower,proper charge ,restriction any where?
  6. Replies
    45
    Views
    3,865

    Hmmm it didn,t sound...

    Hmmm it didn,t sound right!txv?:anyone::anyone::anyone::anyone::anyone:
  7. Replies
    36
    Views
    6,833

    I feed bad for the owner2 ,but don,t know why in...

    I feed bad for the owner2 ,but don,t know why in restaurant the unit wear out quick ,sounds like u may have to replace the unit .i just replaced the 7.5 ton Carrier roof top unit this morning still...
  8. Replies
    3
    Views
    659

    Rooftop unit installation ?

    Just replaced the existing carrier to thermo zone rooftop after got everything hookup everything ran fine on Ac, except did not see no water come out the drain pipe,took panel off find out the drip...
  9. Replies
    21
    Views
    1,560

    Right! single phase motor need more...

    Right! single phase motor need more booty!!!!:angel:
  10. Replies
    21
    Views
    1,560

    no load motor should draw less current ,every...

    no load motor should draw less current ,every motor should have the name plate ,it should tell u everything ,loose wire connection on 3 phase motor will not run,motor are protect by heater ,overload...
  11. been try many times use custom parts to make it...

    been try many times use custom parts to make it work, but in the long run find out the <some times the correct parts are cost less and get it done right !>worry free.