  1. Replies
    108
    Views
    6,397

    We had a female working with us two year ago. She...

    We had a female working with us two year ago. She didn't know much about hvac/refrigeration but we took her along and help her out. She spended most of the day in the office doing paperwork, ebay and...
  2. Replies
    15
    Views
    1,327

    Sorry my brother, can't help you out. Have no...

    Sorry my brother, can't help you out.
    Have no clues of what ya talkin'bout..
  3. Replies
    15
    Views
    2,614

    Hey give them a break, people needs a/c and...

    Hey give them a break, people needs a/c and contractor needs money. Can't put the dam thing on the roof, too much work, cost more and less profit. Stick the dam thing anywhere, colleect your money...
  4. Replies
    26
    Views
    3,805

    D-TEK leakdetector run about $350

    D-TEK leakdetector run about $350
  5. Replies
    3
    Views
    1,054

    i think this is a cap tube system. if it is...

    i think this is a cap tube system.
    if it is loside should be around 18 to 20 psi and high side 170 to 180 depending on ambient.
  6. Replies
    20
    Views
    2,437

    Try R414b(HotShot). You don't need to change out...

    Try R414b(HotShot). You don't need to change out the txv. Really good stuff, I've been using it for five year now. It work great perfect replacement for all the other R12 replacement.
  7. Replies
    6
    Views
    1,495

    i ran into this type of problem b4. Tyler freezer...

    i ran into this type of problem b4. Tyler freezer w/remote condensing unit keep shutting down on oil pressure. turn out to be the float inside the oil seperator
  8. Replies
    8
    Views
    893

    i use it for a yes or no answer. condensing unit...

    i use it for a yes or no answer. condensing unit running or not running? other than that it just bull****ting.
  9. Thread: 409A ?

    by frozenhead
    Replies
    19
    Views
    1,705

    you just looking at your OT. charge it at 80% of...

    you just looking at your OT. charge it at 80% of your R12. head pressure will be a litte higher, but 409a work ok.
  10. Replies
    6
    Views
    1,140

    story too long dude

    story too long dude
  11. Replies
    10
    Views
    1,065

    you got an air sensing t-stat and a pumpdown...

    you got an air sensing t-stat and a pumpdown system i understand. if your t-stat are ever satisfied you could adjust your low pressure control to cut-in a little higher(60psi to 68psi but check your...