    York Display

    We had a York YCUL0036EC17 chiller that is about 3 yr. old. It lost the display so we had a controls company (name will not be mentioned here) come out and "repair" it after we checked all the...
  2. Replies
    17
    Views
    2,580

    Service bulletin

    I was informed by local Trane distributor that the only service bulletin was a "Replace on Fail" bulletin in regard to the blades. No brainer there, replace on fail, duh.
    LBB In Indiana
  3. Replies
    17
    Views
    2,580

    Same problem with RTAC

    Replacing 22 blades and several brackets this week for a customer on two RTAC chillers. Apx. 4 years old, blades coming apart, ruins brackets and blades. Trane was no help, and will not admit a...
  4. Replies
    9
    Views
    1,477

    Same problem

    Carrier Model 48TJF024-681-BA, Ser. 4902F92(XXXXX)
    Your post is very interesting. We have a commercial printing company with many Carrier rooftop units. On one of the newer units, we have had...
  5. Thread: Liebert

    by lynnbb1
    Replies
    17
    Views
    1,945

    I work on quite a few Deluxe 3 Lieberts. I am...

    I work on quite a few Deluxe 3 Lieberts. I am finding a high failure rate on the variable speed fan motors. They overheat (and I mean sizzling HOT, tags burnt off side of motors at various sites)and...
  6. Thread: York vs. Heil

    by lynnbb1
    Replies
    18
    Views
    3,421

    You will not be sorry with the Heil. Installed...

    You will not be sorry with the Heil. Installed many and it is a quality furnace with both the primary and secondary heat exchangers made of stainless steel with lifetime warranties. Very simple,...
  7. Replies
    21
    Views
    1,552

    If this is a Bard wall hung unit, that may be...

    If this is a Bard wall hung unit, that may be your problem. The three Bard units I service all have this problem. High head, no matter what you do. They barely are able to "hang in there" above 85...
  8. Replies
    7
    Views
    2,419

    RSI Corporation in New Jersey still handles parts...

    RSI Corporation in New Jersey still handles parts for Edpac.
    I have a customer that has an Edpac unit, still operable, but it is probably not same mod/ser.
    They were good units in their day, and...
  9. Replies
    3
    Views
    957

    With everything turned off in the mech room, do...

    With everything turned off in the mech room, do you still have a negative pressure/downdrafting? Can you feel any air flow out of the room at the doors? If so, why? Take a match and crack the doors...