Search:

Type: Posts; User: Rhinohead

Page 1 of 8 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    2
    Views
    242

    Trutech order

    Can anyone check status #58710 placed 7.2, haven't got anyword.

    Sent from my SM-T230NU using Tapatalk
  2. Replies
    140
    Views
    3,170

    I like the shutdown growl,if that's what the...

    I like the shutdown growl,if that's what the topic was about? And it sucks on pump down refer units. But it's a paycheck . Overcome , conquer ,sleep , try again. We are guinea pigs

    Sent from...
  3. Replies
    28
    Views
    1,250

    He actually pulled charge weighed in new 410a ...

    He actually pulled charge weighed in new 410a before I could assist . It did improve some.

    Sent from my SM-T230NU using Tapatalk
  4. Replies
    28
    Views
    1,250

    It was doing about 1600 cfm of air. Flag on a 5...

    It was doing about 1600 cfm of air. Flag on a 5 ton. Original compressor was marble sounding barely pumping. Whole duct system was undersized , I went out with him today verified . Readings...
  5. Replies
    28
    Views
    1,250

    It's a 2 stage . Reverses in low stage I...

    It's a 2 stage . Reverses in low stage I believe

    Sent from my SM-T230NU using Tapatalk
  6. Replies
    28
    Views
    1,250

    Well it was a 5 ton. 410a. 60 psig. Don't...

    Well it was a 5 ton. 410a. 60 psig. Don't remember what failed originally . I never give that model compressor much thought because they fail. I thought airflow but that superheat had me...
  7. Replies
    28
    Views
    1,250

    Seems like a reading is off. But this guy doesn't...

    Seems like a reading is off. But this guy doesn't fake what he sees ,nothing adds up

    Sent from my SM-T230NU using Tapatalk
  8. Replies
    28
    Views
    1,250

    77 outdoor txv. 73 ret. Air Sent from my...

    77 outdoor txv. 73 ret. Air

    Sent from my SM-T230NU using Tapatalk
  9. Replies
    28
    Views
    1,250

    This phone call from my tech

    Replaced compressor on a evolution the 2 stage backwards bristol. So on start up he had 275 head with 13 degree subcool. 60 degree suction 12 degree superheat. 14 degree across evaporator....
  10. Thread: I don't know

    by Rhinohead
    Replies
    30
    Views
    1,359

    Still not a call back,after the repair I made. ...

    Still not a call back,after the repair I made.

    Sent from my SM-T230NU using Tapatalk
  11. Replies
    3
    Views
    441

    Had to say goodbye

    http://uploads.tapatalk-cdn.com/20160624/719103c766e035148b79569cadd5cbb3.jpg


    Sent from my iPhone using Tapatalk
  12. I had a thermal years ago that I loved until I...

    I had a thermal years ago that I loved until I loosened a fitting, took along time for rise to show up. Only thing I didn't like about it. I could hear air sucking in. Rate of rise. I thought ...
  13. Replies
    3
    Views
    610

    I think it's a carrier product , not sure. We...

    I think it's a carrier product , not sure. We have a lot of bryant out there .nice systems

    Sent from my SM-T230NU using Tapatalk
  14. Thread: I don't know

    by Rhinohead
    Replies
    30
    Views
    1,359

    Grab me a beer , I got an idea Sent from my...

    Grab me a beer , I got an idea

    Sent from my SM-T230NU using Tapatalk
  15. Thread: I don't know

    by Rhinohead
    Replies
    30
    Views
    1,359

    Love it. I thinking hillbilly engineering . New...

    Love it. I thinking hillbilly engineering . New capacitor thing ran fine

    Sent from my SM-T230NU using Tapatalk
  16. Thread: I don't know

    by Rhinohead
    Replies
    30
    Views
    1,359

    I don't know

    http://uploads.tapatalk-cdn.com/20160609/7e48a20e4625614b095ffadcb7e6ea88.jpg

    Sent from my SM-T230NU using Tapatalk
  17. Wanted a new stat. I hate to see the old stuff go away

    http://uploads.tapatalk-cdn.com/20160604/912bb32417f99d1d3ed6a5622a3d5359.jpg


    Sent from my iPhone using Tapatalk
  18. Replies
    21
    Views
    1,328

    Mucho too cold Sent from my iPhone using...

    Mucho too cold


    Sent from my iPhone using Tapatalk
  19. Replies
    17
    Views
    668

    Core driers might be crumbling . They are Sandy...

    Core driers might be crumbling . They are Sandy in a way when they come apart not unheard of for driers to do.

    Sent from my SM-T230NU using Tapatalk
  20. Replies
    4
    Views
    354

    Sounds like an overcharge of refrigerant . ...

    Sounds like an overcharge of refrigerant .

    Sent from my SM-T230NU using Tapatalk
  21. Replies
    21
    Views
    1,328

    Actually a Japanese steak house Sent from...

    Actually a Japanese steak house

    Sent from my SM-T230NU using Tapatalk
  22. Thread: Pizza Dough

    by Rhinohead
    Replies
    7
    Views
    2,953

    I'm hungry

    I'm hungry
  23. Replies
    21
    Views
    1,328

    ya oem. bout a year old. had a tecumseh in it.

    ya oem. bout a year old. had a tecumseh in it.
  24. Replies
    21
    Views
    1,328

    replaced start components, cleaned condesor. set...

    replaced start components, cleaned condesor. set it on normal
  25. Thread: Polar prince

    by Rhinohead
    Replies
    5
    Views
    333

    No it was raining but the original compressor ...

    No it was raining
    but the original compressor and fan were still running strong.

    Sent from my SM-T230NU using Tapatalk
  26. Thread: Polar prince

    by Rhinohead
    Replies
    5
    Views
    333

    You should see the capacitor Sent from my...

    You should see the capacitor

    Sent from my SM-T230NU using Tapatalk
  27. Thread: Polar prince

    by Rhinohead
    Replies
    5
    Views
    333

    Polar prince

    http://uploads.tapatalk-cdn.com/20160527/dffb419a9d6eaab6be409e0a0e4286ef.jpg

    Sent from my SM-T230NU using Tapatalk
  28. Replies
    21
    Views
    1,328

    How cold is too cold?

    http://uploads.tapatalk-cdn.com/20160527/5d004e03a8eff3320264c026806f884e.jpg

    Sent from my SM-T230NU using Tapatalk
  29. Replies
    69
    Views
    2,657

    We have that high hum. Low load a lot here in...

    We have that high hum. Low load a lot here in southern In. Seems to last longer than it used to. I usually try and sell whole house dehum. Then the problem corrects itself when the...
  30. Might be using it for dehumidification ? Sent...

    Might be using it for dehumidification ?

    Sent from my SM-T230NU using Tapatalk
  31. Replies
    8
    Views
    496

    Threshold as well , has to good and working ....

    Threshold as well , has to good and working . Turn down temperature in that area if you can outside the door . Steal some lipstick , paint the gasket surface , close the door then open will...
  32. Replies
    28
    Views
    1,658

    That's too funny Sent from my SM-T230NU...

    That's too funny

    Sent from my SM-T230NU using Tapatalk
  33. Thread: My New Van

    by Rhinohead
    Replies
    59
    Views
    4,851

    Great job. Can we see it next year? Sent...

    Great job. Can we see it next year?

    Sent from my SM-T230NU using Tapatalk
  34. Thread: Happy happy

    by Rhinohead
    Replies
    6
    Views
    747

    Well the bud light is all I've tried out so...

    Well the bud light is all I've tried out so far. Ole faithful . I'm buffing up on Jims videos


    Sent from my SM-T230NU using Tapatalk
  35. Replies
    69
    Views
    3,073

    Yes the micro channel coil got me on one couple...

    Yes the micro channel coil got me on one couple years ago in low ambient situation , those seem to be less forgiving.

    Sent from my SM-T230NU using Tapatalk
  36. Replies
    27
    Views
    2,081

    Seems the best choice, is a reliable service...

    Seems the best choice, is a reliable service company well stocked. Sad

    Sent from my SM-T230NU using Tapatalk
  37. Thread: Happy happy

    by Rhinohead
    Replies
    6
    Views
    747

    Happy happy

    http://uploads.tapatalk-cdn.com/20160409/30d643f67b5140db0fbf4ba9edde0ff2.jpg
  38. Replies
    23
    Views
    1,537

    Ask first if they are having any issues. Why...

    Ask first if they are having any issues. Why clean everything for nothing.click it on,touchy , feely. Can reveal

    Sent from my SM-T230NU using Tapatalk
  39. Hum terminal on the board? Should be with...

    Hum terminal on the board? Should be with communicating unit. You cold use g, if all else fails

    Sent from my SM-T230NU using Tapatalk
  40. Thread: Stumped

    by Rhinohead
    Replies
    33
    Views
    1,564

    How many fans? Rotation correct ? Sent from...

    How many fans? Rotation correct ?

    Sent from my SM-T230NU using Tapatalk
  41. Compressor may be on the out if Bristol ...

    Compressor may be on the out if Bristol


    Sent from my iPhone using Tapatalk
  42. Replies
    344
    Views
    23,382

    I'm hungry Sent from my LGL39C using Tapatalk

    I'm hungry

    Sent from my LGL39C using Tapatalk
  43. Replies
    30
    Views
    5,676

    635171 old school Sent from my LGL39C using...

    635171 old school

    Sent from my LGL39C using Tapatalk
  44. Analog meters, blew the fuse when you forgot to...

    Analog meters, blew the fuse when you forgot to switch back to volts

    Sent from my LGL39C using Tapatalk
  45. Replies
    7
    Views
    1,190

    Ya good stuff here's the original unit for the...

    Ya good stuff here's the original unit for the hussman 624621 Did you recognize the other case?

    Sent from my LGL39C using Tapatalk
  46. Replies
    7
    Views
    1,190

    624191 old unit. This is the other case 624531...

    624191 old unit. This is the other case 624531 they also have 6 old wooden walk ins, running on k body compressor good stuff here

    Sent from my LGL39C using Tapatalk
  47. Replies
    7
    Views
    1,190

    624011 current unit, 624021 old belt drive tag...

    624011 current unit, 624021 old belt drive tag they aren't sure why it was swapped out. Going by to check it again this morning, seems temp is controlled by pressure switch. Been running warm,there...
  48. Replies
    7
    Views
    1,190

    Hussman produce cooler

    Can anybody identify this, looking for btu rating. Gravity, forgot to measure length 623731 Hope picture loaded.

    Sent from my LGL39C using Tapatalk
  49. Replies
    13
    Views
    1,212

    Subcool sorry Sent from my LGL39C using...

    Subcool sorry

    Sent from my LGL39C using Tapatalk
  50. Replies
    13
    Views
    1,212

    On Bryant infinity, under service settings it has...

    On Bryant infinity, under service settings it has refrigerant charging where it goes to 100% for 30 minutes then you set school. I believe it stays until you cancel test

    Sent from my LGL39C using...
Results 1 to 50 of 382
Page 1 of 8 1 2 3 4